Fibular Strut Graft Augmentation for Open Reduction and Internal Fixation of Proximal Humerus Fractures: A Systematic Review and the Authors' Preferred Surgical Technique

被引:28
作者
Saltzman, Bryan M. [1 ,2 ]
Erickson, Brandon J. [1 ,2 ]
Harris, Joshua D. [1 ,3 ]
Gupta, Anil K. [1 ,4 ]
Mighell, Mark [1 ,5 ]
Romeo, Anthony A. [1 ,2 ]
机构
[1] Rush Univ, Med Ctr, Chicago, IL 60612 USA
[2] Rush Univ, Med Ctr, Midwest Orthopaed Rush, 1611 West Harrison St,Suite 300, Chicago, IL 60612 USA
[3] Houston Methodist Hosp, Dept Orthoped & Sports Med, Houston, TX USA
[4] Univ Toledo, Dept Orthopaed, Toledo Orthopaed Surg, 2801 W Bancroft St, Toledo, OH 43606 USA
[5] Florida Orthopaed Inst, Tampa, FL USA
关键词
proximal humerus fracture; fibular strut; open reduction internal fixation; surgical; shoulder; LOCKING PLATE; UNSTABLE FRACTURES; CLASSIFICATION; EPIDEMIOLOGY; OUTCOMES; RISK;
D O I
10.1177/2325967116656829
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Proximal humerus fractures are common problems plaguing the elderly population. Purpose: The purposes of this study were to determine the outcomes of fibular strut allografts in treatment of proximal humerus fractures with open reduction internal fixation (ORIF) and to present the authors' preferred surgical technique. The hypothesis was that the use of fibular strut allografts in treating proximal humerus fractures with ORIF will provide low reoperation rates with acceptable outcomes. Study Design: Systematic review; Level of evidence, 4. Methods: A systematic review was registered with PROSPERO and performed with PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) guidelines using 3 publicly available free databases. Therapeutic clinical outcome investigations reporting arthroscopic elbow outcomes with levels of evidence 1 through 4 were eligible for inclusion. All study, subject, and surgical technique demographics were analyzed and compared between continents and countries. Statistics were calculated using Student t tests, 1-way analysis of variance, chi-square tests, and 2-proportion Z tests. Results: Four studies met the inclusion criteria. While there is great heterogeneity existing in the literature surrounding use of a fibular strut allograft as an adjunct to ORIF of proximal humerus fractures, current evidence shows a humeral head screw penetration rate of 3.7% with acceptable functional outcome scores, with a reoperation rate of 4.4% at a weighted mean 80.78 weeks (1.55 years) of postoperative follow-up. Conclusion: There is great heterogeneity that exists in the literature surrounding the use of a fibular strut allograft as an adjunct to ORIF of proximal humerus fractures. Current evidence shows a screw penetration rate of 3.7% with acceptable functional outcome scores, demonstrating fibular strut allograft is a viable option for treating proximal humerus fractures.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Open reduction and internal fixation versus minimally invasive plate osteosynthesis of unstable proximal humerus fractures treated with locking plate and intramedullary allograft: A retrospective study
    Rusimov, Lyubomir
    Baltov, Asen
    Enchev, Dian
    Gueorguiev, Boyko
    Prodanova, Krasimira
    Hadzhinikolova, Mariya
    Rusimov, Vladimir
    Rashkov, Mihail
    [J]. SHOULDER & ELBOW, 2024,
  • [42] Three-dimensional printing combined with open reduction and internal fixation versus open reduction and internal fixation in the treatment of acetabular fractures: A systematic review and meta-analysis
    Tu, Dong-Peng
    Yu, Yi-Kang
    Liu, Zhen
    Zhang, Wen-Kai
    Fan, Xin
    Xu, Chao
    [J]. CHINESE JOURNAL OF TRAUMATOLOGY, 2021, 24 (03) : 159 - 168
  • [43] Biomechanical evaluation of a new fixation technique for internal fixation of three-part proximal humerus fractures in a novel cadaveric model
    Brianza, Stefano
    Plecko, Michael
    Gueorguiev, Boyko
    Windolf, Markus
    Schwieger, Karsten
    [J]. CLINICAL BIOMECHANICS, 2010, 25 (09) : 886 - 892
  • [44] INTERNAL-FIXATION OF PROXIMAL HUMERUS FRACTURES USING THE SCREW-TENSION BAND TECHNIQUE
    CORNELL, CN
    LEVINE, D
    PAGNANI, MJ
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 1994, 8 (01) : 23 - 27
  • [45] Surgical Management of Complex Proximal Humerus Fractures-A Systematic Review of 92 Studies Including 4500 Patients
    Gupta, Anil K.
    Harris, Joshua D.
    Erickson, Brandon J.
    Abrams, Geoffrey D.
    Bruce, Benjamin
    McCormick, Frank
    Nicholson, Gregory P.
    Romeo, Anthony A.
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2015, 29 (01) : 54 - 59
  • [46] Simultaneous Reverse Shoulder Arthroplasty and Open Reduction With Internal Fixation for Bilateral Proximal Humerus Fractures in the Elderly: A Report of Two Cases
    Sato, Kai
    Hatta, Taku
    Shinagawa, Kiyotsugu
    Okuno, Hiroshi
    Nobuta, Shingo
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (09)
  • [47] Strategies for Surgical Approaches in Open Reduction Internal Fixation of Pilon Fractures
    Assal, Mathieu
    Ray, Adrien
    Stern, Richard
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2015, 29 (02) : 69 - 79
  • [48] Timing of surgery for open reduction and internal fixation of displaced proximal humeral fractures
    Siebenbuerger, Georg
    Van Delden, Dustin
    Helfen, Tobias
    Haasters, Florian
    Boecker, Wolfgang
    Ockert, Ben
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 : S58 - S62
  • [49] Open Reduction and Internal Fixation of Mandibular Condylar Base and Neck Fractures Using Strut Plates
    Lechler, Carolin
    Probst, Florian
    Cornelius, Carl-Peter
    Smolka, Wenko
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2018, 76 (07) : 1494 - 1503
  • [50] Technique of Kirschner Wire Reduction and Fixation of Displaced Two-Part Valgus Angulated Proximal Humerus Fractures at the Surgical Neck
    Seyhan, Mustafa
    Kocaoglu, Baris
    Nalbantoglu, Ufuk
    Aydin, Nuri
    Guven, Osman
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (06) : E46 - E50