Coincidence, time alignment of high resolution planar detectors

被引:0
|
作者
Lenox, MW [1 ]
Burbar, Z [1 ]
Young, J [1 ]
Gremillion, T [1 ]
Knoess, C [1 ]
机构
[1] CPS Innnovat, Knoxville, TN USA
关键词
PET; HRRT;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Planar Quadrant Shared Array PET detectors are highly dependent upon accurate timing to improve their coincidence efficiency. Techniques are described to determine the timing characteristics of the planar detectors used in the CPS HRRT PET tomograph, and to compensate for manufacturing tolerances.
引用
收藏
页码:956 / 959
页数:4
相关论文
共 50 条
  • [1] TIME RESOLUTION OF PLANAR GE(LI) DETECTORS IN GAMMA-GAMMA COINCIDENCE EXPERIMENTS
    BALLAND, JC
    PIGNERET, J
    SAMUELI, JJ
    SARAZIN, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1968, NS15 (01) : 411 - +
  • [2] Digital Time Alignment of High Resolution PET Inveon Block Detectors
    Lenox, M. W.
    Atkins, B. E.
    Pressley, D. R.
    McFarland, A.
    Newport, D. F.
    Siegel, S. B.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2450 - 2453
  • [3] Energy and coincidence time resolution measurements of CdTe detectors for PET
    Arino, G.
    Chmeissani, M.
    De Lorenzo, G.
    Puigdengoles, C.
    Cabruja, E.
    Calderon, Y.
    Kolstein, M.
    Macias-Montero, J. G.
    Martinez, R.
    Mikhaylova, E.
    Uzun, D.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [4] Design considerations for PET detectors with 100 picoseconds coincidence time resolution
    Gonzalez-Montoro, A.
    Pourashraf, S.
    Lee, M. S.
    Cates, J. W.
    Levin, C. S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1045
  • [5] Coincidence time alignment for planar pixellated positron emission tomography detector arrays
    Lenox, MW
    Gremillion, T
    Miller, S
    Young, JW
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1952 - 1954
  • [6] Coincidence time resolution measurements for dual-ended readout PET detectors
    Sun, M. D.
    Zhang, C. H.
    Zhao, B. Q.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (07)
  • [7] Approximations of coincidence time resolution models of scintillator detectors with leading edge discriminator
    Vinogradov, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 912 : 149 - 153
  • [8] Determination of the time resolution for neutron scintillation detectors by multi-coincidence measurement
    李永明
    阮锡超
    周斌
    马中原
    中国物理C, 2011, (05) : 475 - 477
  • [9] Determination of the time resolution for neutron scintillation detectors by multi-coincidence measurement
    Li Yong-Ming
    Ruan Xi-Chao
    Zhou Bin
    Ma Zhong-Yuan
    CHINESE PHYSICS C, 2011, 35 (05) : 475 - 477
  • [10] SILICON PLANAR ION DETECTORS WITH HIGH-ENERGY RESOLUTION
    VERBITSKAYA, EM
    EREMIN, VK
    MALYARENKO, AM
    STROKAN, NB
    SUKHANOV, VL
    BORANI, I
    SCHMIDT, B
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1991, 34 (03) : 534 - 539