Comprehensive Assessment of Lightning Protection Schemes for 10 kV Overhead Distribution Lines

被引:20
|
作者
Cao, Jinxin [1 ]
Du, Yaping [1 ]
Ding, Yuxuan [1 ]
Qi, Ruihan [2 ]
Li, Binghao [1 ]
Chen, Mingli [1 ]
Li, Zhe [3 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Hung Hom, Hong Kong, Peoples R China
[2] China Southern Power Grid, State Key Lab HVDC Transmiss Technol, Guangzhou 510000, Peoples R China
[3] China Southern Power Grid, Shenzhen Power Supply Bur, Shenzhen 10000, Peoples R China
关键词
Lightning; Wires; Surges; Arresters; Lightning protection; Monte Carlo methods; Flashover; overhead line; Monte Carlo simulation; medium voltage; economic analysis; POWER DISTRIBUTION LINES; INDUCED VOLTAGES; INDUCED OVERVOLTAGES; SHIELD WIRES; PERFORMANCE; ARRESTERS; SYSTEMS;
D O I
10.1109/TPWRD.2021.3110248
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents an assessment of lightning protection schemes for overhead lines from two aspects: protection performance and economic cost. Considering the random nature of lightning, the Monte-Carlo method with a heuristic technique is applied in the assessment. The one-dimensional finite-difference time-domain method is adopted to evaluate lightning overvoltages on insulators and lightning currents in surge arresters for failure assessment. The failure rate of an overhead line is addressed under both direct lightning and indirect lightning. A reduced set of design parameters are identified. It is found that the line insulation itself with a critical flashover overvoltage of less than 200 kV is not sufficient for lightning protection, especially against direct strokes. With other protection options, however, increasing the insulation level can greatly improve the protection performance. Installing surge arresters on every pole results in the best protection performance, but could be extremely expensive due to the replacement of failed surge arresters. The shielding wire provides moderate protection performance with a relatively low cost. The combination of the shielding wire and surge arresters provides much better performance under a wide range of soil conductivity with a moderate cost. It is worth mentioning that adopting high insulation strength for overhead lines in the new-line design could lead to significant cost savings for lightning protection. Guidelines for selecting design parameter values and protection schemes are provided, as well as a procedure for performance-cost evaluation.
引用
收藏
页码:2326 / 2336
页数:11
相关论文
共 50 条
  • [31] Line arresters and underbuilt wire application in lightning protection of 110 kV and 220 kV overhead transmission lines
    Banjanin, Mladen
    2019 18TH INTERNATIONAL SYMPOSIUM INFOTEH-JAHORINA (INFOTEH), 2019,
  • [32] Lightning Protection of A 22kV Distribution Overhead Line- A Case Study
    Khuluse, P. N.
    Nnachi, A. F.
    Moloi, K.
    Akumu, A. O.
    2020 6TH IEEE INTERNATIONAL ENERGY CONFERENCE (ENERGYCON), 2020, : 792 - 796
  • [33] Lightning protection technology based on LPM for ± 1500kV UHVDC overhead transmission lines
    Xia Chao
    Chen Xiujuan
    Lu Tiantian
    Shi Weidong
    Lei Ting
    Ma Xiaoguang
    Zhang Zhaohua
    2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 2458 - 2462
  • [34] LIGHTNING - INDUCED OVERVOLTAGES ON OVERHEAD DISTRIBUTION LINES
    ERIKSSON, AJ
    STRINGFELLOW, MF
    MEAL, DV
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (04): : 960 - 968
  • [35] Lightning Performance Indices of Overhead Distribution Lines
    Klairuang, N.
    Unahalekhaka, P.
    Somkanea, S.
    Soasuwan, A.
    UPEC: 2009 44TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, 2009, : 206 - +
  • [36] Analysis of the Lightning Performance of Overhead Distribution Lines
    Coelho, Vilson Luiz
    Raizer, Adroaldo
    Saldanha Paulino, Jose Osvaldo
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (03) : 1706 - 1712
  • [37] LIGHTNING PROTECTION OF DISTRIBUTION LINES
    MCDERMOTT, TE
    SHORT, TA
    ANDERSON, JG
    IEEE TRANSACTIONS ON POWER DELIVERY, 1994, 9 (01) : 138 - 146
  • [38] Improving the lightning performance of overhead distribution lines
    Thanasaksiri, T
    TENCON 2004 - 2004 IEEE REGION 10 CONFERENCE, VOLS A-D, PROCEEDINGS: ANALOG AND DIGITAL TECHNIQUES IN ELECTRICAL ENGINEERING, 2004, : C369 - C372
  • [39] Grounding of Overhead Transmission Lines for Improved Lightning Protection
    Chisholm, William A.
    Petrache, Emanuel
    Bologna, Fabio
    2010 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION: SMART SOLUTIONS FOR A CHANGING WORLD, 2010,
  • [40] Calculation of Lightning Trip-out Rates for 10 kV Overhead Distribution Line
    Lu Zejun
    Gu Shanqiang
    Zhao Chun
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 667 - 670