An approach for determining allowable between reagent lot variation

被引:19
作者
Lantman, Marith van Schrojenstein [1 ,2 ]
Cubukcu, Hikmet Can [3 ]
Boursier, Guilaine [4 ]
Panteghini, Mauro [5 ,6 ]
Bernabeu-Andreu, Francisco A. [7 ]
Milinkovic, Neda [8 ]
Brguljan, Pika Mesko [9 ]
Linko, Solveig [10 ]
Brugnoni, Duilio [11 ]
O'Kelly, Ruth [12 ]
Kroupis, Christos [13 ]
Lohmander, Maria [14 ]
Sprongl, Ludek [15 ]
Vanstapel, Florent [16 ]
Thelen, Marc [1 ,2 ]
机构
[1] Amphia Hosp, Result Lab Clin Chem, Breda, Netherlands
[2] Radboud Univ Nijmegen, Dept Lab Med, Med Ctr, Nijmegen, Netherlands
[3] Ankara Univ, Interdisciplinary Stem Cells & Regenerat Med, Stem Cell Inst, Ankara, Turkey
[4] Univ Montpellier, Dept Genet, Rare Dis & Personalized Med Rare Dis & Autoinflam, CHU Montpellier, Montpellier, France
[5] Univ Milan, Dept Biomed & Clin Sci Luigi Sacco, Milan, Italy
[6] Univ Milan, Res Ctr Metrol Traceabil Lab Med CIRME, Milan, Italy
[7] Hosp Univ Puerta Hierro, Serv Bioquim Anal Clin, Madrid, Spain
[8] Univ Belgrade, Fac Pharm, Dept Med Biochem, Belgrade, Serbia
[9] Univ Clin Resp & Allerg Dis, Dept Clin Chem, Golnik, Slovenia
[10] Linko Q Solut Helsinki, Helsinki, Finland
[11] Spedali Civil Brescia, Clin Chem Lab, Brescia, Italy
[12] Assoc Clin Biochemists Ireland, Dublin, Ireland
[13] Natl & Kapodistrian Univ Athens, Attikon Univ, Med Sch, Dept Clin Biochem,Gen Hosp, Haidari, Greece
[14] Sahlgrenska Univ Jukhuset, Reg Lab Med, Trollhattan, Sweden
[15] Hosp Kladno, Clin Lab, Kladno, Czech Republic
[16] Univ Hosp Leuven, Belgium & Dept Publ Hlth, Lab Med, Biomed Sci Grp, Leuven, Belgium
关键词
measurement uncertainty; measurement procedures; position paper; reagent-lot; LONG-TERM;
D O I
10.1515/cclm-2022-0083
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Clinicians trust medical laboratories to provide reliable results on which they rely for clinical decisions. Laboratories fulfil their responsibility for accurate and consistent results by utilizing an arsenal of approaches, ranging from validation and verification experiments to daily quality control procedures. All these procedures verify, on different moments, that the results of a certain examination procedure have analytical performance characteristics (APC) that meet analytical performance specifications (APS) set for a particular intended use. The APC can in part be determined by estimating the measurement uncertainty component under conditions of within-laboratory precision (u (Rw)), which comprises all components influencing the measurement uncertainty of random sources. To maintain the adequacy of their measurement procedures, laboratories need to distinguish aspects that are manageable vs. those that are not. One of the aspects that may influence u (Rw) is the momentary significant bias caused by shifts in reagent and/or calibrator lots, which, when accepted or unnoticed, become a factor of the APC. In this paper, we postulate a model for allocating a part of allowable u (Rw) to between-reagent lot variation, based on the need for long-term consistency of the measurement variability for that specific measurand. The allocation manages the ratio between short-term and long-term variation and indicates laboratories when to reject or correct certain variations due to reagent lots.
引用
收藏
页码:681 / 688
页数:8
相关论文
共 32 条
[1]   Failure of Current Laboratory Protocols to Detect Lot-to-Lot Reagent Differences: Findings and Possible Solutions [J].
Algeciras-Schimnich, Alicia ;
Bruns, David E. ;
Boyd, James C. ;
Bryant, Sandra C. ;
La Fortune, Kristin A. ;
Grebe, Stefan K. G. .
CLINICAL CHEMISTRY, 2013, 59 (08) :1187-1194
[2]   Sociodemographic Correlates of Clinical Laboratory Test Expenditures in a Major Canadian City [J].
Barber, Jocelyn ;
Guo, Maggie ;
Nguyen, Leonard T. ;
Thomas, Roger ;
Turin, Tanvir Chowdhury ;
Vaska, Marcus ;
Naugler, Christopher .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2017, 148 (01) :91-96
[3]   Performance specifications for measurement uncertainty of common biochemical measurands according to Milan models [J].
Braga, Federica ;
Panteghini, Mauro .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2021, 59 (08) :1362-1368
[4]   The internal quality control in the traceability era [J].
Braga, Federica ;
Pasqualetti, Sara ;
Aloisio, Elena ;
Panteghini, Mauro .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2021, 59 (02) :291-300
[5]   The utility of measurement uncertainty in medical laboratories [J].
Braga, Federica ;
Panteghini, Mauro .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2020, 58 (09) :1407-1413
[6]   Performance criteria for combined uncertainty budget in the implementation of metrological traceability [J].
Braga, Federica ;
Infusino, Ilenia ;
Panteghini, Mauro .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2015, 53 (06) :905-912
[7]  
Calleja John, 2008, Clin Biochem Rev, V29 Suppl 1, pS71
[8]  
CLSI, 2013, US EV REAG LOT VAR C
[9]  
CLSI, 2012, VER COMP PAT RES ON
[10]  
COTLOVE E, 1970, CLIN CHEM, V16, P1028