Experimental study on backlayering length of thermal smoke flow in a longitudinally ventilated tunnel with blockage at upstream of fire source

被引:31
作者
Meng, Na [1 ,2 ]
Yang, Wenyu [1 ]
Xin, Lin [1 ]
Li, Xiao [1 ]
Liu, Beibei [1 ]
Jin, Xiaona [1 ]
机构
[1] Shandong Univ Sci & Technol, Coll Min & Safety Engn, Qingdao 266590, Shandong, Peoples R China
[2] Shandong Univ Sci & Technol, Natl Demonstrat Ctr Expt Min Engn Educ, Qingdao 266590, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
Tunnel fire; Longitudinal ventilation; Backlayering length; Blockage ratio; Blockage-fire distance; BACK-LAYERING LENGTH; CRITICAL VELOCITY; CEILING EXTRACTION; MAXIMUM TEMPERATURE; VERTICAL SHAFTS; CROSS-SECTION; METRO TUNNEL; ROAD TUNNEL; HEAT-SOURCE; BUOYANCY;
D O I
10.1016/j.tust.2018.08.034
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Experiments were conducted in a model tunnel to investigate backlayering length of thermal smoke flow in a longitudinally ventilated tunnel with vehicular blockage at upstream of the fire source. Two kinds of blockage ratios were considered and the horizontal distance between the fire and the blockage is in the range of 1-5 m. It is found that with no blockage, the experimental data can be well collapsed by Li model (without blockage). With blockage, the backlayering length is found to be lower than that in an empty tunnel. Both Tang model and Li model (with blockage) fail to predict the backlayering length in our present work. The backlayering length decreases or increases with increasing blockage-fire distance at blockage ratio of 0.26 and given heat release rates, however, at blockage ratio of 0.51 and given heat release rate, the backlayering length increases with increasing blockage-fire distance at large ventilation velocity. At certain heat release rate and ventilation velocity, the backlayering length is larger for cases with smaller blockage ratio, and this discrepancy gradually decreases with increasing blockage-fire distance at larger ventilation velocity, and finally longer backlayering length can be obtained for cases with larger blockage ratio. Larger backlayering length could be obtained for cases with higher heat release rates irrespective of the blockage-fire distance at blockage ratio of 0.26 and given ventilation velocities.
引用
收藏
页码:315 / 324
页数:10
相关论文
共 50 条
[21]   An experimental study on the transition velocity and smoke back-layering length induced by carriage fire in a ventilated tunnel [J].
Hu, Peng ;
Zhang, Zhenyi ;
Zhang, Xiaochun ;
Tang, Fei .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2020, 106
[22]   A numerical study on critical velocity and back-layering length with trains' blockage in longitudinally ventilated tunnel fires [J].
Zhang, Xiaochun ;
Zhang, Zhenyi ;
Tao, Haowen .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2021, 116
[23]   Evaluating the smoke back-layering length and critical velocity in branched tunnel fire with sloped mainline: An experimental study [J].
Huang, Youbo ;
Luo, Chengjia ;
Liu, Xi ;
Tang, Fei ;
Dong, Bingyan ;
Zhong, Hua .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2024, 143
[24]   Thermal buoyant smoke back-layering length in a naturally ventilated tunnel with vertical shafts [J].
Wang, Yan Fu ;
Yan, Pei Na ;
Zhang, Biao ;
Jiang, Jun Cheng .
APPLIED THERMAL ENGINEERING, 2016, 93 :947-957
[25]   Numerical and experimental study on the effects of a ceiling beam on the critical velocity of a tunnel fire based on virtual fire source [J].
Tian, Xiangliang ;
Liu, Chang ;
Zhong, Maohua .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2021, 159
[26]   Effect of blockage-fire distance on buoyancy driven back-layering length and critical velocity in a tunnel: An experimental investigation and global correlations [J].
Tang, W. ;
Hu, L. H. ;
Chen, L. F. .
APPLIED THERMAL ENGINEERING, 2013, 60 (1-2) :7-14
[27]   Effect of vehicular blockage on critical ventilation velocity and tunnel fire behavior in longitudinally ventilated tunnels [J].
Lee, Yee-Ping ;
Tsai, Kuang-Chung .
FIRE SAFETY JOURNAL, 2012, 53 :35-42
[28]   Modelling and experimental investigation of critical velocity and driving force for preventing smoke backlayering in a branched tunnel fire [J].
Huang, Youbo ;
Li, Yanfeng ;
Li, Junmei ;
Li, Jiaxin ;
Wu, Ke ;
Zhu, Kai ;
Li, Haihang .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2020, 99
[29]   Effects of fire-blockage distance on pool fire burning behavior and thermal temperature profiles in a naturally ventilated tunnel [J].
Han, Jiaqiang ;
Geng, Pengqiang ;
Wang, Zihao ;
Wang, Fei ;
Weng, Miaocheng ;
Liu, Fang .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2021, 117
[30]   Maximum smoke temperature in the longitudinally ventilated tunnel fire: Influence of the separating distance between two sources [J].
Ma, Xin ;
Luo, Shengfeng ;
Fang, Tingyong ;
Wang, Jingwei ;
Wan, Lulu .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2021, 107