Hyperpolarized Xenon-129 Gas-Exchange Imaging of Lung Microstructure: First Case Studies in Subjects With Obstructive Lung Disease

被引:79
作者
Dregely, Isabel [1 ]
Mugler, John P., III [1 ]
Ruset, Iulian C. [3 ]
Altes, Talissa A. [2 ]
Mata, Jaime F. [2 ]
Miller, G. Wilson [2 ]
Ketel, Jeffrey [3 ]
Ketel, Steve [3 ]
Distelbrink, Jan [3 ]
Hersman, F. W. [1 ,3 ]
Ruppert, Kai [2 ]
机构
[1] Univ New Hampshire, Dept Phys, Durham, NH 03824 USA
[2] Univ Virginia, Sch Med, Ctr In Vivo Hyperpolarized Gas MR Imaging, Dept Radiol, Charlottesville, VA 22908 USA
[3] Xemed LLC, Durham, NH USA
关键词
hyperpolarized xenon-129; gas exchange; lung function; LASER-POLARIZED XE-129; IN-VIVO; MAGNETIC-RESONANCE; HE-3; MRI; EMPHYSEMA; SPECTROSCOPY; DENSITY; XENON; PERFUSION; XTC;
D O I
10.1002/jmri.22533
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop and test a method to noninvasively assess the functional lung microstructure. Materials and Methods: The Multiple exchange time Xenon polarization Transfer Contrast technique (MXTC) encodes xenon gas-exchange contrast at multiple delay times permitting two lung-function parameters to be derived: (i) MXTC-F, the long exchange-time depolarization value, which is proportional to the tissue to alveolar-volume ratio and MXTC-S, the square root of the xenon exchange-time constant, which characterizes thickness and composition of alveolar septa. Three healthy volunteers, one asthmatic, and two chronic obstructive pulmonary disease (COPD) (GOLD stage I and II) subjects were imaged with MXTC MRI. In a subset of subjects, hyperpolarized xenon-129 ADC MRI and CT imaging were also performed. Results: The MXTC-S parameter was found to be elevated In subjects with lung disease (P-value = 0.018). In the MXTC-F parameter map it was feasible to identify regional loss of functional tissue in a COPD patient. MXTC-F maps showed excellent regional correlation with CT and ADC (P >= 0.90) In one COPD subject. Conclusion: The functional tissue-density parameter MXTC-F showed regional agreement with other imaging techniques. The newly developed parameter MXTC-S, which characterizes the functional thickness of alveolar septa, has potential as a novel biomarker for regional parenchymal inflammation or thickening.
引用
收藏
页码:1052 / 1062
页数:11
相关论文
共 40 条
[31]   Emphysema: Hyperpolarized helium 3 diffusion MR imaging of the lungs compared with spirometric indexes - Initial experience [J].
Salerno, M ;
de Lange, EE ;
Altes, TA ;
Truwit, JD ;
Brookeman, JR ;
Mugler, JP .
RADIOLOGY, 2002, 222 (01) :252-260
[32]  
SNIDER GL, 1985, AM REV RESPIR DIS, V132, P182
[33]  
Swanson SD, 1999, MAGNET RESON MED, V42, P1137, DOI 10.1002/(SICI)1522-2594(199912)42:6<1137::AID-MRM19>3.0.CO
[34]  
2-4
[35]   Hyperpolarised 3He MRI versus HRCT in COPD and normal volunteers: PHIL trial [J].
van Beek, E. J. R. ;
Dahmen, A. M. ;
Stavngaard, T. ;
Gast, K. K. ;
Heussel, C. P. ;
Krummenauer, F. ;
Schmiedeskamp, J. ;
Wild, J. M. ;
Sogaard, L. V. ;
Morbach, A. E. ;
Schreiber, L. M. ;
Kauczor, H-U. .
EUROPEAN RESPIRATORY JOURNAL, 2009, 34 (06) :1311-1321
[36]   Cellular and connective tissue changes in alveolar septal walls in emphysema [J].
Vlahovic, G ;
Russell, ML ;
Mercer, RR ;
Crapo, JD .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 160 (06) :2086-2092
[37]   In vivo MR imaging and spectroscopy using hyperpolarized Xe-129 [J].
Wagshul, ME ;
Button, TM ;
Li, HFF ;
Liang, ZR ;
Springer, CS ;
Zhong, K ;
Wishnia, A .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (02) :183-191
[38]  
Weibel ER, 2009, SWISS MED WKLY, V139, P375, DOI smw-12270
[39]  
WEST B, 1972, J APPL PHYSIOL, V32, P332
[40]   Quantitative in vivo assessment of lung microstructure at the alveolar level with hyperpolarized 3He diffusion MRI [J].
Yablonskiy, DA ;
Sukstanskii, AL ;
Leawoods, JC ;
Gierada, DS ;
Bretthorst, GL ;
Lefrak, SS ;
Cooper, JD ;
Conradi, MS .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2002, 99 (05) :3111-3116