Performance improvement of a hybrid air conditioning system using the indirect evaporative cooler with internal baffles as a pre-cooling unit

被引:31
|
作者
Kabeel, A. E. [1 ]
Abdelgaied, Mohamed [1 ]
Sathyamurthy, Ravishankar [2 ,3 ]
Arunkumar, T. [4 ]
机构
[1] Tanta Univ, Mech Power Engn Dept, Fac Engn, Tanta, Egypt
[2] SA Engn Coll, Ctr Excellence Energy & Nano Technol, Madras 600077, Tamil Nadu, India
[3] SA Engn Coll, Dept Mech Engn, Madras 600077, Tamil Nadu, India
[4] Anna Univ, Inst Energy Studies, Madras, Tamil Nadu, India
关键词
Desiccant material; Solar air collector; Evaporative cooler; Internal baffles; Air conditioning; DESICCANT COOLING SYSTEM; MATHEMATICAL-MODEL; WHEEL; DEHUMIDIFICATION; OPTIMIZATION; TEMPERATURE;
D O I
10.1016/j.aej.2017.04.005
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In the present paper, the effects of the indirect evaporative cooler with internal baffle on the performance of the hybrid air conditioning system are numerically investigated. The hybrid air conditioning system contains two indirect evaporative coolers with internal baffle, one is utilized to pre-cool the air inlet to the desiccant wheel and the other is utilized to pre-cool the supply air inlet to the room. The effects of the inlet conditions of the process and reactivation air and working air ratio on the thermal performance of the hybrid air conditioning system have been analyzed. The results of this study show that in the hybrid air conditioning system for using the indirect evaporative cooler with internal baffle as a pre-cooling unit, the supply air temperature reduced by 21% and the coefficient of performance improved by 71% as compared to previous designs of the hybrid air conditioning system at the same inlet conditions. For increasing process air inlet temperature from 25 degrees C to 45 degrees C, supply air temperature increases from 12.7 degrees C to 14.2 degrees C, thermal COP increases from 1.87 to 2.84, and supply air relative humidity increases from 76.7% to 77.4%. Also, for increasing the reactivation air inlet temperature from 70 degrees C to 110 degrees C, supply air temperature dropped from 15.9 degrees C to 10.9 degrees C, supply air relative humidity dropped from 82.7% to 71.8%, and thermal COP dropped from 4.5 to 1.7. The recommended optimal air working ratio in the indirect evaporative cooler with internal baffle should be 0.15. (C) 2017 Faculty of Engineering, Alexandria University. Production and hosting by Elsevier B.V.
引用
收藏
页码:395 / 403
页数:9
相关论文
共 40 条
  • [31] Optimisation of cooling performance and water consumption of a solid desiccant-assisted indirect evaporative cooling system using response surface methodology
    Lai, Lanbo
    Wang, Xiaolin
    Kefayati, Gholamreza
    Hu, Eric
    Ng, Kim Choon
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2024, 168 : 376 - 388
  • [32] Solid desiccant air conditioning system using desiccant dehumidifiers with cooling technique and thermal recovery unit: Experimental investigation and performance analysis
    Abdelgaied, Mohamed
    Saber, Mohamed A.
    Bassuoni, M. M.
    Khaira, Ahmad M.
    JOURNAL OF CLEANER PRODUCTION, 2023, 421
  • [33] Experimental study on the improvement of CO2 air conditioning system performance using an ejector
    Lee, Jae Seung
    Kim, Mo Se
    Kim, Min Soo
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (07): : 1614 - 1625
  • [34] Performance evaluation of absorption cooling system for air conditioning-based novel trigeneration system using solar energy
    Mishra, Shobhit
    Singh, Raj Kumar
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2024, 46 (06)
  • [35] Performance improvement in mobile air conditioning system using Al2O3/PAG nanolubricant
    Redhwan, A. A. M.
    Azmi, W. H.
    Sharif, M. Z.
    Mamat, R.
    Samykano, M.
    Najafi, G.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2019, 135 (02) : 1299 - 1310
  • [36] Performance improvement in mobile air conditioning system using Al2O3/PAG nanolubricant
    A. A. M. Redhwan
    W. H. Azmi
    M. Z. Sharif
    R. Mamat
    M. Samykano
    G. Najafi
    Journal of Thermal Analysis and Calorimetry, 2019, 135 : 1299 - 1310
  • [37] Characteristic Evaluation on the Cooling Performance of an Electrical Air Conditioning System Using R744 for a Fuel Cell Electric Vehicle
    Lee, Moo-Yeon
    Lee, Ho-Seong
    Won, Hong-Phil
    ENERGIES, 2012, 5 (05): : 1371 - 1383
  • [38] An insight into hybrid membrane-based air conditioning system performance using gray relational analysis methods: Structural versus operational parameters
    Hashemifard, Seyed Abdollatif
    Abdollahi, Farideh
    Khosravi, Arash
    Matsuura, Takeshi
    ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2022, 41 (06)
  • [39] Performance prediction of rotary solid desiccant dehumidifier in hybrid air-conditioning system using artificial neural network
    Jani, D. B.
    Mishra, Manish
    Sahoo, P. K.
    APPLIED THERMAL ENGINEERING, 2016, 98 : 1091 - 1103
  • [40] Effect of inter-cooling on the performance and economics of a solar energy assisted hybrid air conditioning system with six stages one-rotor desiccant wheel
    Elzahzby, Ali M.
    Kabeel, A. E.
    Bassuoni, M. M.
    Abdelgaied, Mohamed
    ENERGY CONVERSION AND MANAGEMENT, 2014, 78 : 882 - 896