Comparative study between anion-exchange HPLC and homogeneous assay methods in regard to the accuracy of high- and low-density lipoprotein cholesterol measurement

被引:8
作者
Kurosawa, Hideo
Yoshida, Hiroshi
Yanai, Hidekatsu
Ogura, Yutaka
Hirowatari, Yuji
Tada, Norio
机构
[1] Jikei Univ, Dept Lab Med, Chiba 2778567, Japan
[2] Jikei Univ, Kashiwa Hosp, Dept Internal Med, Div Gen Med, Tokyo, Japan
[3] Jikei Univ, Kashiwa Hosp, Dept Lab Med, Tokyo, Japan
关键词
lipoprotein; VLDL; LDL; HDL; HPLC; homogenous assay; cholestasis;
D O I
10.1016/j.clinbiochem.2007.07.008
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: A convenient method based on anion-exchange HPLC was recently developed to determine cholesterol levels of lipoproteins (HDL, LDL, IDL, VLDL, and chylomicron). The present study was performed to compare this HPLC method to homogenous assay in regard to measurement accuracy of HDL and LDL cholesterol. Design and methods: Serum samples (n = 105), including three samples from cholestasis patients, were measured by homogenous assay with Cholestest-LDL and CholestestN-HDL (Daiichi Chemicals, Tokyo) and by HPLC as reported previously (J Lipid Res 2003; 44: 1404-12). Results: The homogenous assay for HDL cholesterol correlated strongly with the HPLC method for HDL cholesterol (r=0.976). Two samples from cholestasis patients could not be measured by homogenous assay but were measured by HPLC. The homogenous assay for LDL cholesterol correlated modestly with the HPLC method for LDL cholesterol (r=0.823). Three outlier samples, from cholestasis patients with serum cholesterol levels > 17 mmol/L, were observed in this correlation analysis. Homogenous assay data showed that these LDL cholesterol levels were 15.2-34.7 mmol/L. However, HPLC data showed that these LDL cholesterol levels were 3.6-8.2 mmol/L, and that the major lipoprotein fractions were VLDL and IDL. The difference in LDL cholesterol levels (homogenous assay data minus HPLC data) was positively correlated with VLDL cholesterol levels. Conclusions: When measuring samples from cholestasis patients, homogenous assay may give inaccurate results. In contrast, the HPLC method is likely to be capable of accurately measuring HDL and LDL cholesterol levels without the involving VLDL. (C) 2007 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1291 / 1296
页数:6
相关论文
共 18 条
[1]   LECITHIN-CHOLESTEROL ACYLTRANSFERASE AND LIPOPROTEIN ABNORMALITIES OF OBSTRUCTIVE-JAUNDICE [J].
AGORASTOS, J ;
FOX, C ;
HARRY, DS ;
MCINTYRE, N .
CLINICAL SCIENCE AND MOLECULAR MEDICINE, 1978, 54 (04) :369-+
[2]  
Arranz-Peña ML, 1998, CLIN CHEM, V44, P2499
[3]   Executive summary of the Third Report of the National Cholesterol Education Program (NCEP) expert panel on detection, evaluation, and treatment of high blood cholesterol in adults (Adult Treatment Panel III) [J].
Cleeman, JI ;
Grundy, SM ;
Becker, D ;
Clark, LT ;
Cooper, RS ;
Denke, MA ;
Howard, WJ ;
Hunninghake, DB ;
Illingworth, DR ;
Luepker, RV ;
McBride, P ;
McKenney, JM ;
Pasternak, RC ;
Stone, NJ ;
Van Horn, L ;
Brewer, HB ;
Ernst, ND ;
Gordon, D ;
Levy, D ;
Rifkind, B ;
Rossouw, JE ;
Savage, P ;
Haffner, SM ;
Orloff, DG ;
Proschan, MA ;
Schwartz, JS ;
Sempos, CT ;
Shero, ST ;
Murray, EZ .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2001, 285 (19) :2486-2497
[4]  
CLIFTON PM, 1988, J LIPID RES, V29, P121
[5]  
Esteban-Salán M, 2000, CLIN CHEM, V46, P1121
[6]  
FRIEDEWALD WT, 1972, CLIN CHEM, V18, P499
[7]   DISTRIBUTION AND CHEMICAL COMPOSITION OF ULTRACENTRIFUGALLY SEPARATED LIPOPROTEINS IN HUMAN SERUM [J].
HAVEL, RJ ;
EDER, HA ;
BRAGDON, JH .
JOURNAL OF CLINICAL INVESTIGATION, 1955, 34 (09) :1345-1353
[8]   Measurement of cholesterol of major serum lipoprotein classes by anion-exchange HPLC with perchlorate ion-containing eluent [J].
Hirowatari, Y ;
Yoshida, H ;
Kurosawa, H ;
Doumitu, K ;
Tada, N .
JOURNAL OF LIPID RESEARCH, 2003, 44 (07) :1404-1412
[9]  
Huang YC, 1997, CLIN CHEM, V43, P1048
[10]  
NAGASAKI T, 1977, CLIN CHIM ACTA, V75, P371