An untethered cable-driven ankle exoskeleton with plantarflexion-dorsiflexion bidirectional movement assistance

被引:24
作者
Wang, Tian-miao [1 ]
Pei, Xuan [1 ]
Hou, Tao-gang [1 ,2 ]
Fan, Yu-bo [3 ,5 ]
Yang, Xuan [1 ]
Herr, Hugh M. [4 ]
Yang, Xing-bang [4 ]
机构
[1] Beihang Univ, Sch Mech Engn & Automat, Beijing 100083, Peoples R China
[2] Beihang Univ, Shenyuan Honors Coll, Beijing 100083, Peoples R China
[3] Beihang Univ, Sch Biol Sci & Med Engn, Beijing 100083, Peoples R China
[4] MIT, Media Lab, Cambridge, MA 02139 USA
[5] Beihang Univ, Beijing Adv Innovat Ctr Biomed Engn, Beijing 100083, Peoples R China
基金
中国国家自然科学基金;
关键词
Ankle exoskeleton; Plantarflexion-dorsiflexion bidirectional assistance; Biological gait torque; Cable-driven; Gait detection; TP242; 6; WALKING; GAIT; BIOMECHANICS; ENERGETICS; ORTHOSIS; VELOCITY; DESIGN;
D O I
10.1631/FITEE.1900455
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Lower-limb assisted exoskeletons are widely researched for movement assistance or rehabilitation training. Due to advantages of compliance with human body and lightweight, some cable-driven prototypes have been developed, but most of these can assist only unidirectional movement. In this paper we present an untethered cable-driven ankle exoskeleton that can achieve plantarflexion-dorsiflexion bidirectional motion bilaterally using a pair of single motors. The main weights of the exoskeleton, i.e., the motors, power supplement units, and control units, were placed close to the proximity of the human body, i.e., the waist, to reduce the redundant rotation inertia which would apply on the wearer's leg. A cable force transmission system based on gear-pulley assemblies was designed to transfer the power from the motor to the end-effector effectively. A cable self-tension device on the power output unit was designed to tension the cable during walking. The gait detection system based on a foot pressure sensor and an inertial measurement unit (IMU) could identify the gait cycle and gait states efficiently. To validate the power output performance of the exoskeleton, a torque tracking experiment was conducted. When the subject was wearing the exoskeleton with power on, the muscle activity of the soleus was reduced by 5.2% compared to the state without wearing the exoskeleton. This preliminarily verifies the positive assistance effect of our exoskeleton. The study in this paper demonstrates the promising application of a lightweight cable-driven exoskeleton on human motion augmentation or rehabilitation.
引用
收藏
页码:723 / 739
页数:17
相关论文
共 41 条
[1]  
[Anonymous], 2009, BIOMECHANICS MOTOR C
[2]   Stronger, Smarter, Softer Next-Generation Wearable Robots [J].
Asbeck, Alan T. ;
De Rossi, Stefano M. M. ;
Galiana, Ignacio ;
Ding, Ye ;
Walsh, Conor J. .
IEEE ROBOTICS & AUTOMATION MAGAZINE, 2014, 21 (04) :22-33
[3]   A soft robotic exosuit improves walking in patients after stroke [J].
Awad, Louis N. ;
Bae, Jaehyun ;
O'Donnell, Kathleen ;
De Rossi, Stefano M. M. ;
Hendron, Kathryn ;
Sloot, Lizeth H. ;
Kudzia, Pawel ;
Allen, Stephen ;
Holt, Kenneth G. ;
Ellis, Terry D. ;
Walsh, Conor J. .
SCIENCE TRANSLATIONAL MEDICINE, 2017, 9 (400)
[4]  
Bai Y., 2015, The Open Mechanical Engineering Journal, V9, P982, DOI [10.2174/1874155x01509010982, DOI 10.2174/1874155X01509010982]
[5]   The effects of adding mass to the legs on the energetics and biomechanics of walking [J].
Browning, Raymond C. ;
Modica, Jesse R. ;
Kram, Rodger ;
Goswami, Ambarish .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2007, 39 (03) :515-525
[6]   Running With an Elastic Lower Limb Exoskeleton [J].
Cherry, Michael S. ;
Kota, Sridhar ;
Young, Aaron ;
Ferris, Daniel P. .
JOURNAL OF APPLIED BIOMECHANICS, 2016, 32 (03) :269-277
[7]  
Chu A, 2005, IEEE INT CONF ROBOT, P4345
[8]   Reducing the energy cost of human walking using an unpowered exoskeleton [J].
Collins, Steven H. ;
Wiggin, M. Bruce ;
Sawicki, Gregory S. .
NATURE, 2015, 522 (7555) :212-+
[9]  
Diller S, 2016, IEEE INT CONF ROBOT, P682, DOI 10.1109/ICRA.2016.7487194
[10]   Artificial muscles for wearable assistance and rehabilitation [J].
Dong, Tian-yun ;
Zhang, Xiang-liang ;
Liu, Tao .
FRONTIERS OF INFORMATION TECHNOLOGY & ELECTRONIC ENGINEERING, 2018, 19 (11) :1303-1315