Remote Magnetic Navigation With Irrigated Tip Catheter for Ablation of Paroxysmal Atrial Fibrillation

被引:62
作者
Miyazaki, Shinsuke [1 ,2 ]
Shah, Ashok J. [1 ,2 ]
Xhaet, Olivier [1 ,2 ]
Derval, Nicolas [1 ,2 ]
Matsuo, Seiichiro [1 ,2 ]
Wright, Matthew [1 ,2 ,3 ]
Nault, Isabelle [1 ,2 ]
Forclaz, Andrei [1 ,2 ]
Jadidi, Amir S. [1 ,2 ]
Knecht, Sebastien [1 ,2 ]
Rivard, Lena [1 ,2 ]
Liu, Xingpeng [1 ,2 ]
Linton, Nick [1 ,2 ]
Sacher, Frederic [1 ,2 ]
Hocini, Meleze [1 ,2 ]
Jais, Pierre [1 ,2 ]
Haissaguerre, Michel [1 ,2 ]
机构
[1] Hop Cardiol Haut Leveque, Bordeaux, France
[2] Univ Bordeaux 2, F-33076 Bordeaux, France
[3] Guys & St Thomas NHS Fdn Trust, NIHR Biomed Res Ctr, Div Cardiovasc, Kings Coll London BHF Ctr, London, England
关键词
atrial fibrillation; catheter ablation; robotics; irrigation; INITIAL-EXPERIENCE; GUIDANCE-SYSTEM; TRIAL;
D O I
10.1161/CIRCEP.110.957803
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The remote magnetic navigation system (MNS) has been used with a nonirrigated magnetic catheter for atrial fibrillation (AF) ablation. The objective of this study was to evaluate the feasibility and efficiency of the newly available irrigated tip magnetic catheter for index pulmonary vein isolation (PVI) in patients with paroxysmal AF (PAF). Methods and Results-Between January 2008 and June 2009, 30 consecutive patients with drug-resistant PAF underwent circular mapping catheter-guided PVI with MNS (MNS group). The outcomes were compared retrospectively with those of a conventional hand-controlled ablation technique during the same period in 44 consecutive patients (manual group). All 4 pulmonary veins were successfully isolated in both groups except in 4 patients in the MNS group. Radiofrequency and procedure duration were higher in the MNS group (60 +/- 27 versus 43 +/- 16 minutes; P=0.0019) than in the manual group (246 +/- 50 versus 153 +/- 51 minutes; P < 0.0001). In the patients who underwent only PVI, total fluoroscopic time also was longer in the MNS group than in the manual group (58 +/- 24 versus 40 +/- 14 minutes; P=0.0002). At 12-month follow-up after a single procedure, 69.0% of the patients in MNS group and 61.8% of patients in manual group were free of atrial tachyarrhythmia without antiarrhythmic drugs. There was no significant difference in the atrial tachyarrhythmia-free survival between the 2 groups (P=0.961). Cardiac tamponade occurred in 1 patient in the manual group. Conclusions-In patients with PAF, MNS-guided PVI with the newly available irrigated tip magnetic catheter backed up with manual ablation whenever required is feasible. However, it requires longer ablation, fluoroscopy, and procedural times than the conventional approach in the early experience stage. (Circ Arrhythm Electrophysiol. 2010;3:585-589.)
引用
收藏
页码:585 / 589
页数:5
相关论文
共 13 条
[1]   Initial clinical experience with a remote magnetic catheter navigation system for ablation of cavotricuspid isthmus-dependent right atrial flutter [J].
Arya, Arash ;
Kottkamp, Hans ;
Piorkowski, Christopher ;
Bollmann, Andreas ;
Gerdes-Li, Jin-Hong ;
Riahi, Sam ;
Esato, Masahiro ;
Hindricks, Gerhard .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 (05) :597-603
[2]   HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: Recommendations for personnel, policy, procedures and follow-up [J].
