Measurement of glomerular filtration rate with chromium-51 ethylene diamino tetraacetic acid in the presence of gallium-67 citrate: a novel method for the solution of the problem

被引:2
作者
Arsos, Georgios [1 ]
Moralidis, Efstratios [2 ]
Tsechelidis, Ioannis [1 ]
Sakagiannis, Georgios [1 ]
Sidiropoulou, Vasiliki [3 ]
Psarouli, Efthimia [1 ]
机构
[1] Aristotle Univ Thessaloniki, Hippokrat Hosp, Sch Med, Dept Nucl Med, Thessaloniki 55236, Greece
[2] Aristotle Univ Thessaloniki, AHEPA Univ Hosp, Sch Med, Dept Nucl Med, Thessaloniki 55236, Greece
[3] Hippokrateion Hosp, Dept Pediat Oncol, Thessaloniki, Greece
关键词
chromium-51-ethylene diamino tetraacetic acid; crosstalk interference; gallium-67; glomerular filtration rate; radionuclide mixture; GFR MEASUREMENT; SCINTIGRAPHY; GUIDELINES; GA-67;
D O I
10.1097/MNM.0b013e328342b969
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Chromium-51 (Cr-51)-ethylene diamino tetraacetic acid plasma clearance is commonly used in glomerular filtration rate measurements. In the presence of additional radionuclides in plasma samples, glomerular filtration rate may be seriously underestimated and a correction of the crosstalk interference may be necessary. This type of correction is problematic in the case of gallium-67 (Ga-67) mainly because of the close vicinity of its 300 keV photopeak with that of the 320 keV photopealc of Cr-51. A novel method of calculating and removing the interfering Ga-67 counts within the Cr-51 counting window, based on the different decay rates of the two radionuclides, is presented, requiring two series of sample counting in the Cr-51 counting window only, separated by a 3-day interval. This method was developed to solve a clinical problem and then it was validated by a controlled Ga-67 coniamination of plasma samples with known counts from Cr-51-ethylene diamino tetraacetic acid. Nucl Med Commun 32:227-232 (C) 2011 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
引用
收藏
页码:227 / 232
页数:6
相关论文
共 18 条
[1]  
[Anonymous], 2009, TECHN REP SER IAEA, V468
[2]  
[Anonymous], 2008, EV MEAS DAT GUID EXP
[3]  
Arsos G, 2010, EUR J NUCL MED MOL I, V37, pS465
[4]  
Arsos G, 2009, EUR J NUCL MED MO S1, V36, P5439
[5]  
Ayhanci A, 2009, BIOL TRACE ELEM RES
[6]   GFR measurement with iohexol and 51Cr-EDTA.: A comparison of the two favoured GFR markers in Europe [J].
Brandstrom, E ;
Grzegorczyk, A ;
Jacobsson, L ;
Friberg, P ;
Lindahl, A ;
Aurell, M .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1998, 13 (05) :1176-1182
[8]  
Cherry S. R., 2012, Physics in Nuclear Medicine
[9]   Gallium-67 scintigraphy: a cornerstone in functional imaging of lymphoma [J].
Even-Sapir, Einat ;
Israel, Ora .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (Suppl 1) :S65-S81
[10]   Quality control of slope-intercept measurements of glomerular filtration rate using single-sample estimates [J].
Fleming, JS ;
Persaud, L ;
Zivanovic, MA .
NUCLEAR MEDICINE COMMUNICATIONS, 2005, 26 (08) :737-742