Bubble electrodeposition of gold porous nanocorals for the enzymatic and non-enzymatic detection of glucose

被引:62
作者
Sanzo, Gabriella [1 ,2 ]
Taurino, Irene [1 ]
Antiochia, Riccarda [2 ]
Gorton, Lo [3 ]
Favero, Gabriele [2 ]
Mazzei, Franco [2 ]
De Michell, Giovanni [1 ]
Carrara, Sandro [1 ]
机构
[1] Ecole Polytech Fed Lausanne, Integrated Syst Lab, CH-1015 Lausanne, Switzerland
[2] Sapienza Univ Rome, Dept Chem & Drug Technol, Biosensors Lab, Ple Aldo Moro 5, I-00185 Rome, Italy
[3] Dept Analyt Chem Biochem, POB 124, S-22100 Lund, Sweden
基金
瑞士国家科学基金会;
关键词
Hydrogen template electrodeposition; Gold nanocorals; Potassium ferricyanide; Electroactive surface area; Glucose oxidase; Glucose oxidation; DIRECT ELECTRON-TRANSFER; ELECTROCHEMICAL DETECTION; CYTOCHROME P450SCC; PALLADIUM GOLD; NANOPARTICLES; BIOSENSOR; MICROELECTRODES; SENSORS;
D O I
10.1016/j.bioelechem.2016.02.012
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Au nanocorals are grown on gold screen-printed electrodes (SPEs) by using a novel and simple one-step electro-deposition process. Scanning electron microscopy was used for the morphological characterization. The devices were assembled on a three-electrode SPE system, which is flexible and mass producible. The electroactive surface area, determined by cyclic voltammetry in sulphuric acid, was found to be 0.07 +/- 0.01 cm(2) and 35.3 +/- 2.7 cm(2) for bare Au and nanocoral Au, respectively. The nanocoral modified SPEs were used to develop an enzymatic glucose biosensor based on H2O2 detection. Au nanocoral electrodes showed a higher sensitivity of 48.3 +/- 0.9 mu A/(mM cm(2)) at + 0.45 V vs Ag vertical bar AgCl compared to a value of 24.6 +/- 13 mu A/(mM cm(2)) at + 0.70 V vs Ag vertical bar AgCl obtained with bare Au electrodes. However, the modified electrodes have indeed proven to be extremely powerful for the direct detection of glucose with a non-enzymatic approach. The results confirmed a clear peak observed by using nanocoral Au electrode even in the presence of chloride ions at physiological concentration. Amperometric study carried out at + 0.15 V vs Ag vertical bar AgCl in the presence of 0.12 M NaCl showed a linear range for glucose between 0.1 and 13 mM. (C) 2016 Published by Elsevier B.V.
引用
收藏
页码:125 / 131
页数:7
相关论文
共 47 条
[1]   Configurations used in the design of screen-printed enzymatic biosensors.: A review [J].
Albareda-Sirvent, M ;
Merkoçi, A ;
Alegret, S .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 69 (1-2) :153-163
[2]   CYP450 2B4 covalently attached to carbon and gold screen printed electrodes by diazonium salt and thiols monolayers [J].
Alonso-Lomillo, M. A. ;
Yardimci, C. ;
Dominguez-Renedo, O. ;
Arcos-Martinez, M. J. .
ANALYTICA CHIMICA ACTA, 2009, 633 (01) :51-56
[3]   Enzyme-free glucose sensor based on a three-dimensional gold film electrode [J].
Bai, Yu ;
Yang, Weiwei ;
Sun, Ying ;
Sun, Changqing .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 134 (02) :471-476
[4]   The Electrochemistry of Gold: I The Redox Behaviour of the Metal in Aqueous Media [J].
Burke, L. ;
Nugent, P. .
GOLD BULLETIN, 1997, 30 (02) :43-53
[5]   Screen-printed electrodes based on carbon nanotubes and cytochrome P450scc for highly sensitive cholesterol biosensors [J].
Carrara, Sandro ;
Shumyantseva, Victoria V. ;
Archakov, Alexander I. ;
Samori, Bruno .
BIOSENSORS & BIOELECTRONICS, 2008, 24 (01) :148-150
[6]   Biofunctionalized nanoporous gold for electrochemical biosensors [J].
Chen, L. Y. ;
Fujita, T. ;
Chen, M. W. .
ELECTROCHIMICA ACTA, 2012, 67 :1-5
[7]   Direct electrodeposition of nanoporous gold with controlled multimodal pore size distribution [J].
Cherevko, Serhiy ;
Chung, Chan-Hwa .
ELECTROCHEMISTRY COMMUNICATIONS, 2011, 13 (01) :16-19
[8]   Impact of key deposition parameters on the morphology of silver foams prepared by dynamic hydrogen template deposition [J].
Cherevko, Serhiy ;
Chung, Chan-Hwa .
ELECTROCHIMICA ACTA, 2010, 55 (22) :6383-6390
[9]   Electrodeposition of three-dimensional porous silver foams [J].
Cherevko, Serhiy ;
Xing, Xiaoli ;
Chung, Chan-Hwa .
ELECTROCHEMISTRY COMMUNICATIONS, 2010, 12 (03) :467-470
[10]   Nonenzymatic glucose detection with good selectivity against ascorbic acid on a highly porous gold electrode subjected to amalgamation treatment [J].
Cho, Sangeun ;