Intracochlear Recordings of Acoustically and Electrically Evoked Potentials in Nucleus Hybrid L24 Cochlear Implant Users and Their Relationship to Speech Perception

被引:24
|
作者
Kim, Jae-Ryong [1 ,2 ]
Tejani, Viral D. [1 ,3 ]
Abbas, Paul J. [1 ,3 ]
Brown, Carolyn J. [1 ,3 ]
机构
[1] Univ Iowa, Dept Commun Sci & Disorders, Iowa City, IA 52242 USA
[2] Inje Univ, Coll Med, Dept Otolaryngol Head & Neck Surg, Busan, South Korea
[3] Univ Iowa Hosp & Clin, Dept Otolaryngol Head & Neck Surg, Iowa City, IA 52242 USA
来源
FRONTIERS IN NEUROSCIENCE | 2017年 / 11卷
关键词
cochlear implant; auditory evoked potentials; electrocochleography; electrically evoked compound action potential; hybrid cochlear implant; neural response telemetry; HEARING PRESERVATION OUTCOMES; MULTICENTER CLINICAL-TRIAL; SPIRAL GANGLION-CELLS; SHORT ELECTRODE ARRAY; BRAIN-STEM RESPONSE; NERVE SURVIVAL; FUNDAMENTAL-FREQUENCY; WORD RECOGNITION; TEMPORAL CUES; RECIPIENTS;
D O I
10.3389/fnins.2017.00216
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The Hybrid cochlear implant (CI) has been developed for individuals with high frequency hearing loss who retain good low frequency hearing. Outcomes have been encouraging but individual variability is high; the health of the cochlea and the auditory nerve may be important factors driving outcomes. Electrically evoked compound action potentials (ECAPs) reflect the response of the auditory nerve to electrical stimulation while electrocochleography (ECochG) reflects the response of the cochlear hair cells and auditory nerve to acoustic stimulation. In this study both ECAPs and ECochG responses were recorded from Nucleus Hybrid L24 CI users. Correlations between these two measures of peripheral auditory function and speech perception are reported. This retrospective study includes data from 25 L24 CI users. ECAPs and ECochG responses were recorded from an intracochlear electrode using stimuli presented at or near maximum acceptable loudness levels. Speech perception was assessed using Consonant-Nucleus-Consonant (CNC) word lists presented in quiet and AzBio sentences presented at a +5 dB signal-to-noise ratio in both the combined acoustic and electric (A+E) and electric (E) alone listening modes. Acoustic gain was calculated by subtracting these two scores. Correlations between these physiologic and speech perception measures were then computed. ECAP amplitudes recorded from the most apical electrode were significantly correlated with CNC scores measured in the E alone (r = 0.56) and A+E conditions (r = 0.64), but not with performance on the AzBio test. ECochG responses recorded using the most apical electrode in the intracochlear array but evoked using a 500 Hz tone burst were not correlated with either the scores on the CNC or AzBio tests. However, ECochG amplitude was correlated with a composite metric relating the additional benefit of acoustic gain in noise relative to quiet conditions (r = 0.67). Both measures can be recorded from Hybrid L24 CI users and both ECAP and ECochG measures may result in more complete characterization of speech perception outcomes than either measure alone.
引用
收藏
页数:14
相关论文
共 28 条
  • [21] SpeedCAP: An Efficient Method for Estimating Neural Activation Patterns Using Electrically Evoked Compound Action-Potentials in Cochlear Implant Users
    Garcia, Charlotte
    Deeks, John M.
    Goehring, Tobias
    Borsetto, Daniele
    Bance, Manohar
    Carlyon, Robert P.
    EAR AND HEARING, 2023, 44 (03): : 627 - 640
  • [22] Normative findings of electrically evoked compound action potential measurements uing the neural response telemetry of the nucleus CI24M cochlear implant system
    Dees, DC
    Dillier, N
    Lai, WK
    von Wallenberg, E
    van Dijk, B
    Akdas, F
    Aksit, M
    Batman, C
    Beynon, A
    Burdo, S
    Chanal, JM
    Collet, L
    Conway, M
    Coudert, C
    Craddock, L
    Cullington, H
    Deggouj, N
    Fraysse, B
    Grabel, S
    Kiefer, J
    Kiss, JG
    Lenarz, T
    Mair, A
    Maune, S
    Müller-Deile, J
    Piron, JP
    Razza, S
    Tasche, C
    Thai-Van, H
    Toth, F
    Truy, E
    Uziel, A
    Smoorenburg, GF
    AUDIOLOGY AND NEURO-OTOLOGY, 2005, 10 (02) : 105 - 116
  • [23] Modeling the relationship between psychophysical perception and electrically evoked compound action potential threshold in young cochlear implant recipients: clinical implications for implant fitting
    Thai-Van, H
    Truy, E
    Charasse, B
    Boutitie, F
    Chanal, JM
    Cochard, N
    Piron, JP
    Ribas, S
    Deguine, O
    Fraysse, B
    Mondain, M
    Uziel, A
    Collet, L
    CLINICAL NEUROPHYSIOLOGY, 2004, 115 (12) : 2811 - 2824
  • [24] Comparison of speech recognition with different speech coding strategies (SPEAK, CIS, and ACE) and their relationship to telemetric measures of compound action potentials in the nucleus CI 24M cochlear implant system
    Kiefer, J
    Hohl, S
    Stürzebecher, E
    Pfennigdorff, T
    Gstöettner, W
    AUDIOLOGY, 2001, 40 (01): : 32 - 42
  • [25] Electrically evoked whole nerve action potentials in ineraid cochlear implant users: Responses to different stimulating electrode configurations and comparison to psychophysical responses
    Brown, CJ
    Abbas, PJ
    Borland, J
    Bertschy, MR
    JOURNAL OF SPEECH AND HEARING RESEARCH, 1996, 39 (03): : 453 - 467
  • [26] Comparison of speech perception benefits with SPEAK and ACE coding strategies in pediatric Nucleus CI24M cochlear implant recipients
    Pasanisi, E
    Bacciu, A
    Vincenti, V
    Guida, M
    Berghenti, MT
    Barbot, A
    Panu, F
    Bacciu, S
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2002, 64 (02) : 159 - 163
  • [27] Electrically Evoked Amplitude Modulation Following Response in Cochlear Implant Candidates: Comparison With Auditory Nerve Response Telemetry, Subjective Electrical Stimulation, and Speech Perception
    Hirschfelder, Anke
    Graebel, Stefan
    Olze, Heidi
    OTOLOGY & NEUROTOLOGY, 2012, 33 (06) : 968 - 975
  • [28] Relationship Between the Ability to Detect Frequency Changes or Temporal Gaps and Speech Perception Performance in Post-lingual Cochlear Implant Users
    Xie, Dianzhao
    Luo, Jianfen
    Chao, Xiuhua
    Li, Jinming
    Liu, Xianqi
    Fan, Zhaomin
    Wang, Haibo
    Xu, Lei
    FRONTIERS IN NEUROSCIENCE, 2022, 16