Electropolymerized Molecularly Imprinted Polymer Films of a Bis-Terthiophene Dendron: Folic Acid Quartz Crystal Microbalance Sensing

被引:68
|
作者
Apodaca, Dahlia C. [1 ,2 ,3 ]
Pernites, Roderick B. [1 ,2 ]
Ponnapati, Ramakrishna R. [1 ,2 ]
Del Mundo, Florian R. [3 ]
Advincula, Rigoberto C. [1 ,2 ,3 ]
机构
[1] Univ Houston, Dept Chem, Houston, TX 77204 USA
[2] Univ Houston, Dept Chem & Biomol Engn, Houston, TX 77204 USA
[3] Univ Philippines, Inst Chem, Quezon City 1101, Philippines
基金
美国国家科学基金会;
关键词
sensing; MIP; imprinting; electropolymerization; QCM; film; folic acid; IN-SITU INVESTIGATIONS; CROSS-LINKING; ELECTROCHEMICAL POLYMERIZATION; ELECTRODE SURFACES; CHEMICAL-SHIFTS; SENSOR; RECOGNITION; BINDING; MEMBRANES; NMR;
D O I
10.1021/am100805y
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A folic acid sensor was prepared via an electropolymerized molecularly imprinted polymer (E-MIP) film of a bis-terthiophene dendron on a quartz crystal microbalance (QCM). The cyclic voltammetry (CV) electrodeposition of the imprinted polymer film was monitored by electrochemical QCM or E-QCM, enabling in situ monitoring and characterization of E-MIP film formation and the viscoelastic behavior of the film. A key component of the E-MIP process is the use of a bifunctional monomer design to precomplex with the template and function as a cross-linker. The complex was electropolymerized Mid cross linked by CV to form a polythiophene Matrix. Stable cavities were formed that specifically fit the size and shape of the folic acid template. The same substrate surface was used for folic acid sensing. The predicted geometry of the 1:2 folic acid/terthiophene complex was obtained through semiempirical AM1 quantum calculations. The analytical performance, expressed through the figures of merit, of the sensor in aqueous solutions of the analyte was investigated. A relatively good linearity, R-2 = 0.985, was obtained within the concentration range 0-100 mu M folic acid. The detection limit was found to be equal to 15.4 mu M (6.8 mu g). The relative cross selectivity of the folic acid imprinted polymer against the three molecules follows this trend: pteroic acid (= 50%) > caffeine (= 41%) > theophylline (= 6%). The potential and limitations of the E-MIP method were also discussed.
引用
收藏
页码:191 / 203
页数:13
相关论文
共 44 条
  • [1] Detection of folic acid using a quartz crystal microbalance coated with molecularly imprinted polymer thin film
    Apodaca, Dahlia C.
    Pernites, Roderick B.
    Ponnapati, Ramakrishna
    Arco, Susan Dr
    Del Mundo, Florian R.
    Advincula, Rigoberto C.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 239
  • [2] Sensing the classical swine fever virus with molecularly imprinted polymer on quartz crystal microbalance
    Klangprapan, Supaporn
    Choke-arpornchai, Benjarat
    Lieberzeit, Peter A.
    Choowongkomon, Kiattawee
    HELIYON, 2020, 6 (06)
  • [3] Development of molecularly imprinted polymer films used for detection of profenofos based on a quartz crystal microbalance sensor
    Gao, Na
    Dong, Jianwei
    Liu, Ming
    Ning, Baoan
    Cheng, Chaonan
    Guo, Chun
    Zhou, Caihong
    Peng, Yuan
    Bai, Jialei
    Gao, Zhixian
    ANALYST, 2012, 137 (05) : 1252 - 1258
  • [4] Development of molecularly imprinted polymer based quartz crystal microbalance nanosensor for the determination of tryptophan
    Gultekin, Aytac
    Unuvar, Abdulkadir
    Karanfil, Gamze
    Yilmaz, Ibrahim
    Say, Ridvan
    SUPRAMOLECULAR CHEMISTRY, 2020, 32 (06) : 383 - 392
  • [5] Molecularly imprinted polymer, nanoparticles, and the quartz crystal microbalance in combination evaluate bisphenol A in water
    Sha, Xue
    Xu, Xiaohe
    Mehta, Shara
    Penn, Lynn
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 246
  • [6] Molecularly imprinted polymer-coated quartz crystal microbalance for detection of biological hormone
    Kugimiya, A
    Takeuchi, T
    ELECTROANALYSIS, 1999, 11 (15) : 1158 - 1160
  • [7] Enantioselective sensor based on microgravimetric quartz crystal microbalance with molecularly imprinted polymer film
    Cao, L
    Zhou, XC
    Li, SFY
    ANALYST, 2001, 126 (02) : 184 - 188
  • [8] Molecularly imprinted polymer based quartz crystal microbalance sensor for the clinical detection of insulin
    Kartal, Fatma
    Cimen, Duygu
    Bereli, Nilay
    Denizli, Adil
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 97 : 730 - 737
  • [9] A quartz crystal microbalance sensor based on mussel-inspired molecularly imprinted polymer
    Zhou, Wen-Hui
    Tang, Shui-Fen
    Yao, Qiu-Hong
    Chen, Fa-Rong
    Yang, Huang-Hao
    Wang, Xiao-Ru
    BIOSENSORS & BIOELECTRONICS, 2010, 26 (02): : 585 - 589
  • [10] Rapid detection of endosulfan by a molecularly imprinted polymer microsphere modified quartz crystal microbalance
    Liu, Nan
    Han, Jianguang
    Liu, Zhen
    Qu, Lijie
    Gao, Zhixian
    ANALYTICAL METHODS, 2013, 5 (17) : 4442 - 4447