Experimental study on backlayering length of thermal smoke flow in a longitudinally ventilated tunnel with blockage at upstream of fire source

被引:32
作者
Meng, Na [1 ,2 ]
Yang, Wenyu [1 ]
Xin, Lin [1 ]
Li, Xiao [1 ]
Liu, Beibei [1 ]
Jin, Xiaona [1 ]
机构
[1] Shandong Univ Sci & Technol, Coll Min & Safety Engn, Qingdao 266590, Shandong, Peoples R China
[2] Shandong Univ Sci & Technol, Natl Demonstrat Ctr Expt Min Engn Educ, Qingdao 266590, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
Tunnel fire; Longitudinal ventilation; Backlayering length; Blockage ratio; Blockage-fire distance; BACK-LAYERING LENGTH; CRITICAL VELOCITY; CEILING EXTRACTION; MAXIMUM TEMPERATURE; VERTICAL SHAFTS; CROSS-SECTION; METRO TUNNEL; ROAD TUNNEL; HEAT-SOURCE; BUOYANCY;
D O I
10.1016/j.tust.2018.08.034
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Experiments were conducted in a model tunnel to investigate backlayering length of thermal smoke flow in a longitudinally ventilated tunnel with vehicular blockage at upstream of the fire source. Two kinds of blockage ratios were considered and the horizontal distance between the fire and the blockage is in the range of 1-5 m. It is found that with no blockage, the experimental data can be well collapsed by Li model (without blockage). With blockage, the backlayering length is found to be lower than that in an empty tunnel. Both Tang model and Li model (with blockage) fail to predict the backlayering length in our present work. The backlayering length decreases or increases with increasing blockage-fire distance at blockage ratio of 0.26 and given heat release rates, however, at blockage ratio of 0.51 and given heat release rate, the backlayering length increases with increasing blockage-fire distance at large ventilation velocity. At certain heat release rate and ventilation velocity, the backlayering length is larger for cases with smaller blockage ratio, and this discrepancy gradually decreases with increasing blockage-fire distance at larger ventilation velocity, and finally longer backlayering length can be obtained for cases with larger blockage ratio. Larger backlayering length could be obtained for cases with higher heat release rates irrespective of the blockage-fire distance at blockage ratio of 0.26 and given ventilation velocities.
引用
收藏
页码:315 / 324
页数:10
相关论文
共 50 条
[31]   Full-scale immersed tunnel fire experimental research on smoke flow patterns [J].
Xu, P. ;
Jiang, S. P. ;
Xing, R. J. ;
Tan, J. Q. .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2018, 81 :494-505
[32]   Effect of ceiling centralized mechanical smoke exhaust on the critical velocity that inhibits the reverse flow of thermal plume in a longitudinal ventilated tunnel [J].
Tang, Fei ;
He, Qing ;
Mei, Fengzhu ;
Wang, Qiang ;
Zhang, Heng .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2018, 82 :191-198
[33]   Thermal buoyant smoke back-layering flow length in a longitudinal ventilated tunnel with ceiling extraction at difference distance from heat source [J].
Chen, L. F. ;
Hu, L. H. ;
Zhang, X. L. ;
Zhang, X. Z. ;
Zhang, X. C. ;
Yang, L. Z. .
APPLIED THERMAL ENGINEERING, 2015, 78 :129-135
[34]   Experimental study on the effect of lateral concentrated smoke extraction on smoke stratification in the longitudinal ventilated tunnel [J].
Tang, Fei ;
Zhu, Yuantao ;
Chen, Lei .
FIRE AND MATERIALS, 2020, 44 (07) :1004-1012
[35]   Analysis of experimental data on the effect of fire source elevation on fire and smoke dynamics and the critical velocity in a tunnel with longitudinal ventilation [J].
Liu, Yuanjun ;
Fang, Zheng ;
Tang, Zhi ;
Beji, Tarek ;
Merci, Bart .
FIRE SAFETY JOURNAL, 2020, 114
[36]   Experimental study on transverse fire source and blockage locations influence on tunnel fire temperature distribution [J].
Li, Linjie ;
Wang, Zhen ;
Wu, Zhaoguo ;
Huang, Huixian ;
Zhang, Haibing ;
Gao, Zihe .
CASE STUDIES IN THERMAL ENGINEERING, 2024, 61
[37]   Experimental Study on the Influence of Fire Source Elevation on Smoke Temperature Profile Driven by Buoyancy in a Full-scale Mountain Tunnel [J].
Li, Zhisheng ;
Zhang, Yuchun ;
Guo, Hanwen ;
Lin, Youxin ;
Cheng, Yanying ;
Gao, Yunji ;
Chen, Longfei ;
Li, Xiaosong ;
Xing, Shaoshuai ;
Li, Tao .
COMBUSTION SCIENCE AND TECHNOLOGY, 2023, 195 (06) :1151-1168
[38]   Critical velocity for preventing thermal backlayering flow in tunnel fire using longitudinal ventilation system: Effect of floor-fire separation distance [J].
Gannouni, Soufien .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2022, 171
[39]   Experimental study on smoke characteristics of bifurcated tunnel fire [J].
Chen, Longfei ;
Mao, Pengfei ;
Zhang, Yuchun ;
Xing, Shaoshuai ;
Li, Tao .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2020, 98
[40]   Effect of blockage-heat source distance on maximum temperature of buoyancy-induced smoke flow beneath ceiling in a longitudinal ventilated tunnel [J].
Tang, F. ;
Cao, Z. L. ;
Chen, Q. ;
Meng, N. ;
Wang, Q. ;
Fan, C. G. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 109 :683-688