Initial clinical results with a new needle screen storage phosphor system in chest radiograms

被引:22
作者
Körner, M [1 ]
Wirth, S [1 ]
Treitl, M [1 ]
Reiser, M [1 ]
Pfeifer, KJ [1 ]
机构
[1] Univ Munich, Inst Klin Radiol, Munich, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2005年 / 177卷 / 11期
关键词
radiation safety; technical aspects; technology assessment; radiography; thorax; digital radiography;
D O I
10.1055/s-2005-858687
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate image quality and anatomical detail depiction in dose-reduced digital plain chest radiograms using a new needle screen storage phosphor (NIP) in comparison to full dose conventional powder screen storage phosphor (PIP) images. Materials and Methods: 24 supine chest radiograms were obtained with PIP at standard dose and compared to follow-up studies of the same patients obtained with NIP with dose reduced to 50% of the PIP dose (all imaging systems: AGFA-Gevaert, Mortsel, Belgium). In both systems identical versions of post-processing software supplied by the manufacturer were used with matched parameters. Six independent readers blinded to both modality and dose evaluated the images for depiction and differentiation of defined anatomical regions (peripheral lung parenchyma, central lung parenchyma, hilum, heart, diaphragm, upper mediastinum, and bone). All NIP images were compared to the corresponding PIP images using a five-point scale (- 2, clearly inferior to + 2, clearly superior). Overall image quality was rated for each PIP and NIP image separately (1, not usable to 5, excellent). Results: PIP and dose reduced NIP images were rated equivalent. Mean image noise impression was only slightly higher on NIP images. Mean image quality for NIP showed no significant differences (p > 0.05, Mann-Whitney U test). Conclusion: With the use of the new needle structured storage phosphors in chest radiography, dose reduction of up to 50% is possible without detracting from image quality or detail depiction. Especially in patients with multiple follow-up studies the overall dose can be decreased significantly.
引用
收藏
页码:1491 / 1496
页数:6
相关论文
共 21 条
[1]   Comparison of low contrast detectability between a digital amorphous silicon and a screen-film based imaging system for thoracic radiography [J].
Aufrichtig, R .
MEDICAL PHYSICS, 1999, 26 (07) :1349-1358
[2]   Dose reduction in patients undergoing chest imaging: Digital amorphous silicon flat-panel detector radiography versus conventional film-screen radiography and phosphor-based computed radiography [J].
Bacher, K ;
Smeets, P ;
De Hauwere, A ;
Verstraete, K ;
Thierens, H .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (04) :923-929
[3]   Detection of simulated interstitial lung disease and catheters with selenium, storage phosphor, and film-based radiography [J].
Bernhardt, TM ;
Otto, D ;
Reichel, G ;
Ludwig, K ;
Seifert, S ;
Kropf, S ;
Rapp-Bernhardt, U .
RADIOLOGY, 1999, 213 (02) :445-454
[4]   Image quality and exposure dose in digital projection radiography [J].
Busch, HP ;
Busch, S ;
Decker, C ;
Schilz, C .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (01) :32-37
[5]   New computed radiography technologies in digital radiography [J].
Fasbender, R ;
Schaetzing, R .
RADIOLOGE, 2003, 43 (05) :367-373
[6]  
FRANKENBERGER J, 2005, P SOC PHOTO-OPT INS, P499
[7]   Reduction of radiation dose by using digital luminescence radiography compared to conventional screen film system with grid cassette. [J].
Heyne, JP ;
Merbold, H ;
Sehner, J ;
Neumann, R ;
Freesmeyer, M ;
Jonetz-Mentzel, L ;
Kaiser, WA .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 171 (01) :54-59
[8]   Reduction of radiation dose by using digital luminescence radiography on a hand phantom. [J].
Heyne, JP ;
Merbold, H ;
Sehner, J ;
Neumann, R ;
Adler, R ;
Freesmeyer, M ;
Kaiser, WA .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (04) :386-390
[9]   Reduction of radiation exposure by using storage phosphor radiography on pelvis and lumbar spine [J].
Heyne, JR ;
Sehner, J ;
Neumann, R ;
Werner, B ;
Adler, R ;
Freesmeyer, M ;
Kaiser, WA .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (01) :104-111
[10]  
ILLERS H, 2004, P SOC PHOTO-OPT INS, P177