Iridium oxide sensors for acidity and basicity detection in industrial lubricants

被引:53
作者
Smiechowski, MF
Lvovich, VF [1 ]
机构
[1] Lubrizol Corp, Wickliffe, OH 44092 USA
[2] Case Western Reserve Univ, Dept Chem Engn, Cleveland, OH 44106 USA
关键词
iridium oxide; potentiometry; acidity; lubricant; non-aqueous system;
D O I
10.1016/S0925-4005(03)00542-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The lubrication and automotive industries are seeking on-line sensors capable of determining the chemical condition and degree of degradation of industrial and automotive lubricants in order to signal the need for an oil change. Levels of acidity and basicity in non-aqueous media are parameters common to a wide variety of industrial fluids and closely related to rate of the lubricant oxidation breakdown. Therefore, development of chemcical devices capable of continuous monitoring of these parameters remains an important goal of industrial sensor research. Chronopotentiometric (CP) sensors based on solid-state reversible oxide films of iridium demonstrate a number of advantages for detection of acidity and basicity levels in non-aqueous industrial lubricants over other types of acidity sensors, such as glass electrode and ion-selective field effect transistors. Iridium, oxide sensors fabricated by different methods and having various geometric configurations (macro-scale versus microelectromechanical systems (MEMS)) were compared. The sensors demonstrated linear responses to changes in oil acidity and basicity that were in agreement with proposed electrochemical mechanisms. Studies of long term stability and durability of the metal oxide sensors in the oil solutions illustrated that improvement to the sensor fabrication process is needed. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:261 / 267
页数:7
相关论文
共 22 条
[1]  
BARD AJ, 2001, ELECTROCHEMICAL METH, P555
[2]   Irreversible decrease of Ir oxide film redox kinetics [J].
Bock, C ;
Birss, VI .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1999, 146 (05) :1766-1772
[3]   OXIDATION OF FORMIC-ACID ON NOBLE-METAL ELECTRODES .2. COMPARISON OF BEHAVIOR OF PURE ELECTRODES [J].
CAPON, A ;
PARSONS, R .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1973, 44 (02) :239-254
[4]  
CIPRIS D, 1990, P EL SOC SER SENS MO, V87, P401
[5]  
Dybko A., 2001, Sensors, V1, P29, DOI [DOI 10.3390/S10100029, 10.3390/s10100029]
[6]   Monitoring of engine oil degradation by voltammetric methods utilizing disposable solid wire microelectrodes [J].
Farrington, AM ;
Slater, JM .
ANALYST, 1997, 122 (06) :593-596
[7]   ELECTRONIC SEMICONDUCTING OXIDES AS PH SENSORS [J].
FOG, A ;
BUCK, RP .
SENSORS AND ACTUATORS, 1984, 5 (02) :137-146
[8]  
Galster H., 1991, PH MEASUREMENTS FUND
[9]   PALLADIUM-PALLADIUM OXIDE PH ELECTRODES [J].
GRUBB, WT ;
KING, LH .
ANALYTICAL CHEMISTRY, 1980, 52 (02) :270-273
[10]   Response of an iridium oxide pH-sensor in nonaqueous solutions. Comparison with other pH-sensors [J].
Izutsu, K ;
Yamamoto, H .
ANALYTICAL SCIENCES, 1996, 12 (06) :905-909