Silylation with the Generation of a Fixed Charge for the Analysis of Alcohols by MALDI and SALDI Mass Spectrometry

被引:7
|
作者
Zhilyaev, D. I. [1 ]
Voskresensky, L. G. [1 ]
Polovkov, N. Yu. [2 ]
Borisov, R. S. [1 ,2 ]
机构
[1] Peoples Friendship Univ Russia, Moscow 117198, Russia
[2] Russian Acad Sci, Topchiev Inst Petrochem Synth, Moscow 119991, Russia
关键词
MALDI mass spectrometry; SALDI; alcohols; steroids; derivatization; fixed charge; DERIVATIZATION; PHENOLS;
D O I
10.1134/S1061934818140149
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new method of the derivatization of alcohols for their analysis by matrix-assisted laser desorption/ionization (MALDI) and surface-assisted laser desorption/ionization (SALDI) is proposed. The approach is based on the silylation of the analytes with bromomethylchlorodimethylsilane in the presence of tertiary amines to yield fixed-charge containing derivatives. The proposed method was tested using aliphatic alcohols, terpenols, and sterols. MALDI and SALDI mass spectra of all derivatives contain intense ion peaks corresponding to their cationic parts.
引用
收藏
页码:1323 / 1326
页数:4
相关论文
共 38 条
  • [31] Comparative analysis of the binding of thiacalix[4]arene-monocrown-ethers with monovalent metal salts using MALDI mass spectrometry
    D. R. Sharafutdinova
    O. B. Bazanova
    A. A. Murav’ev
    S. E. Solov’eva
    Z. A. Bredikhina
    V. M. Babaev
    I. S. Antipin
    Journal of Analytical Chemistry, 2016, 71 : 1352 - 1359
  • [32] Integration of microfiltration and anion-exchange nano particles-based magnetic separation with MALDI mass spectrometry for bacterial analysis
    Li, Shuping
    Guo, Zhongxian
    Liu, Ying
    Yang, Zhaoguang
    Hui, Hui Kim
    TALANTA, 2009, 80 (01) : 313 - 320
  • [33] Comparative analysis of the binding of thiacalix[4]arene-monocrown-ethers with monovalent metal salts using MALDI mass spectrometry
    Sharafutdinova, D. R.
    Bazanova, O. B.
    Murav'ev, A. A.
    Solov'eva, S. E.
    Bredikhina, Z. A.
    Babaev, V. M.
    Antipin, I. S.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 71 (14) : 1352 - 1359
  • [34] Estimation of measurement uncertainty for the quantitative analysis of pharmaceutical residues in river water using solid-phase extraction coupled with injector port silylation-gas chromatography-tandem mass spectrometry
    Satyanarayana, G. N. V.
    Du, Jun
    Asati, Ankita
    Pandey, Alok K.
    Kumar, Anupama
    Sharma, Manisha T.
    Mudiam, Mohana Krishna Reddy
    MICROCHEMICAL JOURNAL, 2020, 159
  • [35] Soft Ionization of Saturated Hydrocarbons, Alcohols and Nonpolar Compounds by Negative-Ion Direct Analysis in Real-Time Mass Spectrometry
    Cody, Robert B.
    Dane, A. John
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2013, 24 (03) : 329 - 334
  • [36] A green deep eutectic solvent based dispersive liquid-liquid microextraction for the quantitative analysis of 21 polychlorinated biphenyl metabolites in food of animal origin using injector port silylation-gas chromatography-tandem mass spectrometry
    Ganneru, Sireesha
    Seetha, Bala Subrahanyam
    Mudiam, Mohana Krishna Reddy
    JOURNAL OF CHROMATOGRAPHY A, 2023, 1708
  • [37] Derivatisation using m-(trifluoromethyl)phenyltrimethylammonium hydroxide of organic materials in artworks for analysis by gas chromatography-mass spectrometry:: Unusual reaction products with alcohols
    Sutherland, Ken
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1149 (01) : 30 - 37
  • [38] Characterization of N- and O-glycopeptides of recombinant human erythropoietins as potential biomarkers for doping analysis by means of microscale sample purification combined with MALDI-TOF and quadrupole IT/RTOF mass spectrometry
    Stübiger, G
    Marchetti, M
    Nagano, M
    Grimm, R
    Gmeiner, G
    Reichel, C
    Allmaier, G
    JOURNAL OF SEPARATION SCIENCE, 2005, 28 (14) : 1764 - 1778