Determination of organochlorine pesticides and polychlorinated biphenyls in post-mortem human lung by matrix solid-phase dispersion with the aid of response surface methodology and desirability function

被引:45
作者
Rallis, Georgios N. [1 ]
Sakkas, Vasilios A. [1 ]
Boumba, Vassiliki A. [2 ]
Vougiouklakis, Theodore [2 ]
Albanis, Triantafyllos A. [1 ]
机构
[1] Univ Ioannina, Dept Chem, Analyt Chem Lab, GR-45110 Ioannina, Greece
[2] Univ Ioannina, Sch Med, Dept Forens Med & Toxicol, GR-45110 Ioannina, Greece
关键词
Matrix solid-phase dispersion; Organochlorine pesticides; Polychlorinated biphenyls; Post-mortem human lung; Experimental design; Desirability profile; PERFORMANCE LIQUID-CHROMATOGRAPHY; GAS-CHROMATOGRAPHY; BIOTA SAMPLES; EXTRACTION; RESIDUES; MICROEXTRACTION; OPTIMIZATION; POLLUTANTS; EXPOSURE; TISSUES;
D O I
10.1016/j.chroma.2011.12.083
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A matrix solid-phase dispersion (MSPD) method for the simultaneous determination of 20 organochlorine pesticides (OCPs) (aldrin, endrin, dieldrin, alpha-BHC, beta-BHC, gamma-BHC, delta-BHC, alpha-chlordane, gamma-chlordane, p.p'-DDE, p.p'-DDT, p.p'-DDD, endosulfan I, endosulfan II, endosulfan sulfate, endrin aldehyde, heptachlor, heptachlor epoxide, endrin ketone and methoxychlor) and six polychlorinated biphenyl (PCB) congeners (PCB 28, 52, 101, 138, 153 and 180) in post-mortem human lung has been developed and validated. Response surface methodology (RSM) and desirability function were employed to optimize the extraction conditions of MSPD. Extraction was carried out using Florisil (2.0 g) as the sorbent material as well as clean-up adsorbent (1.5401 g), n-hexane:dichloromethane (11:89, v/v) as the eluting solvent (15.45 mL) and Na2SO4 (2.0 g) as dehydrating agent. Determination and quantification of OCPs and PCBs residues were carried out using a gas chromatograph equipped with an electron capture detector (GC-ECD). A mass spectrometric detector (GC-MS) in the selected ion monitoring (SIM) mode was also used for confirmation purposes. Method detection limits by GC-MS ranged from 0.42 to 0.87 ngg(-1) and 0.51 to 1.35 ngg(-1), for OCPs and PCBs, respectively. Lower detection limits were calculated for GC-ECD ranging between 0.15-0.30 ngg(-1) and 0.18-0.48 ngg(-1), respectively. Relative standard deviations did not exceed 9%. Analytes provided recoveries ranging from 65% to 106%. The proposed method was successfully applied to the analysis of lung tissues from six autopsy cases. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 46 条
[1]   ORGANOCHLORINE COMPOUNDS AND ESTROGEN-RELATED CANCERS IN WOMEN [J].
ADAMI, HO ;
LIPWORTH, L ;
TITUSERNSTOFF, L ;
HSIEH, CC ;
HANBERG, A ;
AHLBORG, U ;
BARON, J ;
TRICHOPOULOS, D .
CANCER CAUSES & CONTROL, 1995, 6 (06) :551-566
[2]   Determination of organophosphorus pesticides in fruit juices by matrix solid-phase dispersion and gas chromatography [J].
Albero, B ;
Sánchez-Brunete, C ;
Tadeo, JL .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2003, 51 (24) :6915-6921
[3]  
[Anonymous], 2003, END PREL DOSS, P55
[4]  
[Anonymous], STOCKH CONV PERS ORG
[5]  
[Anonymous], TOXNET
[6]   Applications of matrix solid-phase dispersion in food analysis [J].
Barker, Steven A. .
Journal of Chromatography A, 2000, 880 (01) :63-68
[7]   Matrix solid-phase dispersion [J].
Barker, SA .
JOURNAL OF CHROMATOGRAPHY A, 2000, 885 (1-2) :115-127
[8]   Distribution of persistent organochlorine pollutants in maternal and foetal tissues: Data from an Italian polluted urban area [J].
Bergonzi, Roberto ;
Specchia, Cristina ;
Dinolfo, Mariadaniela ;
Tomasi, Cesare ;
De Palma, Giuseppe ;
Frusca, Tiziana ;
Apostoli, Pietro .
CHEMOSPHERE, 2009, 76 (06) :747-754
[9]   Application of matrix solid-phase dispersion methodology to the extraction of endogenous peptides from porcine hypothalamus samples for MS and LC-MS analysis [J].
Cai, Xiaoming ;
Wang, Chaoran ;
Xu, Junyan ;
Xue, Xingya ;
Zhang, Xiuli ;
Liang, Xinmiao .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (9-10) :657-661
[10]   Analysis of pesticide residues in matrices with high lipid contents by membrane separation coupled on-line to a high-performance liquid chromatography system [J].
Carabias-Martínez, R ;
Rodríguez-Gonzalo, E ;
Paniagua-Marcos, PH ;
Hernández-Méndez, J .
JOURNAL OF CHROMATOGRAPHY A, 2000, 869 (1-2) :427-439