Generation of realistic virtual nodules based on three-dimensional spatial resolution in lung computed tomography: A pilot phantom study

被引:0
作者
Narita, Akihiro [1 ]
Ohkubo, Masaki [1 ]
Murao, Kohei [2 ]
Matsumoto, Toru [3 ]
Wada, Shinichi [1 ]
机构
[1] Niigata Univ, Grad Sch Hlth Sci, Niigata 9518518, Japan
[2] Fujitsu Ltd, Tokyo 448588, Japan
[3] Chiba Kensei Hosp, Chiba 2600032, Japan
关键词
computed tomography (CT); lung nodule; simulation; spatial resolution; virtual nodule; POINT-SPREAD FUNCTION; PULMONARY NODULES; ITERATIVE RECONSTRUCTION; SOFTWARE TOOL; CT; ACCURACY; CHEST; SENSITIVITY; PERFORMANCE; STANDARD;
D O I
10.1002/mp.12503
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this feasibility study using phantoms was to propose a novel method for obtaining computer-generated realistic virtual nodules in lung computed tomography (CT). Methods: In the proposed methodology, pulmonary nodule images obtained with a CT scanner are deconvolved with the point spread function (PSF) in the scan plane and slice sensitivity profile (SSP) measured for the scanner; the resultant images are referred to as nodule-like object functions. Next, by convolving the nodule-like object function with the PSF and SSP of another (target) scanner, the virtual nodule can be generated so that it has the characteristics of the spatial resolution of the target scanner. To validate the methodology, the authors applied physical nodules of 5-, 7- and 10-mm-diameter (uniform spheres) included in a commercial CT test phantom. The nodule-like object functions were calculated from the sphere images obtained with two scanners (Scanner A and Scanner B); these functions were referred to as nodule-like object functions A and B, respectively. From these, virtual nodules were generated based on the spatial resolution of another scanner (Scanner C). By investigating the agreement of the virtual nodules generated from the nodule-like object functions A and B, the equivalence of the nodule-like object functions obtained from different scanners could be assessed. In addition, these virtual nodules were compared with the real (true) sphere images obtained with Scanner C. As a practical validation, five types of laboratory-made physical nodules with various complicated shapes and heterogeneous densities, similar to real lesions, were used. The nodule-like object functions were calculated from the images of these laboratory-made nodules obtained with Scanner A. From them, virtual nodules were generated based on the spatial resolution of Scanner C and compared with the real images of laboratory-made nodules obtained with Scanner C. Results: Good agreement of the virtual nodules generated from the nodule-like object functions A and B of the phantom spheres was found, suggesting the validity of the nodule-like object functions. The virtual nodules generated from the nodule-like object function A of the phantom spheres were similar to the real images obtained with Scanner C; the root mean square errors (RMSEs) between them were 10.8, 11.1, and 12.5 Hounsfield units (HU) for 5-, 7-, and 10-mm-diameter spheres, respectively. The equivalent results (RMSEs) using the nodule-like object function B were 15.9, 16.8, and 16.5 HU, respectively. These RMSEs were small considering the high contrast between the sphere density and background density (approximately 674 HU). The virtual nodules generated from the nodule-like object functions of the five laboratory-made nodules were similar to the real images obtained with Scanner C; the RMSEs between them ranged from 6.2 to 8.6 HU in five cases. Conclusions: The nodule-like object functions calculated from real nodule images would be effective to generate realistic virtual nodules. The proposed method would be feasible for generating virtual nodules that have the characteristics of the spatial resolution of the CT system used in each institution, allowing for site-specific nodule generation. (C) 2017 American Association of Physicists in Medicine
引用
收藏
页码:5303 / 5313
页数:11
相关论文
共 24 条
  • [1] Effect of radiation dose and iterative reconstruction on lung lesion conspicuity at MDCT: Does one size fit all?
    Botelho, Marcos Paulo Ferreira
    Agrawal, Rishi
    Gonzalez-Guindalini, Fernanda Dias
    Hart, Eric M.