Calkins, Hugh ;
Brugada, Josep ;
Packer, Douglas L. ;
Cappato, Riccardo ;
Chen, Shih-Ann ;
Crijns, Harry J. G. ;
Damiano, Ralph J., Jr. ;
Davies, D. Wyn ;
Haines, David E. ;
Haissaguerre, Michel ;
Iesaka, Yoshito ;
Jackman, Warren ;
Jais, Pierre ;
Kottkamp, Hans ;
Kuck, Karl Heinz ;
Lindsay, Bruce D. ;
Marchlinski, Francis E. ;
McCarthy, Patrick M. ;
Mont, J. Lluis ;
Morady, Fred ;
Nademanee, Koontawee ;
Natale, Andrea ;
Pappone, Carlo ;
Prystowsky, Eric ;
Raviele, Antonio ;
Ruskin, Jeremy N. ;
Shemin, Richard J. .
HEART RHYTHM, 2007, 4 (06) :816-861
[3]   Remote magnetic navigation - Human experience in pulmonary vein ablation [J].
Di Blase, Luigi ;
Fahmy, Tamer S. ;
Patel, Dimpi ;
Bai, Rong ;
Civello, Kenneth ;
Wazni, Oussama M. ;
Kanj, Mohamed ;
Elayi, Claude S. ;
Ching, Chi Keong ;
Khan, Mohamed ;
Popova, Lucie ;
Schweikert, Robert A. ;
Cummings, Jennifer E. ;
Burkhardt, J. David ;
Martin, David O. ;
Bhargava, Mandeep ;
Dresing, Thomas ;
Saliba, Walid ;
Arruda, Mauricio ;
Natale, Andrea .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (09) :868-874
[4]   Evaluation of a radiation protection cabin for invasive electrophysiological procedures [J].
Dragusin, Octavian ;
Weerasooriya, Rukshen ;
Jais, Pierre ;
Hocini, Meleze ;
Ector, Joris ;
Takahashi, Yoshihide ;
Haissaguerre, Michel ;
Bosmans, Hilde ;
Heidbuchel, Hein .
EUROPEAN HEART JOURNAL, 2007, 28 (02) :183-189
[5]   Initial experience with remote catheter ablation using a novel magnetic navigation system -: Magnetic remote catheter ablation [J].
Ernst, S ;
Ouyang, FF ;
Linder, C ;
Hertting, K ;
Stahl, F ;
Chun, J ;
Hachiya, H ;
Bänsch, D ;
Antz, M ;
Kuck, KH .
CIRCULATION, 2004, 109 (12) :1472-1475
[6]   Magnetic guidance system for cardiac electrophysiology - A prospective trial of safety and efficacy in humans [J].
Faddis, MN ;
Chen, J ;
Osborn, J ;
Talcott, M ;
Cain, ME ;
Lindsay, BD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (11) :1952-1958
[7]  
Haïssaguerre M, 2000, CIRCULATION, V102, pE123
[8]   Radiofrequency ablation of atrioventricular nodal reentrant tachycardia using a novel magnetic guidance system compared with a conventional approach [J].
Kerzner, R ;
Sánchez, JM ;
Osborn, JL ;
Chen, J ;
Faddis, MN ;
Gleva, MJ ;
Lindsay, BD ;
Smith, TW .
HEART RHYTHM, 2006, 3 (03) :261-267
[9]   Atrial Fibrillation Ablation by Aortic Retrograde Approach Using a Magnetic Navigation System [J].
Miyazaki, Shinsuke ;
Nault, Isabelle ;
Haissaguerre, Michel ;
Hocini, Meleze .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2010, 21 (04) :455-457
[10]   Initial Experience with Catheter Ablation Using Remote Magnetic Navigation in Adults with Complex Congenital Heart Disease and in Small Children [J].
Schwagten, Bruno ;
Jordaens, Luc ;
Witsenburg, Martin ;
Duplessis, Frederik ;
Thornton, Andrew ;
Van Belle, Yves ;
Szili-Torok, Tamas .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 :S198-S201