QUALITAS:: A mid-infrared spectrometer for sensitive trace gas measurements based on quantum cascade lasers in CW operation -: art. no. 075102

被引:28
作者
Kormann, R [1 ]
Königstedt, R [1 ]
Parchatka, U [1 ]
Lelieveld, J [1 ]
Fischer, H [1 ]
机构
[1] Max Planck Inst Chem, D-55128 Mainz, Germany
关键词
D O I
10.1063/1.1931233
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We describe QUALITAS, a mid-infrared spectrometer with multipass absorption cell, suitable to apply lead chalcogenide and quantum cascade lasers as light sources in CW operation at cryogenic temperatures. The instrument has been designed for the measurement of trace gases such as carbon monoxide, nitrous oxide or methane in the clean atmosphere from space-restricted and experimentally challenging mobile platforms. The design involves compact optics, which fit into the space limitations of a standard aircraft borne 19 in. rack (WxHxD approximate to 48x45x40 cm(3)). The instrument allows high sensitivity (approximate to 5x10(-7) m(-1) Hz(-1/2) during flight; approximate to 1x10(-7) m(-1) Hz(-1/2) in the laboratory) in combination with a low sample gas volume (0.3 L) for high time resolution (< 1 s, using a moderately sized pump). We employ a combination of elements already applied in former spectrometers in our laboratory and a novel arrangement of spherical mirrors. The design criteria, the optical, electronic and mechanical set-up are described in detail. The application of the instrument to measure atmospheric concentrations of carbon monoxide is discussed, using both, a lead chalcogenide as well as a DFB-structured quantum cascade laser (R3 line at 2158.3 cm(-1)). (c) 2005 American Institute of Physics.
引用
收藏
页数:8
相关论文
共 17 条
[1]  
[Anonymous], ADV SPECTROSCOPY
[2]  
DYROFF C, 2003, THESIS EMDEN
[3]  
GENSTY T, 2003, COMMUNICATION
[4]   Application of a multi-laser tunable diode laser absorption spectrometer for atmospheric trace gas measurements at sub-ppbv levels [J].
Kormann, R ;
Fischer, H ;
Gurk, C ;
Helleis, F ;
Klüpfel, T ;
Kowalski, K ;
Königstedt, R ;
Parchatka, U ;
Wagner, V .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2002, 58 (11) :2489-2498
[5]   A compact multi-laser TDLAS for trace gas flux measurements based on a micrometeorological technique [J].
Kormann, R ;
Fischer, H ;
Wienhold, FG .
APPLICATION OF TUNABLE DIODE AND OTHER INFRARED SOURCES FOR ATMOSPHERIC STUDIES AND INDUSTRIAL PROCESSING MONITORING II, 1999, 3758 :162-169
[6]  
MANN C, 2003, QUANTUM CASCADE LASE, V43
[7]   ASTIGMATIC MIRROR MULTIPASS ABSORPTION CELLS FOR LONG-PATH-LENGTH SPECTROSCOPY [J].
MCMANUS, JB ;
KEBABIAN, PL ;
ZAHNISER, WS .
APPLIED OPTICS, 1995, 34 (18) :3336-3348
[8]  
RIDLEY BA, 1992, J ATMOS OCEAN TECH, V9, P142, DOI 10.1175/1520-0426(1992)009<0142:ASHSMR>2.0.CO
[9]  
2
[10]  
RIEDEL WJ, 1991, SPIE INT S LAS SPECT