Treatment of Complex Intracranial Aneurysms Using Flow-Diverting Silk® Stents An Analysis of 32 Consecutive Patients

被引:15
作者
Buyukkaya, Ramazan [1 ]
Kocaeli, Hasan [2 ]
Yildirim, Nalan [3 ]
Cebeci, Hakan [3 ]
Erdogan, Cuneyt [3 ]
Hakyemez, Bahattin [3 ]
机构
[1] Duzce Univ, Sch Med, Dept Radiol, TR-81100 Duzce, Turkey
[2] Uludag Univ, Sch Med, Dept Neurosurg, Bursa, Turkey
[3] Uludag Univ, Sch Med, Dept Radiol, Bursa, Turkey
关键词
cerebral aneurysms; flow diverter; Silk stent; endovascular treatment; ENDOVASCULAR TREATMENT; CEREBRAL ANEURYSMS; EMBOLIZATION DEVICE; FOLLOW-UP; EXPERIENCE; RECONSTRUCTION; EFFICACY; ARTERY; SAFETY;
D O I
10.15274/INR-2014-10070
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
This study describes the pen-procedural and late complications and angiographic follow-up results of 32 patients with 34 complex aneurysms treated with flow diverter Silk stents in a single centre. In this retrospective study, 40 Silk stents (SS) were implanted in 34 complex intracranial aneurysms in 32 patients. In our series, 20 (58.8%) carotid-ophthalmic internal carotid artery (ICA), six (17.6%) cavernous ICA, two (5.9%) supraclinoid ICA, two (5.9%) petrosal ICA (the same patient-bilateral) and four (11.8%) posterior circulation aneurysms were treated. One of the posterior circulation lesions was a fenestrated-type aneurysm. Twenty wide-necked, saccular; eight neck remnant; four fusiform and two blister-like aneurysms were included in our series. SS were successfully implanted in all patients (100%). Mis-deployment occurred in 17.6% of patients. In two of these patients adequate stent openness was achieved via Hyperglide balloon dilatation. Coil embolization in addition to SS placement was utilized in four aneurysms. One patient (3%) experienced transient morbidity due to a thromboembolic event and there was one mortality (3%) due to remote intraparenchymal haemorrhage. Complete occlusion of 27/33 (81.8 %) and 29/33 (87.9 %) aneurysms was achieved six and 12 months after the procedure, respectively. In-stent intimal hyperplasia was detected in 6.1 % patients. Flow-diverter Silk stent implantation is an effective method of treating complex aneurysms with acceptable mortality and morbidity rates. Complete occlusion is achieved in most of the complex aneurysms.
引用
收藏
页码:729 / 735
页数:7
相关论文
共 25 条
[1]   Infectious Aneurysm of the Cavernous Carotid Artery in a Child Treated With a New-Generation of Flow-Diverting Stent Graft: Case Report [J].
Appelboom, Geoffrey ;
Kadri, Khaled ;
Hassan, Farouk ;
Leclerc, Xavier .
NEUROSURGERY, 2010, 66 (03) :E623-U214
[2]   Flow-Diverter Devices for Intracranial Aneurysms: Systematic Review and Meta-analysis [J].
Arrese, Ignacio ;
Sarabia, Rosario ;
Pintado, Rebeca ;
Delgado-Rodriguez, Miguel .
NEUROSURGERY, 2013, 73 (02) :193-199
[3]   Flow-Diverter Silk Stent for the Treatment of Intracranial Aneurysms: 1-year Follow-Up in a Multicenter Study [J].
Berge, J. ;
Biondi, A. ;
Machi, P. ;
Brunel, H. ;
Pierot, L. ;
Gabrillargues, J. ;
Kadziolka, K. ;
Barreau, X. ;
Dousset, V. ;
Bonafe, A. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (06) :1150-1155
[4]   Italian multicenter experience with flow-diverter devices for intracranial unruptured aneurysm treatment with periprocedural complications-a retrospective data analysis [J].
Briganti, Francesco ;
Napoli, Manuela ;
Tortora, Fabio ;
Solari, Domenico ;
Bergui, Mauro ;
Boccardi, Edoardo ;
Cagliari, Enrico ;
Castellan, Lucio ;
Causin, Francesco ;
Ciceri, Elisa ;
Cirillo, Luigi ;
De Blasi, Roberto ;
Delehaye, Luigi ;
Di Paola, Francesco ;
Fontana, Andrea ;
Gasparotti, Roberto ;
Guidetti, Giulio ;
Divenuto, Ignazio ;
Iannucci, Giuseppe ;
Isalberti, Maurizio ;
Leonardi, Marco ;
Lupo, Fernando ;
Mangiafico, Salvatore ;
Manto, Andrea ;
Menozzi, Roberto ;
Muto, Mario ;
Nuzzi, Nunzio Paolo ;
Papa, Rosario ;
Petralia, Benedetto ;
Piano, Mariangela ;
Resta, Maurizio ;
Padolecchia, Riccardo ;
Saletti, Andrea ;
Sirabella, Giovanni ;
Bolge, Luca Piero Valvassori .
NEURORADIOLOGY, 2012, 54 (10) :1145-1152
[5]   Endovascular Treatment of Intracranial Aneurysms With Flow Diverters A Meta-Analysis [J].
Brinjikji, Waleed ;
Murad, Mohammad H. ;
Lanzino, Giuseppe ;
Cloft, Harry J. ;
Kallmes, David F. .
STROKE, 2013, 44 (02) :442-447
[6]   Definitive reconstruction of circumferential fusiform intracranial aneurysms with the pipeline embolization device [J].
Fiorella, David ;
Woo, Henry H. ;
Albuquerque, Felipe C. ;
Nelson, Peter K. .
NEUROSURGERY, 2008, 62 (05) :1115-1120
[7]   The Asymmetric Vascular Stent Efficacy in a Rabbit Aneurysm Model [J].
Ionita, Ciprian N. ;
Paciorek, Ann M. ;
Dohatcu, Andreea ;
Hoffmann, Kenneth R. ;
Bednarek, Daniel R. ;
Kolega, John ;
Levy, Elad I. ;
Hopkins, L. Nelson ;
Rudin, Stephen ;
Mocco, J. Duffy .
STROKE, 2009, 40 (03) :959-965
[8]  
Jiang WJ, 2007, AM J NEURORADIOL, V28, P830
[9]  
Katsaridis V, 2006, AM J NEURORADIOL, V27, P1123
[10]   Efficacy and current limitations of intravascular stents for intracranial internal carotid, vertebral, and basilar artery aneurysms [J].
Lanzino, G ;
Wakhloo, AK ;
Fessler, RD ;
Hartney, ML ;
Guterman, LR ;
Hopkins, LN .
JOURNAL OF NEUROSURGERY, 1999, 91 (04) :538-546