The influence of breast skin thickness variation with aging on the mammographic X-ray spectra: A Monte Carlo study

被引:0
作者
Zadehrafi, M. [1 ]
机构
[1] Horia Hulubei Natl Inst Res & Dev Phys & Nucl Eng, 30 Reactorului St,POB MG 6, RO-077125 Bucharest, Romania
来源
INTERNATIONAL JOURNAL OF RADIATION RESEARCH | 2021年 / 19卷 / 04期
关键词
X-ray; mammography; breast skin; attenuation coefficients; transmission factor; Monte Carlo; MCNP; IMAGE QUALITY; DIGITAL MAMMOGRAPHY; RADIATION;
D O I
10.29242/ijrr.19.4.971
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: To approach the mammographic X-ray investigations in a metrological manner, any potential improvement needs to be considered. In this study, the influence of skin thickness variation on the mammographic Xray spectra was investigated. Additionally, some attenuation parameters such as linear and mass attenuation coefficients, mean free path, and half-value layer thickness were assessed for exposure of the skin to the mammographic X-rays. Materials and Methods: A theoretical experiment was performed using MCNP6.2 by simulation of two collimators, a detection area, a skin sample, and a point monoenergetic X-ray source. Carrying out this experiment, the above-mentioned parameters were estimated. As a validation process, the mass attenuation coefficients obtained by MCNP were compared with the results of XCOM. Results: The good agreement between the results of MCNP and XCOM reveals that the geometrical setup was modeled correctly by MCNP. It also implies the reliability of the Monte Carlo technique for attenuation calculations of low-energy X-rays through the skin. Upon increasing the breast skin thickness, its transmission factor against mammographic X-rays decreases linearly, and it increases by increasing the photon energy. The older the patient, the more transmission factor of the breast skin against the low energy X-ray. Conclusion: Increasing the X-ray energy leads to less sensitivity of the transmission factor to the skin thickness. Thus, to have the best possible quality of X-ray mammography images, the patient's age may also be considered as well as the other factors, when selecting the proper energies and for fine-tuning the used X-ray generators.
引用
收藏
页码:971 / 978
页数:8
相关论文
共 27 条
[1]  
[Anonymous], 2014, J APPL COMPUTAT MATH
[3]   Gamma Ray Shielding Study of BariumeBismutheBorosilicate Glasses as Transparent Shielding Materials using MCNP-4C Code, XCOM Program, and Available Experimental Data [J].
Bagheri, Reza ;
Moghaddam, Alireza Khorrami ;
Yousefnia, Hassan .
NUCLEAR ENGINEERING AND TECHNOLOGY, 2017, 49 (01) :216-223
[4]  
Berger M. J., 2010, PHOTON CROSS SECTION
[5]   Effect of aging on breast skin thickness and elasticity: implications for breast support [J].
Coltman, C. E. ;
Steele, J. R. ;
McGhee, D. E. .
SKIN RESEARCH AND TECHNOLOGY, 2017, 23 (03) :303-311
[6]   Optimization of x-ray spectra in digital mammography through Monte Carlo simulations [J].
Cunha, D. M. ;
Tomal, A. ;
Poletti, M. E. .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (07) :1919-1935
[7]   Determination of mass attenuation coefficient of low-Z dosimetric materials [J].
El-Khayatt, A. M. ;
Ali, A. M. ;
Singh, Vishwanath P. ;
Badiger, N. M. .
RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2014, 169 (12) :1038-1044
[8]   A comprehensive study for mass attenuation coefficients of different parts of the human body through Monte Carlo methods [J].
Ermis, E. E. ;
Pilicer, F. B. ;
Pilicer, E. ;
Celiktas, C. .
NUCLEAR SCIENCE AND TECHNIQUES, 2016, 27 (03)
[9]   Dose and diagnostic performance comparison between phase-contrast mammography with synchrotron radiation and digital mammography: a clinical study report [J].
Fedon, Christian ;
Rigon, Luigi ;
Arfelli, Fulvia ;
Dreossi, Diego ;
Quai, Elisa ;
Tonutti, Maura ;
Tromba, Giuliana ;
Cova, Maria Assunta ;
Longo, Renata .
JOURNAL OF MEDICAL IMAGING, 2018, 5 (01)
[10]  
Gennaro G, 2017, HDB XRAY IMAGING, V457