Multimodal Analog Front End for Wearable Bio-Sensors

被引:24
作者
Kim, Insoo [1 ]
Bhagat, Yusuf A. [1 ]
Homer, Johnny [1 ]
Lobo, Ryan [1 ]
机构
[1] Samsung Res Amer, Richardson, TX 75082 USA
关键词
Analog front-end; bio-sensors; bio-potential; bioimpedance analysis; photoplethysmography; wearable sensors; HEALTH-CARE-SYSTEM; BIOELECTRICAL-IMPEDANCE; DEVICE;
D O I
10.1109/JSEN.2016.2564942
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Wearable sensors afford convenience in daily health monitoring, though many challenges in the development of such systems need to be overcome. Here, we present a low-power, multi-modal analog front end (AFE) for wearable health monitoring sensors based on novel system architecture and very large scale integration circuit design methods. The AFE integrated circuit was designed with the standard 65-nm CMOS technology. Three sensor AFEs, bio-potential, photoplethysmography (PPG), and bioelectrical impedance analyser (BIA) were integrated on the same die with an area of 2.5 x 2.5 mm(2). The power consumption for each AFE mode was <0.4 mW and did not exceed 2 mW for all three modes with a 1.2 V power supply. Results from each individual AFE showed high-quality, motion-robust signals (electrocardiogram, PPG, and BIA) that correlated with those obtained from clinical grade gold-standard devices for similar applications. Such multi-functional, non-intrusive systems permit users to effortlessly self-monitor multiple clinically relevant physiological parameters.
引用
收藏
页码:8784 / 8791
页数:8
相关论文
共 29 条
[1]   From Wearable Sensors to Smart Implants-Toward Pervasive and Personalized Healthcare [J].
Andreu-Perez, Javier ;
Leff, Daniel R. ;
Ip, H. M. D. ;
Yang, Guang-Zhong .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (12) :2750-2762
[2]   Mobile monitoring with wearable photoplethysmographic biosensors [J].
Asada, HH ;
Shaltis, P ;
Reisner, A ;
Rhee, S ;
Hutchinson, RC .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2003, 22 (03) :28-40
[3]   Mind Your Composition Clinical validation of Samsung's pocket-based bioelectrical impedance analyzers may increase consumer interest in personal health management [J].
Bhagat, Yusuf A. ;
Kim, Insoo ;
Choi, Ahyoung ;
Kim, Justin Younghyun ;
Jo, Seongwook ;
Cho, Jaegeol .
IEEE PULSE, 2015, 6 (05) :20-25
[4]   Correlation Between Electrode-Tissue Impedance and Motion Artifact in Biopotential Recordings [J].
Buxi, Dilpreet ;
Kim, Sunyoung ;
van Helleputte, Nick ;
Altini, Marco ;
Wijsman, Jacqueline ;
Yazicioglu, Refet Firat ;
Penders, Julien ;
van Hoof, Chris .
IEEE SENSORS JOURNAL, 2012, 12 (12) :3373-3383
[5]   Smartphone-Based Bioelectrical Impedance Analysis Devices for Daily Obesity Management [J].
Choi, Ahyoung ;
Kim, Justin Younghyun ;
Jo, Seongwook ;
Jee, Jae Hwan ;
Heymsfield, Steven B. ;
Bhagat, Yusuf A. ;
Kim, Insoo ;
Cho, Jaegeol .
SENSORS, 2015, 15 (09) :22151-22166
[6]  
CHUMLEA WC, 1994, NUTR REV, V52, P123, DOI 10.1111/j.1753-4887.1994.tb01404.x
[7]   Open platform, eight-channel, portable bio-potential and activity data logger for wearable medical device development [J].
Cook, A. J. ;
Gargiulo, G. D. ;
Lehmann, T. ;
Hamilton, T. J. .
ELECTRONICS LETTERS, 2015, 51 (21) :1641-1642
[8]  
Ding XR, 2015, IEEE ENG MED BIO, P398, DOI 10.1109/EMBC.2015.7318383
[9]  
Dionisi A., IEEE T INSTRUM UNPUB
[10]   A Wearable Patch to Enable Long-Term Monitoring of Environmental, Activity and Hemodynamics Variables [J].
Etemadi, Mozziyar ;
Inan, Omer T. ;
Heller, J. Alex ;
Hersek, Sinan ;
Klein, Liviu ;
Roy, Shuvo .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2016, 10 (02) :280-288