Comparison and appraisal of techniques for the determination of material loss from tapered orthopaedic surfaces

被引:3
作者
Dransfield, Karl [1 ]
Addinall, Katie [1 ]
Bills, Paul [1 ]
机构
[1] Univ Huddersfield, EPSRC Future Adv Metrol Hub, Huddersfield HD1 3DH, W Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
Modular implant; Total joint replacement; Taper measurement; Metal-on-metal; METAL-ON-POLYETHYLENE; LARGE-DIAMETER METAL; TOTAL HIP-ARTHROPLASTY; LOCAL TISSUE REACTION; HEAD-NECK TAPER; RETRIEVAL ANALYSIS; WEAR RATES; CORROSION; STEM; FAILURE;
D O I
10.1016/j.wear.2021.203903
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This review examines the challenges associated with quantifying material loss at modular junctions. Determination of material loss from retrieved orthopaedic surfaces is regarded as a prerequisite for the evaluation of long-term implant performance. Methods previously adopted to overcome the challenges associated with determining material loss from non-articular surfaces will be presented and discussed in this paper. Total Hip Replacement (THR) is regarded as one of the most successful and cost-effective surgical interventions for the treatment of advanced osteoarthritis. The use of modular components offers surgeons an array of possible implant combinations to intraoperatively optimise range of motion and soft tissue tension. However, the taper interface used to connect modular components has been suggested to contribute to premature implant failure through the release of metal debris and corrosion products. Geometrical and topographical measurement of explanted modular interfaces has been used to correlate multifarious variables with an absolute volumetric value for material loss. To improve modular implant performance, medical device manufacturers have adopted numerous design philosophies, each presenting a unique set of challenges for the measurement of material loss. This review summarises the approaches used in previous studies to overcome these challenges and identifies future work required in this area. This field of research is currently the subject of discussion within standards bodies to create recommended best practices for centres to follow.
引用
收藏
页数:16
相关论文
共 105 条
[1]   Is There Material Loss at the Backside Taper in Modular CoCr Acetabular Liners? [J].
Agne, Matthias T. ;
Underwood, Richard J. ;
Kocagoz, Sevi B. ;
MacDonald, Daniel W. ;
Day, Judd S. ;
Parvizi, Javad ;
Kraay, Matthew J. ;
Mont, Michael A. ;
Klein, Gregg R. ;
Cates, Harold E. ;
Kurtz, Steven M. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2015, 473 (01) :275-285
[2]  
Aldinger P., 2015, VALIDATING SIMPLIFIE, P113
[3]  
Ametek, 2014, TALYR 565 585H REV C
[4]  
[Anonymous], 1996, Geometrical product specification (GPS) - Surface texture: profile method
[5]  
surfaces having stratified functional properties -part2: Height characterization using the linear material ratio curve
[6]  
[Anonymous], 2016, ASTM F3129-16
[7]   Microgrooved Surface Topography Does Not Influence Fretting Corrosion of Tapers in Total Hip Arthroplasty: Classification and Retrieval Analysis [J].
Arnholt, Christina ;
Underwood, Richard ;
MacDonald, Daniel W. ;
Higgs, Genymphas B. ;
Chen, Antonia F. ;
Klein, Gregg ;
Hamlin, Brain ;
Lee, Gwo-Chin ;
Mont, Michael ;
Cates, Harlod ;
Malkani, Arthur ;
Kraay, Matthew ;
Rimnac, Clare ;
Kurtz, Steven M. .
MODULARITY AND TAPERS IN TOTAL JOINT REPLACEMENT DEVICES, 2015, 1591 :99-112
[8]   Do Stem Taper Microgrooves Influence Taper Corrosion in Total Hip Arthroplasty? A Matched Cohort Retrieval Study [J].
Arnholt, Christina M. ;
MacDonald, Daniel W. ;
Underwood, Richard J. ;
Guyer, Eric P. ;
Rimnac, Clare M. ;
Kurtz, Steven M. ;
Mont, Michael A. ;
Klein, Gregg R. ;
Lee, Gwo-Chin ;
Chen, Antonia F. ;
Hamlin, Brian R. ;
Cates, Harold E. ;
Malkani, Arthur L. ;
Kraay, Matthew J. .
JOURNAL OF ARTHROPLASTY, 2017, 32 (04) :1363-1373
[9]   Mechanically Assisted Taper Corrosion in Modular TKA [J].
Arnholt, Christina M. ;
MacDonald, Daniel W. ;
Tohfafarosh, Mariya ;
Gilbert, Jeremy L. ;
Rimnac, Clare M. ;
Kurtz, Steven M. ;
Klein, Gregg ;
Mont, Michael A. ;
Parvizi, Javad ;
Cates, Harold E. ;
Lee, Gwo-Chin ;
Malkani, Arthur ;
Kraay, Mattheuw .
JOURNAL OF ARTHROPLASTY, 2014, 29 (09) :205-208
[10]   A large taper mismatch is one of the key factors behind high wear rates and failure at the taper junction of total hip replacements: A finite element wear analysis [J].
Ashkanfar, Ariyan ;
Langton, David J. ;
Joyce, Thomas J. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 69 :257-266