PhosphoMolybdic Acid and Poly(Paraphenylenediamine) Modified Carbon Paste Electrode using Voltammetric Determination of Dopamine and Uric Acid

被引:0
作者
Lakshmi, Gundluru Bhagya [1 ]
Reddy, Yellala V. Rami [1 ]
Ravi, Raminani [2 ]
机构
[1] SV Univ, Dept Chem, Tirupati, AP, India
[2] Govt Degree Coll, Dept Chem, Pakala, AP, India
来源
ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY | 2021年 / 13卷 / 02期
关键词
Dopamine; Uric acid; Phosphomolybdic Acid; Paraphenylenediamine; Carbon paste electrode; REDUCED GRAPHENE OXIDE; ELECTROCHEMICAL DETERMINATION; SIMULTANEOUS ELECTROANALYSIS; FACILE PREPARATION; ASCORBIC-ACID; HYDROQUINONE; CATECHOL; SENSOR; FILM;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A polymerized film of PhosphoMolybdic Acid (PMA)/Poly(Paraphenylene diamine) (PPD) was prepared. The surface of carbon paste electrode was polymerized with the film of PhosphoMolybdic Acid (PMA) and paraphenylenediamine in PBS buffer solution of physiological pH 7.4 by the process of ionic deposition and electro-polymerization. Electrochemical identifications were studied by cyclic voltammetry. This Modified Carbon Paste Electrode (MCPE) was used to investigate DP and UA by CV and DPV techniques, number of parameters affecting the electrocatalytic activity of modified CPE such as effect of pH, scan rate, and concentration were studied. The detection limits of dopamine (DP) and Uric Acid(UA) were calculated by CV as 1.3550 mu M and 4.230 mu M respectively. The high electro catalytic activity of PMA and PPD modified carbon paste electrodes expected to be highly applicable in the field of electro analytical chemistry for the determination of other bio active molecules or neurotransmitters. The modified electrode showed higher sensitivity and selectivity for the simultaneous determination of DP and UA, and fouling effect is also eliminated by this MCPE.
引用
收藏
页码:176 / 189
页数:14
相关论文
共 46 条
[1]  
Avedano S. C., 2007, J ELECTROANAL CHEM, V609, P17
[2]  
Bard A. J., 2001, Electrochemical Methods, Fundamentals and Applications, V2nd
[3]   REDUCTION OF PHOSPHOMOLYBDIC ACID BY COMPOUNDS POSSESSING CONJUGATED DOUBLE BONDS [J].
BURSTEIN, S .
ANALYTICAL CHEMISTRY, 1953, 25 (03) :422-424
[4]   Miceller-Mediated Phosphomolybdic Acid: Highly Effective Reusable Catalyst for Synthesis of Quinoline and Its Derivatives [J].
Chaskar, Atul ;
Padalkar, Vikas ;
Phatangare, Kiran ;
Langi, Bhushan ;
Shah, Chetan .
SYNTHETIC COMMUNICATIONS, 2010, 40 (15) :2336-2340
[5]  
Choukairi M., 2015, J ELECTROANAL CHEM
[6]   Voltammetric resolution of catechol and hydroquinone at eosin Y film modified carbon paste electrode [J].
Ganesh, P. S. ;
Swamy, B. E. Kumara .
JOURNAL OF MOLECULAR LIQUIDS, 2016, 220 :208-215
[7]   Simultaneous electroanalysis of hydroquinone and catechol at poly(brilliant blue) modified carbon paste electrode: A voltammetric study [J].
Ganesh, P. S. ;
Swamy, B. E. Kumara .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 756 :193-200
[8]   Simultaneous electroanalysis of norepinephrine, ascorbic acid and uric acid using poly(glutamic acid) modified carbon paste electrode [J].
Ganesh, P. S. ;
Swamy, B. E. Kumara .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 752 :17-24
[9]  
Ganesh P.S., 2016, SCI LETT J, V5, P236
[10]  
Ganesh P. S., 2014, J. Anal. Bioanal. Tech, V5, P229