Screening Tool for Anxiety Disorders: Development and Validation of the Korean Anxiety Screening Assessment

被引:13
作者
Kim, Yeseul [1 ]
Park, Yeonsoo [2 ]
Cho, Gyeongcheol [3 ]
Park, Kiho [1 ]
Kim, Shin-Hyang [1 ]
Baik, Seung Yeon [2 ]
Kim, Cho Long [2 ]
Jung, Sooyun [1 ]
Lee, Won-Hye [4 ]
Choi, Younyoung [5 ]
Lee, Seung-Hwan [2 ,6 ]
Choi, Kee-Hong [1 ]
机构
[1] Korea Univ, Dept Psychol, 145 Anam Ro, Seoul 02841, South Korea
[2] Inje Univ, Clin Emot & Cognit Res Lab, Ilsan Paik Hosp, 170 Juhwa Ro, Goyang 10380, South Korea
[3] McGill Univ, Dept Psychol, Montreal, PQ, Canada
[4] Natl Ctr Mental Hlth, Dept Clin Psychol, Seoul, South Korea
[5] Hanyang Cyber Univ, Dept Adolescent Psychol, 220 Wangsimni Ro, Seoul 04763, South Korea
[6] Inje Univ, Dept Psychiat, Ilsan Paik Hosp, 170 Juhwa Ro, Goyang 10380, South Korea
关键词
Screening tool; Anxiety disorder; GAD; Item response theory; Validation; DSM-IV; SPECIFICITY; SENSITIVITY; PREVALENCE; INVENTORY;
D O I
10.30773/pi.2018.09.27.2
中图分类号
R749 [精神病学];
学科分类号
100205 ;
摘要
Objective This study evaluated the psychometric properties of the Korean Anxiety Screening Assessment (K-ANX) developed for screening anxiety disorders. Methods Data from 613 participants were analyzed. The K-ANX was evaluated for reliability using Cronbach's alpha, item-total correlation, and test information curve, and for validity using focus group interviews, factor analysis, correlational analysis, and item characteristics based on item response theory (IRT). The diagnostic sensitivity and specificity of the K-ANX were compared with those of the Beck Anxiety Inventory (BAI) and Generalized Anxiety Disorder 7-item scale (GAD-7). Results The K-ANX showed excellent internal consistency (alpha=0.97) and item-total coefficients (0.92-0.97), and a one-factor structure was suggested. All items were highly correlated with the total scores of the BAI, GAD-7, and Penn State Worry Questionnaire. IRT analysis indicated the K-ANX was most informative as a screening tool for anxiety disorders at the range between 0.8 and 1.6 (i.e., top 21.2 to 5.5 percentiles). Higher sensitivity (0.795) and specificity (0.937) for identifying anxiety disorders were observed in the K-ANX compared to the BAI and GAD-7. Conclusion The K-ANX is a reliable and valid measure to screen anxiety disorders in a Korean sample, with greater sensitivity and specificity than current measures of anxiety symptoms.
引用
收藏
页码:1053 / 1063
页数:11
相关论文
共 48 条
[1]   Understanding diagnostic tests 3: receiver operating characteristic curves [J].
Akobeng, Anthony K. .
ACTA PAEDIATRICA, 2007, 96 (05) :644-647
[2]   Understanding diagnostic tests 1: sensitivity, specificity and predictive values [J].
Akobeng, Anthony K. .
ACTA PAEDIATRICA, 2007, 96 (03) :338-341
[3]  
[Anonymous], 2012, MPLUS STAT ANAL LATE
[4]  
[Anonymous], 2013, DIAGNOSTIC STAT MANU, VFifth, P1000, DOI DOI 10.1176/APPI.BOOKS.9780890425596
[5]  
[Anonymous], ANXIETY ITS DISORDER
[6]  
[Anonymous], 1990, PSYCHOL BULL, DOI DOI 10.1037/0033-2909.107.2.238
[7]  
[Anonymous], KOR VERS GAD 7 PAT H
[8]  
[Anonymous], EPIDEMIOLOGICAL SURV
[9]  
[Anonymous], ETS RES B SERIES
[10]  
[Anonymous], 2014, ETS standards for quality and fairness