Heat transfer and pressure drop measurements in rib-roughened rectangular ducts

被引:128
作者
Gao, XF [1 ]
Sundén, B [1 ]
机构
[1] Lund Inst Technol, Div Heat Transfer, S-22100 Lund, Sweden
关键词
liquid crystal thermography; heat transfer enhancement; pressure drop; rib-roughened duct;
D O I
10.1016/S0894-1777(00)00054-6
中图分类号
O414.1 [热力学];
学科分类号
摘要
In the present study, the thermal and hydraulic performance of three rib-roughened rectangular ducts is investigated. The aspect ratio of the ducts was 1 to 8, and the ribs were arranged staggered on the two wide walls. Three rib configurations were tested: parallel ribs and V-shaped ribs pointing upstream or downstream of the main flow direction. For all cases, the rib height-to-hydraulic diameter ratio was 0.06, with an attack angle of 60 degrees and a pitch-to-height ratio of 10. The Reynolds number range was from 1000 to 6000. Liquid crystal thermography was employed in the heat transfer experiment to demonstrate detailed temperature distribution between a pair of ribs on the ribbed surfaces. The secondary flows caused by the inclined ribs create a significant spanwise variation of the heat transfer coefficients on the rib-roughened wall with high heat transfer coefficient at one end of the rib and low value at the other. In the streamwise direction between two consecutive ribs, the temperature distribution shows a sawtooth fashion because of flow reattachment. Based on the local heat transfer coefficients, the average Nusselt numbers were estimated as weighted mean values. Isothermal pressure drop data were taken and presented as Fanning friction factors. The ducts are compared to each other by considering both heat transfer and friction factor performance. (C) 2001 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:25 / 34
页数:10
相关论文
共 21 条
[1]  
BOX GEP, 1978, STAT EXPT INTRO DESI, P453
[2]   Heat transfer in a reciprocating duct fitted with transverse ribs [J].
Chang, SW ;
Su, LM ;
Hwang, CC ;
Yang, TL .
EXPERIMENTAL HEAT TRANSFER, 1999, 12 (02) :95-115
[3]  
Fiebig M., 1996, P 2 EUR THERM SCI C, P41
[4]  
GAO X, 2001, IN PRESS HETA MASS T
[5]  
GAO X, 2000, 34 NAT HEAT TRANSF C
[6]   Detailed measurements of heat transfer coefficients in a rectangular duct using hue-based calibrated liquid crystal [J].
Gao, XF ;
Sundén, B .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2000, 27 (01) :13-22
[7]   DEVELOPING HEAT-TRANSFER IN RECTANGULAR CHANNELS WITH RIB TURBULATORS [J].
HAN, JC ;
PARK, JS .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1988, 31 (01) :183-195
[8]   AUGMENTED HEAT-TRANSFER IN SQUARE CHANNELS WITH PARALLEL, CROSSED, AND V-SHAPED ANGLED RIBS [J].
HAN, JC ;
ZHANG, YM ;
LEE, CP .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1991, 113 (03) :590-596
[9]   IMPROVEMENT IN CALCULATION OF TURBULENT FRICTION IN RECTANGULAR DUCTS [J].
JONES, OC .
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 1976, 98 (02) :173-181
[10]  
Kakac S., 1987, HDB SINGLE PHASE CON