Systematic Review of Clinical Applications of CAD/CAM Technology for Craniofacial Implants Placement and Manufacturing of Orbital Prostheses

被引:14
作者
Tanveer, Waqas [1 ]
Ridwan-Pramana, Angela [2 ]
Molinero-Mourelle, Pedro [3 ]
Forouzanfar, Tymour [4 ]
机构
[1] Univ Amsterdam, Med Ctr, Dept Oral & Maxillofacial Surg, NL-1081 HV Amsterdam, Netherlands
[2] Stichting Bijzondere Tandheelkunde, Dept Maxillofacial Prosthodont, Ctr Special Care Dent, NL-1081 LA Amsterdam, Netherlands
[3] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, CH-3012 Bern, Switzerland
[4] Univ Amsterdam, Med Ctr, Oral Pathol & 3D Innovat Lab, Dept Oral & Maxillofacial Surg, NL-1081 HV Amsterdam, Netherlands
关键词
orbital prosthesis; digital planning; digital workflow; craniofacial implants; guided implants surgery; QUALITY-OF-LIFE; OSSEOINTEGRATED IMPLANTS; SURGICAL TEMPLATE; PLANNING SYSTEM; ACCURACY; REHABILITATION; DEFECTS; RECONSTRUCTION; FABRICATION; EXPERIENCE;
D O I
10.3390/ijerph182111349
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This systematic review was aimed at gathering technical and clinical applications of CAD/CAM technology for the preoperative planning of craniofacial implants placement, designing of molds and substructures and fabrication of orbital prostheses. Following the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines, an electronic search was executed. Human studies that utilized digital planning systems for the prosthetic rehabilitation of orbital defects were included. A total of 16 studies of 30 clinical cases, which were virtually planned through various digital planning and designing software, were included. The most common preoperative data required for digital planning were CT scans in 15 cases, the 3DSS-STD-II scanning system in 5 cases, an Artec Color 3D scanner in 3 cases and a NextEngine Desktop 3D laser scanner in 2 cases. Meanwhile, the digital designing software were Ease Orbital Implant Planning EOIPlan software in eight cases, Geomagic software in eight cases, Simplant software in four cases and Artec Studio 12 Professional in three cases. Surgical templates were fabricated for 12 cases to place 41 craniofacial implants in the orbital defect area. An image-guided surgical navigation system was utilized for the placement of five orbital implants in two cases. Digital designing and printing systems were reported for the preoperative planning of craniofacial implants placement, designing of molds and substructures and fabrication of orbital prostheses. The studies concluded that the digital planning, designing and fabrication of orbital prostheses reduce the clinical and laboratory times, reduces patient visits and provide a satisfactory outcome; however, technical skills and equipment costs are posing limitations on the use of these digital systems.
引用
收藏
页数:22
相关论文
共 58 条
  • [1] Outcome of extra-oral craniofacial endosseous implants
    Abu-Serriah, MM
    McGowan, DA
    Moos, KF
    Bagg, J
    [J]. BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2001, 39 (04) : 269 - 275
  • [2] The Modern and Digital Transformation of Oral Health Care: A Mini Review
    Alauddin, Muhammad Syafiq
    Baharuddin, Ahmad Syukran
    Ghazali, Mohd Ifwat Mohd
    [J]. HEALTHCARE, 2021, 9 (02)
  • [3] Assessment of health-related quality of life in Turkish patients with facial prostheses
    Atay, Arzu
    Peker, Kadriye
    Gunay, Yumushan
    Ebrinc, Servet
    Karayazgan, Banu
    Uysal, Omer
    [J]. HEALTH AND QUALITY OF LIFE OUTCOMES, 2013, 11
  • [4] Basten C H, 1995, Quintessence Int, V26, P609
  • [5] Bi YP, 2013, J PROSTHET DENT, V110, P424
  • [6] Implant Placement Is More Accurate Using Dynamic Navigation
    Block, Michael S.
    Emery, Robert W.
    Cullum, Daniel R.
    Sheikh, Ali
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2017, 75 (07) : 1377 - 1386
  • [7] Computer-aided design of facial prostheses by means of 3D-data acquisition and following symmetry analysis
    Bockey, Sophia
    Berssenbruegge, Philipp
    Dirksen, Dieter
    Wermker, Kai
    Klein, Martin
    Runte, Christoph
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2018, 46 (08) : 1320 - 1328
  • [8] Modern implant dentistry based on osseointegration: 50 years of progress, current trends and open questions
    Buser, Daniel
    Sennerby, Lars
    De Bruyn, Hugo
    [J]. PERIODONTOLOGY 2000, 2017, 73 (01) : 7 - 21
  • [9] Digital fabrication of orbital prosthesis mold using 3D photography and computer-aided design
    Chiu, Mimi
    Hong, Sheng Chiong
    Wilson, Graham
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 255 (02) : 425 - 426
  • [10] Analysis of errors in medical rapid prototyping models
    Choi, JY
    Choi, JH
    Kim, NK
    Kim, Y
    Lee, JK
    Kim, MK
    Lee, JH
    Kim, MJ
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2002, 31 (01) : 23 - 32