Monte Carlo calculated beam quality correction factors for two cylindrical ionization chambers in photon beams

被引:9
|
作者
Alissa, Mohamad [1 ]
Zink, Klemens [1 ,2 ,3 ]
Tessier, Frederic [4 ]
Schoenfeld, Andreas A. [5 ]
Czarnecki, Damian [1 ]
机构
[1] Univ Appl Sci Giessen THM, Inst Med Phys & Radiat Protect, Giessen, Germany
[2] Univ Med Ctr Giessen & Marburg, Dept Radiotherapy & Radiat Oncol, Marburg, Germany
[3] Marburg Ionbeam Therapyctr MIT, Marburg, Germany
[4] CNR, Ionizat Radiat Stand, Ottawa, ON, Canada
[5] Sun Nucl Corp, 3275 Suntree Blvd, Melbourne, FL 32940 USA
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2022年 / 94卷
关键词
Dosimetry; Beam quality correction factor; Ionization chamber; Monte Carlo simulation; MV photon beams; HIGH-ENERGY PHOTON; ELECTRON-TRANSPORT; SIMULATION; K(Q);
D O I
10.1016/j.ejmp.2021.12.012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Although several studies provide data for reference dosimetry, the SNC600c and SNC125c ionization chambers (Sun Nuclear Corporation, Melbourne, FL) are in clinical use worldwide for which no beam quality correction factors kQ are available. The goal of this study was to calculate beam quality correction factors kQ for these ionization chambers according to dosimetry protocols TG-51, TRS 398 and DIN 6800-2. Methods: Monte Carlo simulations using EGSnrc have been performed to calculate the absorbed dose to water and the dose to air within the active volume of ionization chamber models. Both spectra and simulations of beam transport through linear accelerator head models were used as radiation sources for the Monte Carlo calculations. Results: kQ values as a function of the respective beam quality specifier Q were fitted against recommended equations for photon beam dosimetry in the range of 4 MV to 25 MV. The fitting curves through the calculated values showed a root mean square deviation between 0.0010 and 0.0017. Conclusions: The investigated ionization chamber models (SNC600c, SNC125c) are not included in above mentioned dosimetry protocols, but are in clinical use worldwide. This study covered this knowledge gap and compared the calculated results with published kQ values for similar ionization chambers. Agreements with published data were observed in the 95% confidence interval, confirming the use of data for similar ionization chambers, when there are no kQ values available for a given ionization chamber.
引用
收藏
页码:17 / 23
页数:7
相关论文
共 50 条
  • [31] Monte Carlo calculations of correction factors for plastic phantoms in clinical photon and electron beam dosimetry
    Araki, Fujio
    Hanyu, Yuji
    Fukuoka, Miyoko
    Matsumoto, Kenji
    Okumura, Masahiko
    Oguchi, Hiroshi
    MEDICAL PHYSICS, 2009, 36 (07) : 2992 - 3001
  • [32] Spectral analysis of Monte Carlo calculated fluence correction and cema conversion factors for high- energy photon beams at different depths
    Roers, Julian
    Czarnecki, Damian
    Alissa, Mohamad
    Zink, Klemens
    FRONTIERS IN PHYSICS, 2023, 10
  • [33] Calculations of magnetic field correction factors for ionization chambers in a transverse magnetic field using Monte Carlo code TOPAS
    Mao, Lingli
    Pei, Xi
    Chao, Tsi-Chian
    Xu, Xie George
    RADIATION PHYSICS AND CHEMISTRY, 2021, 183
  • [34] Monte Carlo calculated correction factors for the NPL proton calorimeter
    Petrie, L. M.
    Galer, S.
    Shipley, D.
    Palmans, H.
    RADIATION PHYSICS AND CHEMISTRY, 2017, 140 : 383 - 385
  • [35] Photon beam quality correction factors for the NE2571A and NE2581A thimble ionization chambers using PENELOPE
    Erazo, Fabian
    Lallena, Antonio M.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (01): : 232 - 236
  • [36] Investigations on the beam quality correction factor for ionization chambers in high-energy brachytherapy dosimetry
    Failing, T.
    Hensley, F. W.
    Keil, B.
    Zink, K.
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (16)
  • [37] Determination of recombination and polarity correction factors, kS and kP, for small cylindrical ionization chambers PTW 31021 and PTW 31022 in pulsed filtered and unfiltered beams
    Bruggmoser, Gregor
    Saum, Rainer
    Kranzer, Rafael
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2018, 28 (03): : 247 - 253
  • [38] Monte Carlo calculated and experimentally determined output correction factors for small field detectors in Leksell Gamma Knife Perfexion beams
    Benmakhlouf, H.
    Johansson, J.
    Paddick, I.
    Andreo, P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (10) : 3959 - 3973
  • [39] On Monte Carlo modeling of megavoltage photon beams: A revisited study on the sensitivity of beam parameters
    Chibani, Omar
    Moftah, Belal
    Ma, C. -M. Charlie
    MEDICAL PHYSICS, 2011, 38 (01) : 188 - 201
  • [40] Monte Carlo and water calorimetric determination of kilovoltage beam radiotherapy ionization chamber correction factors
    Bancheri, Julien
    Ketelhut, Steffen
    Buermann, Ludwig
    Seuntjens, Jan
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (10)