Monte Carlo calculated beam quality correction factors for two cylindrical ionization chambers in photon beams

被引:9
|
作者
Alissa, Mohamad [1 ]
Zink, Klemens [1 ,2 ,3 ]
Tessier, Frederic [4 ]
Schoenfeld, Andreas A. [5 ]
Czarnecki, Damian [1 ]
机构
[1] Univ Appl Sci Giessen THM, Inst Med Phys & Radiat Protect, Giessen, Germany
[2] Univ Med Ctr Giessen & Marburg, Dept Radiotherapy & Radiat Oncol, Marburg, Germany
[3] Marburg Ionbeam Therapyctr MIT, Marburg, Germany
[4] CNR, Ionizat Radiat Stand, Ottawa, ON, Canada
[5] Sun Nucl Corp, 3275 Suntree Blvd, Melbourne, FL 32940 USA
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2022年 / 94卷
关键词
Dosimetry; Beam quality correction factor; Ionization chamber; Monte Carlo simulation; MV photon beams; HIGH-ENERGY PHOTON; ELECTRON-TRANSPORT; SIMULATION; K(Q);
D O I
10.1016/j.ejmp.2021.12.012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Although several studies provide data for reference dosimetry, the SNC600c and SNC125c ionization chambers (Sun Nuclear Corporation, Melbourne, FL) are in clinical use worldwide for which no beam quality correction factors kQ are available. The goal of this study was to calculate beam quality correction factors kQ for these ionization chambers according to dosimetry protocols TG-51, TRS 398 and DIN 6800-2. Methods: Monte Carlo simulations using EGSnrc have been performed to calculate the absorbed dose to water and the dose to air within the active volume of ionization chamber models. Both spectra and simulations of beam transport through linear accelerator head models were used as radiation sources for the Monte Carlo calculations. Results: kQ values as a function of the respective beam quality specifier Q were fitted against recommended equations for photon beam dosimetry in the range of 4 MV to 25 MV. The fitting curves through the calculated values showed a root mean square deviation between 0.0010 and 0.0017. Conclusions: The investigated ionization chamber models (SNC600c, SNC125c) are not included in above mentioned dosimetry protocols, but are in clinical use worldwide. This study covered this knowledge gap and compared the calculated results with published kQ values for similar ionization chambers. Agreements with published data were observed in the 95% confidence interval, confirming the use of data for similar ionization chambers, when there are no kQ values available for a given ionization chamber.
引用
收藏
页码:17 / 23
页数:7
相关论文
共 50 条
  • [21] Monte Carlo calculation of the photon beam quality correction factor kQ, Q0 for ionization chambers of very small volume: Use of variance reduction techniques driven with an ant colony algorithm
    Garvi, A. M.
    Zamora, L. I.
    Anguiano, M.
    Lallena, A. M.
    Garcia-Pareja, S.
    RADIATION PHYSICS AND CHEMISTRY, 2024, 225
  • [22] Monte Carlo-derived ionization chamber correction factors in therapeutic carbon ion beams
    Khan, Ahtesham Ullah
    Simiele, Eric A.
    DeWerd, Larry A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (19)
  • [23] Electron beam quality kQ,Q0 factors for various ionization chambers: a Monte Carlo investigation with PENELOPE
    Erazo, F.
    Brualla, L.
    Lallena, A. M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (21) : 6673 - 6691
  • [24] Monte Carlo calculation of perturbation correction factors for air-filled ionization chambers in clinical proton beams using TOPAS/GEANT
    Baumann, Kilian-Simon
    Kaupa, Sina
    Bach, Constantin
    Engenhart-Cabillic, Rita
    Zink, Klemens
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2021, 31 (02): : 175 - 191
  • [25] Monte Carlo simulation of initial and volume ion recombination correction factor in plane parallel ionization chambers exposed to ion beams
    Orts, Marina
    Rossomme, Severine
    Souris, Kevin
    Sterpin, Edmond
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (16)
  • [26] The determination of beam quality correction factors: Monte Carlo simulations and measurements
    Gonzalez-Castano, D. M.
    Hartmann, G. H.
    Sanchez-Doblado, F.
    Gomez, F.
    Kapsch, R-P
    Pena, J.
    Capote, R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (15) : 4723 - 4741
  • [27] Polarity correction factor for flattening filter free photon beams in several cylindrical ionization chambers
    Ogata T.
    Uehara K.
    Nakayama M.
    Tsudou S.
    Masutani T.
    Okayama T.
    Radiological Physics and Technology, 2016, 9 (2) : 187 - 192
  • [28] Output correction factors for small static fields in megavoltage photon beams for seven ionization chambers in two orientations - perpendicular and parallel
    Casar, Bozidar
    Gershkevitsh, Eduard
    Mendez, Ignasi
    Jurkovic, Slaven
    Huq, M. Saiful
    MEDICAL PHYSICS, 2020, 47 (01) : 242 - 259
  • [29] Assessment of ionization chamber correction factors in photon beams using a time saving strategy with PENELOPE code
    Reis, C. Q. M.
    Nicolucci, P.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (02): : 297 - 304
  • [30] Experimental determination of k Q factors for two types of ionization chambers in scanned proton beams
    Medin, Joakim
    Andreo, Pedro
    Palmans, Hugo
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (05)