Challenge for Perceval: Aortic Valve Replacement With Small Sutureless Valves-A Multicenter Study

被引:28
作者
Villa, Emmanuel [1 ]
Messina, Antonio
Laborde, Francois
Shrestha, Malakh
Troise, Giovanni
Zannis, Konstantinos
Haverich, Axel
Elfarra, Mazen
Folliguet, Thierry
机构
[1] Poliambulanza Fdn, Cardiac Surg Unit, IT-25124 Brescia, Italy
关键词
PROSTHESIS-PATIENT MISMATCH; IMPLANTATION; STENOSIS; IMPACT; ROOT; MORTALITY; OUTCOMES; SURGERY; SYSTEM;
D O I
10.1016/j.athoracsur.2014.09.090
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. There is controversy concerning the performance of small aortic prostheses (size < 21). These have been associated with morbidity and mortality after aortic valve replacement (AVR) due to their increased gradient. Sutureless technology is now available but the performance of the smallest of these prostheses needs to be assessed. Methods. The registries of 4 European centers, including 276 consecutive patients (mean age 79.7 +/- 5.2 years, 69.9% females), were reviewed in order to compare data on the smallest model of the Sorin-Perceval sutureless prosthesis (Sorin Group, Saluggia, Italy) compared with larger models. The small valve ("S" size) was inserted (S group) in 47 patients, while 229 patients had a larger one (labeled "M" and "L" by manufacturer, herein L group). Except for body surface area (1.60 +/- 0.16 vs 1.78 +/- 0.19m(2), p < 0.001), there were no other relevant preoperative differences. The European system for cardiac operative risk evaluation log was 11.4 +/- 6.1 versus 12.6 +/- 9.6 (p = 0.28). Results. Median sternotomy was the most frequent approach (S group 87.2% vs L group 79.5%, p = 0.31). The associated procedures were similar for both groups (31.9% vs 34.5%, p = 0.87). For isolated AVR, cardiopulmonary bypass and cross-clamp times were, respectively, 49.1 +/- 16.0 and 30.7 +/- 9.2 minutes (S group) versus 52.6 +/- 23.1 and 32.3 +/- 13.6 minutes (L group) (p = 0.33 and 0.45). Hospital mortality was nil (S group) versus 2.6% (L group) (p = 0.62). At discharge, the peak-pressure-gradients were 22.7 +/- 7.9 and 20.9 +/- 8.4 mm Hg (p = 0.24) while indexed effective orifice areas were 0.84 +/- 0.16 and 0.86 +/- 0.25 cm(2)/m(2) (p [ 0.76). At follow-up (1.5 +/- 1.3 years), echo data and survival did not differ (p = 0.17). Conclusions. This multicenter study confirms the safety, efficacy, and ease of insertion of Perceval valves in elderly patients with small annulus. The performance of the smaller prosthesis was satisfying and prosthesis size did not affect patient outcome. (C) 2015 by The Society of Thoracic Surgeons
引用
收藏
页码:1248 / 1254
页数:7
相关论文
共 22 条
[1]   Cross-clamp time is an independent predictor of mortality and morbidity in low- and high-risk cardiac patients [J].
Al-Sarraf, Nael ;
Thalib, Lukman ;
Hughes, Anne ;
Houlihan, Maighread ;
Tolan, Michael ;
Young, Vincent ;
McGovern, Eillish .
INTERNATIONAL JOURNAL OF SURGERY, 2011, 9 (01) :104-109
[2]   Isolated aortic valve replacement in North America comprising 108,687 patients in 10 years: Changes in risks, valve types, and outcomes in the Society of Thoracic Surgeons National Database [J].
Brown, James M. ;
O'Brien, Sean M. ;
Wu, Changfu ;
Sikora, Jo Ann H. ;
Griffith, Bartley P. ;
Gammie, James S. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (01) :82-90
[3]   Sutureless aortic valve replacement as an alternative treatment for patients belonging to the "gray zone" between transcatheter aortic valve implantation and conventional surgery: A propensity-matched, multicenter analysis [J].
D'Onofrio, Augusto ;
Messina, Antonio ;
Lorusso, Roberto ;
Alfieri, Ottavio R. ;
Fusari, Melissa ;
Rubino, Paolo ;
Rinaldi, Mauro ;
Di Bartolomeo, Roberto ;
Glauber, Mattia ;
Troise, Giovanni ;
Gerosa, Gino .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 144 (05) :1010-1018
[4]   Aortic valve replacement: Results and predictors of mortality from a contemporary series of 2256 patients [J].
Di Eusanio, Marco ;
Fortuna, Daniela ;
De Palma, Rossana ;
Dell'Amore, Andrea ;
Lamarra, Mauro ;
Contini, Giovanni A. ;
Gherli, Tiziano ;
Gabbieri, Davide ;
Ghidoni, Italo ;
Cristell, Donald ;
Zussa, Claudio ;
Pigini, Florio ;
Pugliese, Peppino ;
Pacini, Davide ;
Di Bartolomeo, Roberto .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 141 (04) :940-947
[5]   The bioprosthesis type and size influence the postoperative incidence of permanent pacemaker implantation in patients undergoing aortic valve surgery [J].
Elahi, Maqsood ;
Usmaan, Khalid .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2006, 15 (02) :113-118
[6]   Hemodynamic performance and outcome of percutaneous versus surgical stentless bioprostheses for aortic stenosis with anticipated patient-prosthesis mismatch [J].
Finkelstein, Arie ;
Schwartz, Arie Lorin ;
Uretzky, Gideon ;
Banai, Shmuel ;
Keren, Gad ;
Kramer, Amir ;
Topilsky, Yan .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 147 (06) :1892-1899
[7]   Sutureless Perceval Aortic Valve Replacement: Results of Two European Centers [J].
Folliguet, Thierry A. ;
Laborde, Francois ;
Zannis, Konstantinos ;
Ghorayeb, Gabriel ;
Haverich, Axel ;
Shrestha, Malakh .
ANNALS OF THORACIC SURGERY, 2012, 93 (05) :1483-1488
[8]  
Kato Y, 2013, J HEART VALVE DIS, V22, P468
[9]   One-year outcomes of the Surgical Treatment of Aortic Stenosis With a Next Generation Surgical Aortic Valve (TRITON) trial: A prospective multicenter study of rapid-deployment aortic valve replacement with the EDWARDS INTUITY Valve System [J].
Kocher, Alfred A. ;
Laufer, Guenther ;
Haverich, Axel ;
Shrestha, Malakh ;
Walther, Thomas ;
Misfeld, Martin ;
Kempfert, Joerg ;
Gillam, Linda ;
Schmitz, Christoph ;
Wahlers, Thorsten C. ;
Wippermann, Jens ;
Mohr, Friedrich W. ;
Roth, Matthias ;
Skwara, Adalbert ;
Rahmanian, Parwis ;
Wiedemann, Dominik ;
Borger, Michael A. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 145 (01) :110-116
[10]   25-YEAR REVIEW OF THE MAGOVERN-CROMIE SUTURELESS AORTIC-VALVE [J].
MAGOVERN, GJ ;
LIEBLER, GA ;
PARK, SB ;
BURKHOLDER, JA ;
SAKERT, T ;
SIMPSON, KA .
ANNALS OF THORACIC SURGERY, 1989, 48 (03) :S33-S34