High-pitch dual-source CT angiography of the aortic valve-aortic root complex without ECG-synchronization

被引:57
作者
Karlo, Christoph [1 ]
Leschka, Sebastian [1 ]
Goetti, Robert Paul [1 ]
Feuchtner, Gudrun [1 ]
Desbiolles, Lotus [1 ]
Stolzmann, Paul [1 ]
Plass, Andre [2 ]
Falk, Volkmar [2 ]
Marincek, Borut [1 ]
Alkadhi, Hatem [1 ,3 ,4 ]
Baumueller, Stephan [1 ]
机构
[1] Univ Zurich Hosp, Inst Diagnost & Intervent Radiol, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Cardiovasc Surg Clin, CH-8091 Zurich, Switzerland
[3] Massachusetts Gen Hosp, Cardiac MR PET CT Grp, Boston, MA 02114 USA
[4] Harvard Univ, Sch Med, Boston, MA USA
关键词
Dual-source computed tomography; DSCT; High pitch; Radiation dose; Aortic valve; COMPUTED-TOMOGRAPHY; CORONARY-ANGIOGRAPHY; THORACIC AORTA; CHEST-PAIN; REDUCTION; EXPOSURE;
D O I
10.1007/s00330-010-1907-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare image quality and radiation dose of high-pitch computed tomography angiography(CTA) of the aortic valve-aortic root complex with and without prospective ECG-gating compared to a retrospectively ECG-gated standard-pitch acquisition. 120 patients(mean age 68 +/- 13 years) were examined using a 128-slice dual-source CT system using prospectively ECG-gated high-pitch(group A; n = 40), non-ECG-gated high-pitch(group B; n = 40) or retrospectively ECG-gated standard-pitch(C; n = 40) acquisition techniques. Image quality of the aortic root, valve and ascending aorta including the coronary ostia was assessed by two independent readers. Image noise was measured, radiation dose estimates were calculated. Interobserver agreement was good(kappa = 0.64-0.78). Image quality was diagnostic in 38/40 patients(group A), 37/40(B) and 38/40(C) with no significant difference in number of patients with diagnostic image quality among all groups (p = 0.56). Significantly more patients showed excellent image quality in group A compared to groups B and C(each, p < 0.01). Average image noise was significantly different between all groups(p < 0.05). Mean radiation dose estimates in groups A and B(each; 2.4 +/- 0.3 mSv) were significantly lower compared to group C(17.5 +/- 4.4 mSv; p < 0.01). High-pitch dual-source CTA provides diagnostic image quality of the aortic valve-aortic root complex even without ECG-gating at 86% less radiation dose when compared to a standard-pitch ECG-gated acquisition.
引用
收藏
页码:205 / 212
页数:8
相关论文
共 22 条
[1]   Influence of slice thickness and reconstruction kernel on the computed tomographic attenuation of coronary atherosclerotic plaque [J].
Achenbach, Stephan ;
Boehmer, Kerstin ;
Pflederer, Tobias ;
Ropers, Dieter ;
Seltmann, Martin ;
Lell, Michael ;
Anders, Katharina ;
Kuettner, Axel ;
Uder, Michael ;
Daniel, Werner G. ;
Marwan, Mohamed .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2010, 4 (02) :110-115
[2]   Arm Raising at Exposure-controlled Multidetector Trauma CT of Thoracoabdominal Region: Higher Image Quality, Lower Radiation Dose [J].
Brink, Monique ;
de lange, Frank ;
Oostveen, Luuk J. ;
Dekker, Helena M. ;
Kool, Digna R. ;
Deunk, Jaap ;
Edwards, Michael J. R. ;
van Kuijk, Cornelis ;
Kamman, Richard L. ;
Blickman, Johan G. .
RADIOLOGY, 2008, 249 (02) :661-670
[3]   Triple rule-out CT in the emergency department: protocols and spectrum of imaging findings [J].
Frauenfelder, Thomas ;
Appenzeller, Philippe ;
Karlo, Christoph ;
Scheffel, Hans ;
Desbiolles, Lotus ;
Stolzmann, Paul ;
Marincek, Borut ;
Alkadhi, Hatem ;
Schertler, Thomas .
EUROPEAN RADIOLOGY, 2009, 19 (04) :789-799
[4]   Low Dose High-Pitch Spiral Acquisition 128-Slice Dual-Source Computed Tomography for the Evaluation of Coronary Artery Bypass Graft Patency [J].
Goetti, Robert ;
Leschka, Sebastian ;
Baumueller, Stephan ;
Plass, Andre ;
Wieser, Monika ;
Desbiolles, Lotus ;
Stolzmann, Paul ;
Falk, Volkmar ;
Marincek, Borut ;
Alkadhi, Hatem ;
Feuchtner, Gudrun .
INVESTIGATIVE RADIOLOGY, 2010, 45 (06) :324-330
[5]   High-Pitch Dual-Source CT Angiography of the Thoracic and Abdominal Aorta: Is Simultaneous Coronary Artery Assessment Possible? [J].
Goetti, Robert ;
Baumueller, Stephan ;
Feuchtner, Gudrun ;
Stolzmann, Paul ;
Karlo, Christoph ;
Alkadhi, Hatem ;
Leschka, Sebastian .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (04) :938-944
[6]  
Huda Walter, 2007, Proc Am Thorac Soc, V4, P316, DOI 10.1513/pats.200611-172HT
[7]   Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation [J].
Jakobs, TF ;
Becker, CR ;
Ohnesorge, B ;
Flohr, T ;
Suess, C ;
Schoepf, UJ ;
Reiser, MF .
EUROPEAN RADIOLOGY, 2002, 12 (05) :1081-1086
[8]   Dual-source CT for chest pain assessment [J].
Johnson, Thorsten R. C. ;
Nikolaou, Konstantin ;
Becker, Alexander ;
Leber, Alexander W. ;
Rist, Carsten ;
Wintersperger, Bernd J. ;
Reiser, Maximilian F. ;
Becker, Christoph R. .
EUROPEAN RADIOLOGY, 2008, 18 (04) :773-780
[9]   High-Pitch Electrocardiogram-Triggered Computed Tomography of the Chest Initial Results [J].
Lell, Michael ;
Hinkmann, Fabian ;
Anders, Katharina ;
Deak, Paul ;
Kalender, Willi A. ;
Uder, Michael ;
Achenbach, Stephan .
INVESTIGATIVE RADIOLOGY, 2009, 44 (11) :728-733
[10]   Prospectively ECG-triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: technique and initial experience [J].
Lell, Michael ;
Marwan, Mohamed ;
Schepis, Tiziano ;
Pflederer, Tobias ;
Anders, Katharina ;
Flohr, Thomas ;
Allmendinger, Thomas ;
Kalender, Willi ;
Ertel, Dirk ;
Thierfelder, Carsten ;
Kuettner, Axel ;
Ropers, Dieter ;
Daniel, Werner G. ;
Achenbach, Stephan .
EUROPEAN RADIOLOGY, 2009, 19 (11) :2576-2583