Mechanochemical N-Chlorination Reaction of Hydantoin: In Situ Real-Time Kinetic Study by Powder X-ray Diffraction and Raman Spectroscopy

被引:17
|
作者
Martins, Ines C. B. [2 ,6 ]
Carta, Maria [1 ]
Haferkamp, Sebastian [2 ]
Feiler, Torvid [2 ,3 ]
Delogu, Francesco [1 ,4 ,5 ]
Colacino, Evelina [7 ]
Emmerling, Franziska [2 ,3 ]
机构
[1] Univ Cagliari, Dipartimento Ingn Meccan Chim & Mat, I-09123 Cagliari, Italy
[2] BAM Fed Inst Mat Res & Testing, D-12489 Berlin, Germany
[3] Humboldt Univ, Dept Chem, D-12489 Berlin, Germany
[4] Consorzio Interuniv Sviluppo Sistemi Grande Inter, I-50019 Sesto Fiorentino, Italy
[5] Cagliari Res Unit, I-09123 Cagliari, Italy
[6] Univ Copenhagen, Fac Hlth & Med Sci, Dept Pharm, DK-2200 Copenhagen, Denmark
[7] Univ Montpellier, ENSCM, CNRS, ICGM, F-34090 Montpellier, France
关键词
Mechanochemistry; In situ real-time monitoring; N-Chlorination; Kinetics; Hydantoin; Powder X-ray diffraction; Raman spectroscopy; MECHANOSYNTHESIS; BALL; TEMPERATURE; AUXILIARIES; ADDITIVES; CHEMISTRY;
D O I
10.1021/acssuschemeng.1c03812
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Mechanochemistry has become a valuable tool for the synthesis of new molecules, especially in the field of organic chemistry. In the present work, we investigate the kinetic profile of the chlorination reaction of N-3-ethyl-5,5-dimethylhydantoin (EDMH) activated and driven by ball milling. The reaction has been carried out using 2 mm, 4 mm, 5 mm, 6 mm, and 8 mm ball sizes in a new small custom-made Perspex milling jar. The crystal structure of the starting material EDMH and the 1-chloro-3-ethyl-5,5'-dimethyl hydantoin (CEDMH) chlorination product was solved by single-crystal X-ray diffraction. The reaction was monitored, in situ and in real time, by both powder X-ray diffraction (PXRD) and Raman spectroscopy. Our kinetic data show that the reaction progress to equilibrium is similar at all milling ball sizes. The induction period is very short (between 10 and 40 s) when using 4 mm, 5 mm, 6 mm, and 8 mm balls. For the reaction performed with a 2 mm ball, a significantly longer induction period of 9 min was observed. This could indicate that an initial energy accumulation and higher mixing efficiency are necessary before the reaction starts. Using different kinetic models, we found that the amount of powder affected by critical loading conditions during individual impacts is significantly dependent on the ball size used. An almost linear correlation between the rate of the chemical transformations and the ball volume is observed.
引用
收藏
页码:12591 / 12601
页数:11
相关论文
共 50 条
  • [31] Study of InAs/GaAs(001) nanoisland growth process by in-situ and real-time X-ray diffraction
    Takahasi, Masamitu
    Kaizu, Toshiyuki
    Mizuki, Jun'ichiro
    E-JOURNAL OF SURFACE SCIENCE AND NANOTECHNOLOGY, 2006, 4 (426-430) : 426 - 430
  • [32] A Kinetic Study of Thermal Decomposition of Limestone Using In Situ High Temperature X-Ray Powder Diffraction
    Marinoni, Nicoletta
    Allevi, Stefano
    Marchi, Maurizio
    Dapiaggi, Monica
    JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 2012, 95 (08) : 2491 - 2498
  • [33] Structure determination of the crystalline phase of n-butanol by powder X-ray diffraction and study of intermolecular associations by Raman spectroscopy
    Derollez, Patrick
    Hedoux, Alain
    Guinet, Yannick
    Danede, Florence
    Paccou, Laurent
    ACTA CRYSTALLOGRAPHICA SECTION B-STRUCTURAL SCIENCE CRYSTAL ENGINEERING AND MATERIALS, 2013, 69 : 195 - 202
  • [34] Time-resolved in situ X-ray powder diffraction study of the formation of mesoporous silicates
    O'Brien, S
    Francis, RJ
    Fogg, A
    O'Hare, D
    Okazaki, N
    Kuroda, K
    CHEMISTRY OF MATERIALS, 1999, 11 (07) : 1822 - 1832
  • [35] TIME RESOLVED X-RAY SPECTROSCOPY - IN SITU KINETIC-EXPERIMENTS
    DARTYGE, E
    FONTAINE, A
    JUCHA, A
    TOLENTINO, H
    TOURILLON, G
    JOURNAL DE CHIMIE PHYSIQUE ET DE PHYSICO-CHIMIE BIOLOGIQUE, 1989, 86 (7-8) : 1793 - 1801
  • [36] Kinetic study of the thermal transformation of limonite to hematite by X-ray diffraction, μ-Raman and Mössbauer spectroscopy
    P. R. Palacios
    Angel Bustamante
    P. Romero-Gómez
    J. C. González
    Hyperfine Interactions, 2011, 203 : 113 - 118
  • [37] Phase transformation of barium titanate confirmed by Raman spectroscopy and powder X-ray diffraction
    Ikawa, Hiroyuki
    Nakai, Tooru
    Higuchi, Seiichi
    Saitoh, Kenichi
    Takemoto, Minoru
    Transactions of the Materials Research Society of Japan, Vol 31, No 1, 2006, 31 (01): : 101 - 104
  • [38] High-throughput powder diffraction V: the use of Raman spectroscopy with and without X-ray powder diffraction data
    Barr, Gordon
    Cunningham, Gordon
    Dong, Wei
    Gilmore, Christopher J.
    Kojima, Takashi
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2009, 42 : 706 - 714
  • [39] Investigation of the reaction mechanism of lithium sulfur batteries in different electrolyte systems by in situ Raman spectroscopy and in situ X-ray diffraction
    Zhu, W.
    Paolella, A.
    Kim, C. -S.
    Liu, D.
    Feng, Z.
    Gagnon, C.
    Trottier, J.
    Vijh, A.
    Guerfi, A.
    Mauger, A.
    Julien, C. M.
    Armandd, M.
    Zaghib, K.
    SUSTAINABLE ENERGY & FUELS, 2017, 1 (04): : 737 - 747
  • [40] Real-time in-situ X-ray beam diagnostics
    Kachatkou, Anton
    Kyele, Nicholas
    Scott, Peter
    van Silfhout, Roelof
    11TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI 2012), 2013, 425