Dynamic identification and model updating of an eight-storey CLT building

被引:61
作者
Aloisio, Angelo [1 ]
Pasca, Dag [2 ]
Tomasi, Roberto [2 ]
Fragiacomo, Massimo [1 ]
机构
[1] Univ Aquila, Dept Civil Construct Architectural & Environm Eng, Via G Gronchi 18, I-67100 Laquila, Abruszo, Italy
[2] Norwegian Univ Life Sci, Fac Sci & Technol, Oslo, Norway
关键词
Dynamic identification; Model updating; CLT buildings; Nonlinear response; OF-THE-ART; TIMBER; TESTS;
D O I
10.1016/j.engstruct.2020.110593
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
So far, few in situtests have been carried out to estimate the modal parameters of multi-storey Cross-Laminated-Timber (CLT) buildings: the understanding of their dynamic behaviour under operational conditions is still an open issue. In this paper, the results of the dynamic identification of an eight-storey CLT building are reported and interpreted in the light of a simplified shear-type analytical model. The structural model is calibrated on the experimental modal parameters, which are assessed using the Stochastic Subspace Identification (SSI). The SSI provides mode shapes, natural frequencies and damping factors of the structures in its first linear response range; The minimum of a modal-based objective function gives an estimation of the unknown parameters of the structural model. Given the results of the dynamic identification, the storey-masses are the chosen optimization parameters: the values of the experimental eigenfrequencies likely reveal a continuum-like behaviour of the building without connections. The identified storey masses are indeed realistic and confirm the negligible role of the connections in the low-amplitude dynamic response. The nonlinear effects of connections over the building response to higher displacements are discussed, providing simplified and practice-oriented correlations for the first natural frequency estimation.
引用
收藏
页数:8
相关论文
共 42 条
  • [1] A. S. of Civil Engineers, 2017, MIN DES LOADS ASS CR
  • [2] Allemang R.J., 1982, P 1 IMAC, P110
  • [3] The architrave a tasselli
    Aloisio, Angelo
    Alaggio, Rocco
    Fragiacomo, Massimo
    [J]. CASE STUDIES IN CONSTRUCTION MATERIALS, 2019, 11
  • [4] Sensitivity analysis of subspace-based damage indicators under changes in ambient excitation covariance, severity and location of damage
    Aloisio, Angelo
    Di Battista, Luca
    Alaggio, Rocco
    Fragiacomo, Massimo
    [J]. ENGINEERING STRUCTURES, 2020, 208
  • [5] Assessment of structural interventions using Bayesian updating and subspace-based fault detection methods: the case study of S. Maria di Collemaggio basilica, L'Aquila, Italy
    Aloisio, Angelo
    Di Battista, Luca
    Alaggio, Rocco
    Antonacci, Elena
    Fragiacomo, Massimo
    [J]. STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2021, 17 (02) : 141 - 155
  • [6] Extension of Generalized Bouc-Wen Hysteresis Modeling of Wood Joints and Structural Systems
    Aloisio, Angelo
    Alaggio, Rocco
    Kohler, Jochen
    Fragiacomo, Massimo
    [J]. JOURNAL OF ENGINEERING MECHANICS, 2020, 146 (03)
  • [7] Dynamic identification of a masonry facade from seismic response data based on an elementary Ordinary Least Squares approach
    Aloisio, Angelo
    Alaggio, Rocco
    Fragiacomo, Massimo
    [J]. ENGINEERING STRUCTURES, 2019, 197
  • [8] The 18th-Century Baraccato of L'Aquila
    Aloisio, Angelo
    Fragiacomo, Massimo
    D'Alo, Gianfranco
    [J]. INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE, 2020, 14 (06) : 870 - 884
  • [9] Traditional T-F Masonries in the City Centre of L'Aquila - The Baraccato Aquilano
    Aloisio, Angelo
    Fragiacomo, Massimo
    D'Alo, Gianfranco
    [J]. INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE, 2021, 15 (03) : 437 - 454
  • [10] Andersen P, 2011, STRUCT DYNAM-US, V3, P443