Effect of Tantalum Pentoxide Addition on the Radiopacity Performance of Bi2O3/Ta2O5 Composite Powders Prepared by Mechanical Milling

被引:3
作者
Lin, Hsiu-Na [1 ,2 ]
Lin, Chung-Kwei [1 ,3 ]
Chang, Pei-Jung [1 ,4 ]
Chang, Wei-Min [1 ,5 ]
Fang, Alex [6 ]
Chen, Chin-Yi [1 ,7 ]
Yu, Chia-Chun [1 ,8 ]
Lee, Pee-Yew [1 ,9 ]
机构
[1] Taipei Med Univ, Coll Oral Med, Res Ctr Digital Oral Sci & Technol, Taipei 110, Taiwan
[2] Chang Gung Mem Hosp, Dept Dent, Taipei 110, Taiwan
[3] Taipei Med Univ, Sch Dent Technol, Coll Oral Med, Taipei 110, Taiwan
[4] Natl Taipei Univ Technol, Grad Inst Mfg Technol, Taipei 111, Taiwan
[5] Taipei Med Univ, Coll Oral Med, Sch Oral Hyg, Taipei 110, Taiwan
[6] Texas A&M Univ, Dept Engn Technol & Ind Distribut, College Stn, TX 77843 USA
[7] Feng Chia Univ, Dept Mat Sci & Engn, Taichung 407, Taiwan
[8] Chang Gung Mem Hosp, Ctr Dent Technol, Taoyuan 333, Taiwan
[9] Natl Taiwan Ocean Univ, Dept Optoelect & Mat Technol, Keelung 202, Taiwan
关键词
bismuth oxide; tantalum pentoxide; high temperature metastable phase; mechanical milling; radiopacity; diametral tensile strength; setting time; biocompatibility; MECHANOCHEMICAL SYNTHESIS; BISMUTH; NANOPARTICLES; CYTOTOXICITY; CEMENT; CELLS; ER;
D O I
10.3390/ma14237447
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Among the various phases of bismuth oxide, the high temperature metastable face-centered cubic delta phase attracts great attention due to its unique properties. It can be used as an ionic conductor or an endodontic radiopacifying material. However, no reports concerning tantalum and bismuth binary oxide prepared by high energy ball milling and serving as a dental radiopacifier can be found. In the present study, Ta2O5-added Bi2O3 composite powders were mechanically milled to investigate the formation of these metastable phases. The as-milled powders were examined by X-ray diffraction and scanning electron microscopy to reveal the structural evolution. The as-milled composite powders then served as the radiopacifier within mineral trioxide aggregates (i.e., MTA). Radiopacity performance, diametral tensile strength, setting times, and biocompatibility of MTA-like cements solidified by deionized water, saline, or 10% calcium chloride solution were investigated. The experimental results showed that subsequent formation of high temperature metastable beta-Bi7.8Ta0.2O12.2, delta-Bi2O3, and delta-Bi3TaO7 phases can be observed after mechanical milling of (Bi2O3)(95)(Ta2O5)(5) or (Bi2O3)(80)(Ta2O5)(20) powder mixtures. Compared to its pristine Bi2O3 counterpart with a radiopacity of 4.42 mmAl, long setting times (60 and 120 min for initial and final setting times) and 84% MG-63 cell viability, MTA-like cement prepared from (Bi2O3)(95)(Ta2O5)(5) powder exhibited superior performance with a radiopacity of 5.92 mmAl (the highest in the present work), accelerated setting times (the initial and final setting time can be shortened to 25 and 40 min, respectively), and biocompatibility (94% cell viability).
引用
收藏
页数:12
相关论文
共 30 条
  • [1] Investigation of the toxicity of bismuth oxide nanoparticles in various cell lines
    Abudayyak, Mahmoud
    Oztas, Ezgi
    Arici, Merve
    Ozhan, Gul
    [J]. CHEMOSPHERE, 2017, 169 : 117 - 123
  • [2] Oxidative stress mediated cytotoxicity and apoptosis response of bismuth oxide (Bi2O3) nanoparticles in human breast cancer (MCF-7) cells
    Ahamed, Maqusood
    Akhtar, Mohd Javed
    Khan, M. A. Majeed
    Alrokayan, Salman A.
    Alhadlaq, Hisham A.
    [J]. CHEMOSPHERE, 2019, 216 : 823 - 831
  • [3] Influence of the addition of different radiopacifiers and bioactive nano-hydroxyapatite on physicochemical and biological properties of calcium silicate based endodontic ceramic
    Antonijevic, Djordje
    Despotovic, Ana
    Biocanin, Vladimir
    Milosevic, Milos
    Trisic, Dijana
    Lazovic, Vladimir
    Zogovic, Nevena
    Milasin, Jelena
    Ilic, Dragan
    [J]. CERAMICS INTERNATIONAL, 2021, 47 (20) : 28913 - 28923
  • [4] In vitro biocompatibility of a dentine substitute cement on human MG63 osteoblasts cells: Biodentine™ versus MTA®
    Attik, G. N.
    Villat, C.
    Hallay, F.
    Pradelle-Plasse, N.
    Bonnet, H.
    Moreau, K.
    Colon, P.
    Grosgogeat, B.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2014, 47 (12) : 1133 - 1141
  • [5] POLYMORPHY OF BISMUTH TRIOXIDE
    AURIVILLIUS, B
    SILLEN, LG
    [J]. NATURE, 1945, 155 (3932) : 305 - 306
  • [6] A Short Review on Biomedical Applications of Nanostructured Bismuth Oxide and Related Nanomaterials
    Bartoli, Mattia
    Jagdale, Pravin
    Tagliaferro, Alberto
    [J]. MATERIALS, 2020, 13 (22) : 1 - 17
  • [7] BENJAMIN JS, 1970, METALL TRANS, V1, P2943
  • [8] MECHANICAL ALLOYING
    BENJAMIN, JS
    [J]. SCIENTIFIC AMERICAN, 1976, 234 (05) : 40 - 49
  • [9] Study of fluorite phases in the system Bi2O3-Nb2O5-Ta2O5.: Synthesis by mechanochemical activation assisted methods
    Castro, A
    Palem, D
    [J]. JOURNAL OF MATERIALS CHEMISTRY, 2002, 12 (09) : 2774 - 2780
  • [10] Radiopacity and Cytotoxicity of Portland Cement Containing Zirconia Doped Bismuth Oxide Radiopacifiers
    Chen, Chiehfeng
    Hsieh, Sung-Chih
    Teng, Nai-Chia
    Kao, Chih-Kuo
    Lee, Sheng-Yang
    Lin, Chung-Kwei
    Yang, Jen-Chang
    [J]. JOURNAL OF ENDODONTICS, 2014, 40 (02) : 251 - 254