Fabrication of non-enzymatic glucose sensor dependent upon Au nanoparticles deposited on carboxylated graphene oxide

被引:51
作者
Dilmac, Yusuf [1 ]
Guler, Muhammet [2 ]
机构
[1] Van Yuzuncu Yil Univ, Inst Sci, Van, Turkey
[2] Van Yuzuncu Yil Univ, Fac Sci, Dept Chem, Van, Turkey
关键词
Carboxylated graphene oxide; Au nanoparticles; Glucose sensor; GOLD NANOPARTICLES; BIOSENSOR; ELECTRODE; COMPOSITES; MEDIA;
D O I
10.1016/j.jelechem.2020.114091
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this article, Au nanoparticles (AuNPs) were deposited on carboxylated graphene oxide (GO-COOH) for the electrochemical oxidation and enzyme-free voltammetric and amperometric determination of glucose. The GO-COOAu modified glassy carbon electrode (GCE) exhibited good sensitivity and stability toward glucose electro-oxidation in alkaline media. The surface morphology of the as-prepared nanocomposite was investigated by field emission scanning electron microscopy (FESEM) and X-ray diffraction (XRD). The electrochemical characterization of theworking electrodes was evaluated using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and amperometry. The GO-COOAu/GCE sensor provided excellent electro-catalytic performance for glucose oxidation with a linear range from 0.02 to 4.48 mM (R-2 = 0.9919) at +0.35 V, a low limit of detection (LOD) of 6 mu M, and a high sensitivity of 20.218 mu A mM(-1) cm(-2). The GO-COOAu nanocompositemodified working electrode with high sensitivity, repeatability, reproducibility, and quantification of glucose in human serumsamples made it a promising material for the development of non-enzymatic sensors.
引用
收藏
页数:9
相关论文
共 46 条
[1]   Enzyme-free glucose sensor based on a three-dimensional gold film electrode [J].
Bai, Yu ;
Yang, Weiwei ;
Sun, Ying ;
Sun, Changqing .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 134 (02) :471-476
[2]   Edge-carboxylated graphene anchoring magnetite-hydroxyapatite nanocomposite for an efficient 4-nitrophenol sensor [J].
Bharath, G. ;
Veeramani, Vediappan ;
Chen, Shen-Ming ;
Madhu, Rajesh ;
Raja, M. Manivel ;
Balamurugan, A. ;
Mangalaraj, D. ;
Viswanathan, C. ;
Ponpandian, N. .
RSC ADVANCES, 2015, 5 (18) :13392-13401
[3]   Gold nanoparticles directly modified glassy carbon electrode for non-enzymatic detection of glucose [J].
Chang, Gang ;
Shu, Honghui ;
Ji, Kai ;
Oyama, Munetaka ;
Liu, Xiong ;
He, Yunbin .
APPLIED SURFACE SCIENCE, 2014, 288 :524-529
[4]   Preparation and characterization of graphene oxide paper [J].
Dikin, Dmitriy A. ;
Stankovich, Sasha ;
Zimney, Eric J. ;
Piner, Richard D. ;
Dommett, Geoffrey H. B. ;
Evmenenko, Guennadi ;
Nguyen, SonBinh T. ;
Ruoff, Rodney S. .
NATURE, 2007, 448 (7152) :457-460
[5]   Emerging core-shell nanostructured catalysts of transition metal encapsulated by two-dimensional carbon materials for electrochemical applications [J].
Duy Thanh Tran ;
Kshetri, Tolendra ;
Dinh Chuong Nguyen ;
Gautam, Jagadis ;
Van Hien Hoa ;
Huu Tuan Le ;
Nam Hoon Kim ;
Lee, Joong Hee .
NANO TODAY, 2018, 22 :100-131
[6]   Detection of circulating tumor cells in prostate cancer based on carboxylated graphene oxide modified light addressable potentiometric sensor [J].
Gu, Yajun ;
Ju, Cheng ;
Li, Yanjun ;
Shang, Zhiqun ;
Wu, Yudong ;
Jia, Yunfang ;
Niu, Yuanjie .
BIOSENSORS & BIOELECTRONICS, 2015, 66 :24-31
[7]   Electrochemical sensing of hydrogen peroxide using Pd@Ag bimetallic nanoparticles decorated functionalized reduced graphene oxide [J].
Guler, Muhammet ;
Turkoglu, Vedat ;
Bulut, Ahmet ;
Zahmakiran, Mehmet .
ELECTROCHIMICA ACTA, 2018, 263 :118-126
[8]   A Novel Enzymatic Glucose Biosensor and Nonenzymatic Hydrogen Peroxide Sensor Based on (3-Aminopropyl) Triethoxysilane Functionalized Reduced Graphene Oxide [J].
Guler, Muhammet ;
Turkoglu, Vedat ;
Kivanc, Mehmet Riza .
ELECTROANALYSIS, 2017, 29 (11) :2507-2515
[9]   Determination of malation, methidathion, and chlorpyrifos ethyl pesticides using acetylcholinesterase biosensor based on Nafion/Ag@rGO-NH2 nanocomposites [J].
Guler, Muhammet ;
Turkoglu, Vedat ;
Basi, Zehra .
ELECTROCHIMICA ACTA, 2017, 240 :129-135
[10]   A novel glucose oxidase biosensor based on poly([2,2′; 5′,2"]-terthiophene-3′-carbaldehyde) modified electrode [J].
Guler, Muhammet ;
Turkoglu, Vedat ;
Kivrak, Arif .
INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2015, 79 :262-268