    Patel, Suresh K.
    Toere, Hueseyin Guerkan
    Yaghmai, Vahid
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (11) : E726 - E733
  • [2] Results of Initial Low-Dose Computed Tomographic Screening for Lung Cancer
    Church, Timothy R.
    Black, William C.
    Aberle, Denise R.
    Berg, Christine D.
    Clingan, Kathy L.
    Duan, Fenghai
    Fagerstrom, Richard M.
    Gareen, Ilana F.
    Gierada, David S.
    Jones, Gordon C.
    Mahon, Irene
    Marcus, Pamela M.
    Sicks, JoRean D.
    Jain, Amanda
    Baum, Sarah
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2013, 368 (21) : 1980 - 1991
  • [3] Lung Nodule Detection by Microdose CT Versus Chest Radiography (Standard and Dual-Energy Subtracted)
    Ebner, Lukas
    Buetikofer, Yanik
    Ott, Daniel
    Huber, Adrian
    Landau, Julia
    Roos, Justus E.
    Heverhagen, Johannes T.
    Christe, Andreas
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (04) : 727 - 735
  • [4] Application of CT-PSF-based computer-simulated lung nodules for evaluating the accuracy of computer-aided volumetry
    Ayumu Funaki
    Masaki Ohkubo
    Shinichi Wada
    Kohei Murao
    Toru Matsumoto
    Shinji Niizuma
    [J]. Radiological Physics and Technology, 2012, 5 (2) : 166 - 171
  • [5] CT Image Sequence Restoration Based on Sparse and Low-Rank Decomposition
    Gou, Shuiping
    Wang, Yueyue
    Wang, Zhilong
    Peng, Yong
    Zhang, Xiaopeng
    Jiao, Licheng
    Wu, Jianshe
    [J]. PLOS ONE, 2013, 8 (09):
  • [6] Tumor volume measurement error using computed tomography imaging in a phase II clinical trial in lung cancer
    Henschke, Claudia I.
    Yankelevitz, David F.
    Yip, Rowena
    Archer, Venice
    Zahlmann, Gudrun
    Krishnan, Karthik
    Helba, Brian
    Avila, Ricardo
    [J]. JOURNAL OF MEDICAL IMAGING, 2016, 3 (03)
  • [7] Quality assurance and training procedures for computer-aided detection and diagnosis systems in clinical use
    Huo, Zhimin
    Summers, Ronald M.
    Paquerault, Sophie
    Lo, Joseph
    Hoffmeister, Jeffrey
    Armato, Samuel G., III
    Freedman, Matthew T.
    Lin, Jesse
    Lo, Shih-Chung Ben
    Petrick, Nicholas
    Sahiner, Berkman
    Fryd, David
    Yoshida, Hiroyuki
    Chan, Heang-Ping
    [J]. MEDICAL PHYSICS, 2013, 40 (07)
  • [8] Comparison of low-dose and standard-dose helical CT in the evaluation of pulmonary nodules
    Karabulut, N
    Törü, M
    Gelebek, V
    Gülsün, M
    Ariyurek, OM
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (11) : 2764 - 2769
  • [9] A method for evaluating the performance of computeraided detection of pulmonary nodules in lung cancer CT screening: detection limit for nodule size and density
    Kobayashi, Hajime
    Ohkubo, Masaki
    Narita, Akihiro
    Marasinghe, Janaka C.
    Murao, Kohei
    Matsumoto, Toru
    Sone, Shusuke
    Wada, Shinichi
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1070)
  • [10] Lung nodule detection in pediatric chest CT: Quantitative relationship between image quality and radiologist performance
    Li, Xiang
    Samei, Ehsan
    Barnhart, Huiman X.
    Gaca, Ana Maria
    Hollingsworth, Caroline L.
    Maxfield, Charles M.
    Carrico, Caroline W. T.
    Colsher, James G.
    Frush, Donald P.
    [J]. MEDICAL PHYSICS, 2011, 38 (05) : 2609 - 2618