Strength and Surface Properties of a 3D-Printed Denture Base Polymer

被引:155
作者
Gad, Mohammed M. [1 ]
Fouda, Shaimaa M. [1 ]
Abualsaud, Reem [1 ]
Alshahrani, Faris A. [1 ]
Al-Thobity, Ahmad M. [1 ]
Khan, Soban Q. [2 ]
Akhtar, Sultan [3 ]
Ateeq, Ijlal Shahrukh [4 ]
Helal, Mohamed A. [5 ]
Al-Harbi, Fahad A. [1 ]
机构
[1] Imam Abdulrahman Bin Faisal Univ, Dept Substitut Dent Sci, Coll Dent, Dammam, Saudi Arabia
[2] Imam Abdulrahman Bin Faisal Univ, Dept Dent Educ, Coll Dent, Dammam, Saudi Arabia
[3] Imam Abdulrahman Bin Faisal Univ, Inst Res & Med Consultat IRMC, Dept Biophys, Dammam, Saudi Arabia
[4] Imam Abdulrahman Bin Faisal Univ, Dept Biomed Engn, Coll Engn, Dammam, Saudi Arabia
[5] Al Azhar Univ, Dept Removable Prosthodont, Fac Dent, Cairo, Egypt
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2022年 / 31卷 / 05期
关键词
3D printing; CAD; CAM; surface properties; mechanical test; polymethylmethacrylate; FABRICATING COMPLETE DENTURES; MECHANICAL-PROPERTIES; FLEXURAL STRENGTH; IMPACT STRENGTH; ACRYLIC RESIN; RESISTANCE; ROUGHNESS; DIRECTION;
D O I
10.1111/jopr.13413
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose This in vitro study evaluated the flexural strength, impact strength, hardness, and surface roughness of 3D-printed denture base resin subjected to thermal cycling treatment. Materials and Methods According to ISO 20795-1:2013 standards, 120 acrylic resin specimens (40/flexural strength test, 40/impact strength, and 40/surface roughness and hardness test, n = 10) were fabricated and distributed into two groups: heat-polymerized; (Major.Base.20) as control and 3D-printed (NextDent) as experimental group. Half of the specimens of each group were subjected to 10,000 thermal cycles of 5 to 55 degrees C simulating 1 year of clinical use. Flexural strength (MPa), impact strength (KJ/m(2)), hardness (VHN), and surface roughness (mu m) were measured using universal testing machine, Charpy's impact tester, Vickers hardness tester, and profilometer, respectively. Data were analyzed by ANOVA and Tukey honestly significant difference (HSD) test (alpha = 0.05). Results The values of flexural strength (MPa) were 86.63 +/- 1.0 and 69.15 +/- 0.88; impact strength (KJ/m(2))-6.32 +/- 0.50 and 2.44 +/- 0.31; hardness (VHN)-41.63 +/- 2.03 and 34.62 +/- 2.1; and surface roughness (mu m)-0.18 +/- 0.01 and 0.12 +/- 0.02 for heat-polymerized and 3D-printed denture base materials, respectively. Significant differences in all tested properties were recorded between heat-polymerized and 3D-printed denture base materials (P < 0.001). Thermal cycling significantly lowered the flexural strength (63.93 +/- 1.54 MPa), impact strength (2.40 +/- 0.35 KJ/m(2)), and hardness (30.17 +/- 1.38 VHN) of 3D-printed resin in comparison to thermal cycled heat-polymerized resin, but surface roughness showed non-significant difference (p = 0.262). Conclusion 3D-printed resin had inferior flexural strength, impact strength, and hardness values than heat-polymerized resin, but showed superior surface roughness. Temperature changes (thermal cycling) significantly reduced the hardness and flexural strength and increased surface roughness, but did not affect the impact strength.
引用
收藏
页码:412 / 418
页数:7
相关论文
共 42 条
[1]   High-impact strength acrylic denture base material processed by autoclave [J].
Abdulwahhab, Salwan Sami .
JOURNAL OF PROSTHODONTIC RESEARCH, 2013, 57 (04) :288-293
[2]   A Comparison of the Surface Properties of CAD/CAM and Conventional Polymethylmethacrylate (PMMA) [J].
Al-Dwairi, Ziad N. ;
Tahboub, Kawkab Y. ;
Baba, Nadim Z. ;
Goodacre, Charles J. ;
Ozcan, Mutlu .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (04) :452-457
[3]   Three-dimensional evaluation of marginal and internal fit of 3D-printed interim restorations fabricated on different finish line designs [J].
Alharbi, Nawal ;
Alharbi, Saud ;
Cuijpers, Vincent M. J. I. ;
Osmane, Reham B. ;
Wismeijer, Daniel .
JOURNAL OF PROSTHODONTIC RESEARCH, 2018, 62 (02) :218-226
[4]   Effects of build direction on the mechanical properties of 3D-printed complete coverage interim dental restorations [J].
Alharbi, Nawal ;
Osman, Reham ;
Wismeijer, Daniel .
JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (06) :760-767
[5]  
Alifui-Segbaya Frank, 2019, Compend Contin Educ Dent, V40, pe7
[6]   Comparison of Flexural Strength of Different CAD/CAM PMMA-Based Polymers [J].
Alp, Gulce ;
Murat, Sema ;
Yilmaz, Burak .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (02) :E491-E495
[7]  
[Anonymous], 2013, INT ORG STANDARDIZAT
[8]   Effects of thermal cycling on surface roughness, hardness and flexural strength of polymethylmethacrylate and polyamide denture base resins [J].
Ayaz, Elif Aydogan ;
Bagis, Bora ;
Turgut, Sedanur .
JOURNAL OF APPLIED BIOMATERIALS & FUNCTIONAL MATERIALS, 2015, 13 (03) :E280-E286
[9]   Prospective cohort pilot study of 2-visit CAD/CAM monolithic complete dentures and implant-retained overdentures: Clinical and patient-centered outcomes [J].
Bidra, Avinash S. ;
Farrell, Kimberly ;
Burnham, David ;
Dhingra, Ajay ;
Taylor, Thomas D. ;
Kuo, Chia-Ling .
JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (05) :578-586
[10]   COMPUTER-AIDED TECHNOLOGY FOR FABRICATING COMPLETE DENTURES: SYSTEMATIC REVIEW OF HISTORICAL BACKGROUND, CURRENT STATUS, AND FUTURE PERSPECTIVES [J].
Bidra, Avinash S. ;
Taylor, Thomas D. ;
Agar, John R. .
JOURNAL OF PROSTHETIC DENTISTRY, 2013, 109 (06) :361-366