Is Video-Oculography a Predictive Test for Myasthenia Gravis with Ocular Symptoms?

被引:2
|
作者
Sirin, Tuba Cerrahoglu [1 ,2 ,3 ]
Karaaslan, Zerrin [1 ,2 ]
Arkali, Burcu N. [1 ,2 ]
Bekdik, Pinar [4 ]
Akinci, Tuba [5 ]
Candan, Fatma [6 ]
Akarsu, Emel Oguz [1 ,2 ]
Baslo, M. Baris [1 ,2 ]
Orhan, Elif Kocasoy [1 ,2 ]
Oge, A. Emre [1 ,2 ]
机构
[1] Istanbul Univ, Dept Neurol, Istanbul Fac Med, Istanbul, Turkey
[2] Istanbul Univ, Dept Clin Neurophysiol, Istanbul Fac Med, Istanbul, Turkey
[3] Sisli Hamidiye Etfal Educ & Res Hosp, Dept Neurol, Istanbul, Turkey
[4] Kocaeli Derince Educ & Res Hosp, Dept Neurol, Istanbul, Turkey
[5] Beylikduzu State Hosp, Neurol Clin, Istanbul, Turkey
[6] Istanbul Medeniyet Univ, Goztepe Educ & Res Hosp, Dept Neurol, Istanbul, Turkey
关键词
Eye movements; myasthenia gravis; neuromuscular junction; ocular myasthenia; video-oculography; SINGLE-FIBER EMG; SACCADIC EYE-MOVEMENTS; EDROPHONIUM; DIAGNOSIS; ACCURACY; FATIGUE; MUSCLE;
D O I
10.4103/0028-3886.336330
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background and Objective: The aim of this study was to evaluate the contribution of extraocular muscle function testing with video-oculography (VOG), which is a noninvasive and easily applicable method of recording eye movement with digital cameras, to the diagnosis of myasthenia gravis (MG) in patients without any clinical eye movement abnormalities. Methods and Materials: The study included 18 patients prediagnosed with ocular MG: MG Group (N = 7) with abnormal, and non-MG Group (N = 11) with normal single-fiber electromyography. Control group included 50 healthy volunteers. Ocular movements were recorded with the EyeSeeCam VOG device. Results: The inward latency of the 10 degrees horizontal saccade and the downward latency of the 10 degrees vertical saccade were significantly delayed; and the downward amplitude of the 10 degrees vertical saccade was significantly lower in the MG group. Receiver operating characteristic curve analyses showed high specificity values for the discrimination of MG patients. Conclusions: This study supports the usefulness of the VOG device in revealing subclinical extraocular muscle involvement in MG.
引用
收藏
页码:80 / 86
页数:7
相关论文
共 50 条
  • [1] A video-oculography study of fixation instability in myasthenia gravis
    Le Nguyen, Elle Minh Ngoc
    Clough, Meaghan J.
    Fielding, Joanne
    White, Owen B.
    FRONTIERS IN NEUROLOGY, 2025, 16
  • [2] Ocular Myasthenia Gravis: A Diagnosis With Video Oculography
    de Verdal, Marie
    Renard, Dimitri
    Castelnovo, Giovanni
    JOURNAL OF NEURO-OPHTHALMOLOGY, 2025, 45 (01) : e18 - e19
  • [3] Quantifying the Vestibulo-Ocular Reflex with Video-Oculography: Nature and Frequency of Artifacts
    Mantokoudis, Georgios
    Tehrani, Ali S. Saber
    Kattah, Jorge C.
    Eibenberger, Karin
    Guede, Cynthia I.
    Zee, David S.
    Newman-Toker, David E.
    AUDIOLOGY AND NEURO-OTOLOGY, 2015, 20 (01) : 39 - 50
  • [4] Webcam-based system for video-oculography
    Naruniec, Jacek
    Wieczorek, Michal
    Szlufik, Stanislaw
    Koziorowski, Dariusz
    Tomaszewski, Michal
    Kowalski, Marek
    Przybyszewski, Andrzej
    IET COMPUTER VISION, 2017, 11 (02) : 173 - 180
  • [5] Ocular motor impairment in early-stage multiple sclerosis: a video-oculography assessment
    Ouattassi, Naouar
    El Ghoul, Salma El Alaoui
    Bouchal, Siham
    Belahssen, Mohammed Faouzi
    Ridal, Mohammed
    El Alami, Mohammed Nouredine El Amine
    EGYPTIAN JOURNAL OF OTOLARYNGOLOGY, 2023, 39 (01)
  • [6] Using video-oculography for galvanic evoked vestibulo-ocular monitoring in comatose patients
    Schlosser, HG
    Unterberg, A
    Clarke, A
    JOURNAL OF NEUROSCIENCE METHODS, 2005, 145 (1-2) : 127 - 131
  • [7] Video-oculography findings in patients with otosclerosis
    Kujala, J
    Aalto, H
    Hirvonen, TP
    OTOLOGY & NEUROTOLOGY, 2005, 26 (06) : 1134 - 1137
  • [8] Video-oculography as part of the ENG battery
    Eckert, AM
    Gizzi, M
    BRITISH JOURNAL OF AUDIOLOGY, 1998, 32 (06): : 411 - 416
  • [9] Simultaneous recordings of ocular microtremor and microsaccades with a piezoelectric sensor and a video-oculography system
    McCamy, Michael B.
    Collins, Niamh
    Otero-Millan, Jorge
    Al-Kalbani, Mohammed
    Macknik, Stephen L.
    Coakley, Davis
    Troncoso, Xoana G.
    Boyle, Gerard
    Narayanan, Vinodh
    Wolf, Thomas R.
    Martinez-Conde, Susana
    PEERJ, 2013, 1
  • [10] Controversies in Ocular Myasthenia Gravis
    Evoli, Amelia
    Iorio, Raffaele
    FRONTIERS IN NEUROLOGY, 2020, 11