Technical Note: Long-term stability of Hounsfield unit calibration for cone beam computed tomography

被引:9
作者
Schroder, Lukas [1 ]
Stankovic, Uros [1 ]
Sonke, Jan-Jakob [1 ]
机构
[1] Netherlands Canc Inst, Dept Radiat Oncol, NL-1066 CX Amsterdam, Netherlands
关键词
calibration; cone beam CT; Hounsfield units; SCATTER CORRECTION; CT IMAGES; RADIOTHERAPY; ACCURACY;
D O I
10.1002/mp.14015
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The goal of this study was to investigate the stability of a phantom-based Hounsfield unit (HU) calibration for cone beam CT (CBCT). Methods Three consecutive scans of a large phantom configuration and a small phantom configuration were acquired and reconstructed with a uniform scatter correction method. The CBCT gray values of the phantom inserts were measured and the three values of each insert averaged. The linear calibration curve was determined and its slope and intercept were evaluated. This procedure was performed for three CBCT scanners (Elekta Synergy) over a period of 10 months with 1, 2, or 4 weeks between measurements. A dosimetric estimation of the HU fluctuations was carried out. Results The CBCT HUs were stable over time with only small variations in slope and intercept resulting in HU differences on the water level, that is, intercepts, of less than 7 HU (standard deviation). Therefore, the dosimetric influence of these HU differences was limited. The inter-scanner disparities (up to similar to 16 HU) were larger than the intra-scanner ones (up to similar to 7 HU). Conclusions Stable HUs were observed over a period of 10 months. Due to the differences between the CBCT scanners, scanner-specific calibration curves are necessary. (c) 2020 American Association of Physicists in Medicine
引用
收藏
页码:1640 / 1644
页数:5
相关论文
共 50 条
  • [1] Deriving Hounsfield units using grey levels in cone beam computed tomography
    Mah, P.
    Reeves, T. E.
    McDavid, W. D.
    DENTOMAXILLOFACIAL RADIOLOGY, 2010, 39 (06) : 323 - 335
  • [2] A calibration method for misaligned scanner geometry in cone-beam computed tomography
    Sun, Yi
    Hou, Ying
    Zhao, Fengyong
    Hu, Jiasheng
    NDT & E INTERNATIONAL, 2006, 39 (06) : 499 - 513
  • [3] Intraoperative cone-beam computed tomography for catheter placement verification in pediatric hydrocephalus: technical note
    Krause, Matthias
    Lagumdzija, Jasmina
    Enzinger, Simon
    Wittig, Joern
    Gaggl, Alexander
    Metzger, Roman P.
    Griessenauer, Christoph J.
    CHILDS NERVOUS SYSTEM, 2024, 40 (11) : 3813 - 3816
  • [4] Iterative geometric calibration in circular cone-beam computed tomography
    Zhang, Feng
    Du, Jianping
    Jiang, Hua
    Li, Lei
    Guan, Min
    Yan, Bin
    OPTIK, 2014, 125 (11): : 2509 - 2514
  • [5] Stability of voxel values in cone-beam computed tomography
    Naitoh, Munetaka
    Aimiya, Hidetoshi
    Nakata, Kazuhiko
    Gotoh, Kenichi
    Ariji, Eiichiro
    ORAL RADIOLOGY, 2014, 30 (02) : 147 - 152
  • [6] Stability of voxel values in cone-beam computed tomography
    Munetaka Naitoh
    Hidetoshi Aimiya
    Kazuhiko Nakata
    Kenichi Gotoh
    Eiichiro Ariji
    Oral Radiology, 2014, 30 : 147 - 152
  • [7] Practical geometric calibration for helical cone-beam industrial computed tomography
    Zhang, Feng
    Yan, Bin
    Li, Lei
    Xi, Xiaoqi
    Jiang, Hua
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2014, 22 (01) : 19 - 35
  • [8] Long-term geometric quality assurance of radiation focal point and cone-beam computed tomography for Gamma Knife radiosurgery system
    Ohira, Shingo
    Imae, Toshikazu
    Minamitani, Masanari
    Katano, Atsuto
    Aoki, Atsushi
    Ohta, Takeshi
    Umekawa, Motoyuki
    Shinya, Yuki
    Hasegawa, Hirotaka
    Nishio, Teiji
    Koizumi, Masahiko
    Yamashita, Hideomi
    Saito, Nobuhito
    Nakagawa, Keiichi
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2024, 17 (02) : 389 - 395
  • [9] Geometric calibration using bundle adjustment for cone-beam computed tomography devices
    Ladikos, Alexander
    Wein, Wolfgang
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [10] A simple and precise alignment calibration method for cone-beam computed tomography with the verifications
    Shih, Kun-Long
    Jin, David Shih-Chun
    Wang, Yu-Hong
    Tran, Trang Thi Ngoc
    Chen, Jyh-Cheng
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (06)