Diagnosis of Open Circuit Faults for Three-Phase Three-Level Converters Based on the Change Rate of Current Residual

被引:2
作者
Gong, Zi [1 ]
He, Xiaoqiong [1 ]
Han, Pengcheng [1 ]
机构
[1] Southwest Jiaotong Univ, Sch Elect Engn, Chengdu, Peoples R China
来源
PROCEEDINGS OF THE 2021 IEEE 16TH CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA 2021) | 2021年
基金
中国国家自然科学基金;
关键词
three-phaxe; three-level; rectifier; fault diagnosis; mired logic dynamic model; the change rate of current residual;
D O I
10.1109/ICIEA51954.2021.9516070
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
To realize the diagnosis for IGBT open-circuit faults in a three-phase three-level rectifier, a fault diagnosis based on the change rate of current residual is proposed. Firstly, a mixed logic dynamic(MLD) model of the rectifier was established to generate the residual of the grid current. And then, combining the theoretical calculation with the simulation results, the change rate of current residual and the residual characteristics for different IGBT faults were analyzed. Then, the normalized diagnostic variables and the threshold were defined to accomplish fault detection for the single RAFT opencircuit faults in different situations. Finally, the validity of the diagnostic method was verified through MATLAB/Simulink simulation.
引用
收藏
页码:861 / 866
页数:6
相关论文
共 9 条
[1]  
An Q. T., 2011, T CHINA ELECTROTECHN, V24, P135
[2]  
[葛兴来 Ge Xinglai], 2016, [铁道学报, Journal of the China Railway Society], V38, P35
[3]  
Peng Lijun, 2018, Electrical Measurement and Instrumentation, V55, P110
[4]  
Wang Xin., 2016, ELECT MEASUREMENT TE, V6, P159
[5]  
[王亚飞 Wang Yafei], 2015, [电源学报, Journal of Power Supply], V13, P45
[6]  
Wu Juan, 2015, Advanced Technology of Electrical Engineering and Energy, V34, P48
[7]  
Xie D., 2017, CONTROL INFORM TECHN, V4, P75
[8]  
[谢东 Xie Dong], 2018, [电工技术学报, Transactions of China Electrotechnical Society], V33, P3822
[9]  
[杨颢 Yang Hao], 2018, [铁道科学与工程学报, Journal of Rail Way Science and Engineering], V15, P2131