MECHANISM OF "FLAP CLOSURE" AFTER THE INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUE

被引:57
作者
Boninska, Karolina [1 ]
Nawrocki, Jerzy [1 ,2 ]
Michalewska, Zofia [1 ,2 ]
机构
[1] Ophthalm Clin Jasne Blonia, Dept Ophthalmol, Lodz, Poland
[2] Dr K Jonscher Municipal Med Ctr, Lodz, Poland
来源
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES | 2018年 / 38卷 / 11期
关键词
flap closure; inverted ILM flap technique; macular hole; vitrectomy; OPTICAL COHERENCE TOMOGRAPHY; IDIOPATHIC MACULAR HOLES; RETINAL-DETACHMENT; THICKNESS MEASUREMENTS; SURGICAL OUTCOMES; SURGERY; EFFICACY;
D O I
10.1097/IAE.0000000000001861
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Recent studies described that in approximately 14% to 16% of cases of macular holes treated with the inverted internal limiting membrane flap technique, the hole was closed only by a thin layer of inverted internal limiting membrane-"flap closure." The aim of this article was to describe the functional and anatomical results in flap closure macular holes and also the mechanism of flap closure. Methods: A retrospective observational study of 149 eyes of 139 patients treated with vitrectomy using the inverted internal limiting membrane flap technique was reviewed to aggregate eyes with flap closure. Complete ophthalmic examination was performed preoperatively and at 7 days, 1, 3, 6, and 12 months after surgery. Results: Flap closure (Group 1) was noted in 24 eyes and other closure types in 125 eyes (Group 2). The mean minimal and base diameters of the macular holes in the flap closure group were greater than those in Group 2 (P < 0.001). The mean postoperative best-corrected visual acuity in the flap closure group (20/100) was lower than that in Group 2 (20/50) (P < 0.001). Conclusion: Flap closure probably enables closure of large macular holes with a higher probability of remaining open without the use of the inverted internal limiting membrane flap technique. Foveal architecture continuously improved.
引用
收藏
页码:2184 / 2189
页数:6
相关论文
共 23 条
[1]   MACULAR HOLES [J].
AABERG, TM ;
BLAIR, CJ ;
GASS, DM .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1970, 69 (04) :555-&
[2]   EFFICACY OF THE INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUE WITH VITRECTOMY FOR RETINAL DETACHMENT ASSOCIATED WITH MYOPIC MACULAR HOLES [J].
Baba, Ryo ;
Wakabayashi, Yoshihiro ;
Umazume, Kazuhiko ;
Ishikawa, Tomoaki ;
Yagi, Hiromichi ;
Muramatsu, Daisuke ;
Goto, Hiroshi .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2017, 37 (03) :466-471
[3]   Inverted Internal Limiting Membrane Insertion for Macular Hole Associated Retinal Detachment in High Myopia [J].
Chen, San-Ni ;
Yang, Chung-May .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2016, 162 :99-106
[4]   Systemic risk factors for idiopathic macular holes: a case-control study [J].
Evans, JR ;
Schwartz, SD ;
McHugh, JDA ;
Thamby-Rajah, Y ;
Hodgson, SA ;
Wormald, RPL ;
Gregor, ZJ .
EYE, 1998, 12 (2) :256-259
[5]   FOVEAL MICROSTRUCTURE IN MACULAR HOLES SURGICALLY CLOSED BY INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUE [J].
Hayashi, Hisako ;
Kuriyama, Shoji .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2014, 34 (12) :2444-2450
[6]   Comparison of manually corrected retinal thickness measurements from multiple spectral-domain optical coherence tomography instruments [J].
Heussen, Florian M. ;
Ouyang, Yanling ;
McDonnell, Emma C. ;
Narala, Ramsudha ;
Ruiz-Garcia, Humberto ;
Walsh, Alexander C. ;
Sadda, SriniVas R. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2012, 96 (03) :380-385
[7]   Optical coherence tomography of successfully repaired idiopathic macular holes [J].
Imai, M ;
Iijima, H ;
Gotoh, T ;
Tsukahara, S .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1999, 128 (05) :621-627
[8]   Types of macular hole closure and their clinical implications [J].
Kang, SW ;
Ahn, K ;
Ham, DI .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2003, 87 (08) :1015-1019
[9]   VITREOUS SURGERY FOR IDIOPATHIC MACULAR HOLES - RESULTS OF A PILOT-STUDY [J].
KELLY, NE ;
WENDEL, RT .
ARCHIVES OF OPHTHALMOLOGY, 1991, 109 (05) :654-659
[10]   Long-term surgical outcomes of the inverted internal limiting membrane flap technique in highly myopic macular hole retinal detachment [J].
Kinoshita, Taiga ;
Onoda, Yasutaka ;
Maeno, Takatoshi .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 255 (06) :1101-1106