Design of an electrochemical platform for the determination of diclofenac sodium utilizing a graphenized pencil graphite electrode modified with a Cu-Al layered double hydroxide/chicken feet yellow membrane

被引:13
作者
Bahadori, Younes [1 ]
Razmi, Habib [1 ]
机构
[1] Azarbaijan Shahid Madani Univ, Fac Basic Sci, Dept Chem, POB 53714-161, Tabriz, Iran
关键词
LIQUID-FUNCTIONALIZED GRAPHENE; SOLID-PHASE EXTRACTION; POTENTIOMETRIC SENSOR; OXIDE; NANOPARTICLES; ADSORPTION; H2O2;
D O I
10.1039/d1nj02258j
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A novel electrochemical sensor based on a Cu-Al layered double hydroxide (Cu-Al LDH)/chicken feet yellow membrane (CFYM) modified graphenized pencil graphite electrode (GPGE) was designed. The present modified electrode provides a simple voltammetric method for the sensitive detection of diclofenac (DCF) for the first time. In the first stage, a one-step potentiostatic method was utilized for the in situ synthesis of graphene oxide directly on the PGE surface in H2SO4 solution under optimized conditions. Then certain values of Cu-Al LDH (synthesized via a co-precipitation method), and CFYM dispersion in dimethylformamide was homogenized by sonication for 60 min. Finally, 10 mu L of resulting dispersion was drop-cast on the surface of the GPGE. The structure and morphology of the surface of the modified electrode were characterized using SEM and XRD techniques. Compared with the unmodified pencil graphite electrode, the Cu-Al LDH/CFYM/GPGE modified electrode showed an enhanced electrochemical response toward DCF oxidation using cyclic voltammetry (CV) and differential pulse voltammetric (DPV) techniques. The effect of parameters such as the scan rate and pH value on the peak current was studied. Under the optimized conditions, the Cu-Al LDH/CFYM/GPGE showed a linear current response for the oxidation of DCF in the range of 1.99-23.44 mu M. The sensitivity, limit of detection (LOD), and limit of quantification (LOQ) of the proposed sensor for the detection of the DCF were calculated to be 6.02 mu A mu M-1, 1.91 mu M, and 6.39 mu M, respectively. Moreover, the modified electrode was successfully examined for the detection of DCF in real samples.
引用
收藏
页码:14616 / 14625
页数:10
相关论文
共 63 条
[1]   New insights on diclofenac electrochemistry using graphite as working electrode [J].
Aguilar-Lira, G. Y. ;
Alvarez-Romero, G. A. ;
Zamora-Suarez, A. ;
Palomar-Pardave, M. ;
Rojas-Hernandez, A. ;
Rodriguez-Avila, J. A. ;
Paez-Hernandez, M. E. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 794 :182-188
[2]   Adsorption and anion exchange insight of indigo carmine onto CuAl-LDH/SWCNTs nanocomposite: kinetic, thermodynamic and isotherm analysis [J].
Almoisheer, Noha ;
Alseroury, F. A. ;
Kumar, Rajeev ;
Aslam, M. ;
Barakat, M. A. .
RSC ADVANCES, 2019, 9 (01) :560-568
[3]   Electrochemical determination of pharmaceuticals in spiked water samples [J].
Ambrosi, A ;
Antiochia, R ;
Campanella, L ;
Dragone, R ;
Lavagnini, I .
JOURNAL OF HAZARDOUS MATERIALS, 2005, 122 (03) :219-225
[4]   Spectrofluorimetric determination of diclofenac in the presence of α-cyclodextrin [J].
Arancibia, JA ;
Boldrini, MA ;
Escandar, GM .
TALANTA, 2000, 52 (02) :261-268
[5]   MWCNTs/Cu(OH)2 nanoparticles/IL nanocomposite modified glassy carbon electrode as a voltammetric sensor for determination of the non-steroidal anti-inflammatory drug diclofenac [J].
Arvand, Majid ;
Gholizadeh, Tahereh M. ;
Zanjanchi, Mohammad Ali .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2012, 32 (06) :1682-1689
[6]   Applications of layered double hydroxides based electrochemical sensors for determination of environmental pollutants: A review [J].
Baig, Nadeem ;
Sajid, Muhammad .
TRENDS IN ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2017, 16 :1-15
[7]   Cu/Al and Cu/Cr based layered double hydroxide nanoparticles as adsorption materials for water treatment [J].
Berner, Stefan ;
Araya, Paulo ;
Govan, Joseph ;
Palza, Humberto .
JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2018, 59 :134-140
[8]   2D Layered Double Hydroxide Nanoparticles: Recent Progress toward Preclinical/Clinical Nanomedicine [J].
Cao, Zhenbang ;
Li, Bei ;
Sun, Luyao ;
Li, Li ;
Xu, Zhi Ping ;
Gu, Zi .
SMALL METHODS, 2020, 4 (02)
[9]   Disk-based solid phase extraction for the determination of diclofenac and steroidal estrogens E1, E2 and EE2 listed in the WFD watch list by GC-MS [J].
Cesen, Marjeta ;
Heath, Ester .
SCIENCE OF THE TOTAL ENVIRONMENT, 2017, 590 :832-837
[10]   Layered double hydroxide based bionanocomposites [J].
Chatterjee, Aniruddha ;
Bharadiya, Preetam ;
Hansora, Dharmesh .
APPLIED CLAY SCIENCE, 2019, 177 :19-36