Refractive and Visual Outcomes of a Monofocal Non-Constant Aberration Aspheric Intraocular Lens

被引:10
作者
Hernandez-Martinez, Adrian [1 ,2 ]
Diaz-del-Rio, Miguel A. [1 ]
Ruiz-Santos, Maria [1 ]
Ruiz-Mesa, Ramon [1 ]
Tana-Rivero, Pedro [1 ]
机构
[1] Oftalvist Huelva, Ophthalmol Dept, Huelva, Spain
[2] Oftalvist Huelva, Pl Ivonne Cazenave 1, Huelva 21004, Spain
关键词
intraocular lens; phacoemulsification; cataract; aspheric design; aberrations; SPHERICAL-ABERRATION; PERFORMANCE;
D O I
10.2147/OPTH.S373587
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the refractive and visual outcomes following cataract surgery and implantation of a new monofocal non-constant aberration aspheric intraocular lens (IOL).Methods: Ninety eyes of 86 patients who underwent implantation the CT LUCIA 621P IOL (Carl Zeiss Meditec AG) were retrospectively analyzed in this study. Main outcome measures were refractive error and monocular corrected distance visual acuity (CDVA) and monocular uncorrected distance visual acuity (UDVA) values. Patients were evaluated at 1-month post-surgery and intra-and post-operative complications were recorded.Results: Eighty percent of the eyes showed a CDVA of 20/25 or better before surgery. The postoperative mean values of monocular distance Snellen decimal UDVA and CDVA were 0.64 +/- 0.22 and 0.89 +/- 0.13, respectively. All eyes showed the same or better difference between UDVA and CDVA. In relation to the postoperative spherical equivalent, the highest percentage of eyes, 31.11%, was for the range between -0.50 and -0.14D followed by 22.22% for the +/- 0.13D range. Ninety percent of the eyes were within +/- 1.00 D and 73.33% of eyes within +/- 0.50 D. The mean postoperative spherical equivalent was -0.18 +/- 0.55D. 37.78% and 76.67% of the eyes showed a value <0.50 D and <1.00D, respectively, being the mean postoperative refractive cylinder-0.81 +/- 0.50D. No adverse events were reported in whole sample intra and postoperatively.Conclusion: The present study shows that cataract surgery with an monofocal non-constant aberration aspheric IOL implantation resulted in good visual performance and refractive outcomes. This lens may be considered as a valid choice for patients in a standard-routine cataract surgery practice.
引用
收藏
页码:2521 / 2530
页数:10
相关论文
共 22 条
[1]   Optical aberrations of intraocular lenses measured in vivo and in vitro [J].
Barbero, S ;
Marcos, S ;
Jiménez-Alfaro, I .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2003, 20 (10) :1841-1851
[2]   Geometry of Acrylic, Hydrophobic IOLs and Changes in Haptic-Capsular Bag Relationship According to Compression and Different Well Diameters: A Bench Study Using Computed Tomography [J].
Borkenstein, Andreas F. ;
Borkenstein, Eva-Maria .
OPHTHALMOLOGY AND THERAPY, 2022, 11 (02) :711-727
[3]   Surgical experience with a redesigned, fully preloaded, hydrophobic acrylic intraocular lens in challenging cases of pseudoexfoliation syndrome, phacodonesis, and small pupils [J].
Borkenstein, Andreas F. ;
Borkenstein, Eva-Maria .
CLINICAL OPHTHALMOLOGY, 2019, 13 :199-206
[4]   Long-term clinical results and scanning electron microscopic analysis of the aspheric, hydrophobic, acrylic intraocular lens CT LUCIA 611P(Y) [J].
Borkenstein, Andreas F. ;
Borkenstein, Eva-Maria .
CLINICAL OPHTHALMOLOGY, 2018, 12 :1219-1227
[5]   Patient and Surgeon Satisfaction Levels after Using an Acrylic, Hydrophobic, Monofocal IOL and the Malyugin Ring in Pseudoexfoliation Syndrome Patients [J].
Borkenstein, Andreas F. ;
Borkenstein, Eva-Maria .
JOURNAL OF OPHTHALMOLOGY, 2018, 2018
[6]   Surface properties of commercially available hydrophobic acrylic intraocular lenses: Comparative study [J].
De Giacinto, Chiara ;
Porrelli, Davide ;
Turco, Gianluca ;
Pastore, Marco Rocco ;
D'Aloisio, Rossella ;
Tognetto, Daniele .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (09) :1330-1334
[7]   Recent developments in aspheric intraocular lenses [J].
Dick, Hans B. .
CURRENT OPINION IN OPHTHALMOLOGY, 2009, 20 (01) :25-32
[8]   Prospective study to compare axial position stability after fellow-eye implantation of 2 distinct intraocular lens designs [J].
Hienert, Julius ;
Hirnschall, Nino ;
Ruiss, Manuel ;
Ullrich, Marlies ;
Zwickl, Hannah ;
Findl, Oliver .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (08) :999-1005
[9]   Effects of decentration and tilt on the optical performance of 6 aspheric intraocular lens designs in a model eye [J].
Lawu, Tjundewo ;
Mukai, Koichiro ;
Matsushima, Hiroyuki ;
Senoo, Tadashi .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (05) :662-668
[10]   Evaluation of Nd:YAG Laser Capsulotomy Rates in a Real-Life Population [J].
Ling, Roland ;
Borkenstein, Eva-Maria ;
Borkenstein, Andreas F. .
CLINICAL OPHTHALMOLOGY, 2020, 14 :3249-3257