AzBio Speech Understanding Performance in Quiet and Noise in High Performing Cochlear Implant Users

被引:15
|
作者
Brant, Jason A. [1 ]
Eliades, Steven J. [1 ]
Kaufman, Hannah [1 ]
Chen, Jinbo [2 ]
Ruckenstein, Michael J. [1 ]
机构
[1] Hosp Univ Penn, Dept Otorhinolaryngol Head & Neck Surg, 3400 Spruce St, Philadelphia, PA 19104 USA
[2] Univ Penn, Sch Med, Dept Biostat & Epidemiol, Philadelphia, PA 19104 USA
关键词
AzBio; Cochlear implant; Performance; Testing; PERCEPTION; RECOGNITION;
D O I
10.1097/MAO.0000000000001765
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective:To evaluate high-performing cochlear implant patients' performance on AzBio sentence testing.Methods:Retrospective review of prospectively collected database at a tertiary care hospital. Unilateral cochlear implant patients with AzBio testing were included. The primary outcome of interest was AzBio performance scores in quiet and at +10 and +5 decibels signal to noise (dB S/N).Results:One hundred eighty five subjects met inclusion criteria with scores for AzBio in quiet, 114 at +10dB S/N, and 66 at +5dB S/N. Linear mixed effects models showed performance significantly correlated with time since activation in all conditions (8.4%/yr; p<0.0001). Strong correlations between mean performance in quiet and at +10dB S/N (r=0.77, p<0.0001), and between +10 and +5dB S/N (r=0.73, p<0.0001) were found. The correlation between quiet and +5dB S/N (r=0.45, p=0.01) was less robust. Shapiro-Wilks test of normality found only +10dB S/N to correspond to a normal distribution. Skew analysis demonstrated values of -0.64, -0.11, and 0.8 for quiet, +10dB S/N, and +5dB S/N, respectively.Conclusions:AzBio scores at +10dB S/N show a strong correlation with, but avoid the ceiling effects that limit the usefulness of testing in quiet for high performing cochlear implant users, making it the preferred test in this population. Significant complexities exist in the study of outcomes in cochlear implant recipients, and there is no single test that is ideal for the entirety of this population.
引用
收藏
页码:571 / 575
页数:5
相关论文
共 50 条
  • [1] The effect of fluctuating maskers on speech understanding of high-performing cochlear implant users
    Zirn, Stefan
    Polterauer, Daniel
    Keller, Stefanie
    Hemmert, Werner
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2016, 55 (05) : 295 - 304
  • [2] Digit Training in Noise Can Improve Cochlear Implant Users' Speech Understanding in Noise
    Oba, Sandra I.
    Fu, Qian-Jie
    Galvin, John J., III
    EAR AND HEARING, 2011, 32 (05) : 573 - 581
  • [3] Relationship Between Speech Recognition in Quiet and Noise and Fitting Parameters, Impedances and ECAP Thresholds in Adult Cochlear Implant Users
    de Graaff, Feike
    Lissenberg-Witte, Birgit I.
    Kaandorp, Marre W.
    Merkus, Paul
    Goverts, S. Theo
    Kramer, Sophia E.
    Smits, Cas
    EAR AND HEARING, 2020, 41 (04) : 935 - 947
  • [4] Spatial Speech-in-Noise Performance in Bimodal and Single-Sided Deaf Cochlear Implant Users
    Williges, Ben
    Wesarg, Thomas
    Jung, Lorenz
    Geven, Leontien I.
    Radeloff, Andreas
    Juergens, Tim
    TRENDS IN HEARING, 2019, 23
  • [5] Electro-haptic enhancement of speech-in-noise performance in cochlear implant users
    Fletcher, Mark D.
    Hadeedi, Amatullah
    Goehring, Tobias
    Mills, Sean R.
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [6] Effect of Stimulation Rate on Speech Understanding in Older Cochlear-Implant Users
    Shader, Maureen J.
    Nguyen, Nicole
    Cleary, Miranda
    Hertzano, Ronna
    Eisenman, David J.
    Anderson, Samira
    Gordon-Salant, Sandra
    Goupell, Matthew J.
    EAR AND HEARING, 2020, 41 (03) : 640 - 651
  • [7] Speech recognition in quiet and noise in borderline cochlear implant candidates
    Alkaf, Farah Mohd
    Firszt, Jill B.
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2007, 18 (10) : 872 - 882
  • [8] The HSM Sentence Test as a tool for evaluating the speech understanding in noise of cochlear implant users
    HochmairDesoyer, I
    Schulz, E
    Moser, L
    Schmidt, M
    AMERICAN JOURNAL OF OTOLOGY, 1997, 18 (06) : S83 - S83
  • [9] Neural envelope tracking as a measure of speech understanding in cochlear implant users
    Verschueren, Eline
    Somers, Ben
    Francart, Tom
    HEARING RESEARCH, 2019, 373 : 23 - 31
  • [10] Effect of Test Realism on Speech-in-noise Outcomes in Bilateral Cochlear Implant Users
    Badajoz-Davila, Javier
    Buchholz, Jorg M.
    EAR AND HEARING, 2021, 42 (06) : 1687 - 1698