Background: Measures should be used to limit radiation exposure of the staff and patients during ERCP. Objective: To determine whether "time-limited fluoroscopy" reduces radiation exposure and fluoroscopy time (FT) compared with continuous fluoroscopy. Design: Prospective randomized trial. Setting: Tertiary academic medical center. Patients: Consecutive adult patients presenting for ERCP. Interventions: Subjects were randomized into 2 fluoroscopy setting groups: (1) time-limited, where x-ray exposure is limited to 3 seconds each time the foot-operated switch is depressed; (2) continuous, where x-ray exposure continues for as long as the switch is depressed. Main Outcomes Measurements: FT, patient, and procedure-related data were recorded. Radiation dosimetry badges were used to estimate cumulative exposure. Results: Ninety-nine procedures were performed in the time-limited group and 100 by using continuous fluoroscopy. The mean FT for time-limited fluoroscopy was 284.4 seconds (95% confidence interval [CI] 247.1-321.6) and for continuous fluoroscopy was 314 seconds (95% CI 265.6-362.4; P = .34). Longer FT was associated with moderate or difficult cannulation (P = .008), lithotripsy (P < .001), stent placement (P = .007), sphincterotomy (P < .001), and longer overall procedure length (P < 0.001). After controlling for confounding factors and interactions with a multiple linear regression model, time-limited fluoroscopy was associated with a 16.4% lower FT (P = .029). The average radiation dose was not amenable to multivariate analysis, and, therefore, no significant difference between groups was found. Limitations: Endoscopists were not blinded to the study group assignments. Conclusions: FT and radiation exposure are dependent upon numerous patient-, operator-, and procedu re related factors. This study found that, after controlling for the impact of confounding factors, time-limited fluoroscopy significantly decreases FTs.
引用
收藏
页码:84 / 89
页数:6
相关论文
共 12 条
[1]   Dose reduction in gastrointestinal and genitourinary fluoroscopy: Use of grid-controlled pulsed fluoroscopy [J].
Boland, GWL ;
Murphy, B ;
Arellano, R ;
Niklason, L ;
Mueller, PR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (05) :1453-1457
[2]   Patient and staff exposure during endoscopic retrograde cholangiopancreatography [J].
Buls, N ;
Pages, J ;
Mana, F ;
Osteaux, M .
BRITISH JOURNAL OF RADIOLOGY, 2002, 75 (893) :435-443
[3]   Practical radiation safety and protection for the endoscopist during ERCP [J].
Campbell, N ;
Sparrow, K ;
Fortier, M ;
Ponich, T .
GASTROINTESTINAL ENDOSCOPY, 2002, 55 (04) :552-557
[4]  
Chen MYM, 1996, GASTROINTEST ENDOSC, V43, P1
[5]   How safe is ERCP to the endoscopist? [J].
Cohen, RV ;
Aldred, MA ;
Paes, WS ;
Fausto, AMF ;
Nucci, JR ;
Yoshimura, EM ;
Okuno, E ;
Garcia, ME ;
Maruta, LM ;
Tolosa, EMC .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1997, 11 (06) :615-617
[6]   Complications of endoscopic biliary sphincterotomy [J].
Freeman, ML ;
Nelson, DB ;
Sherman, S ;
Haber, GB ;
Herman, ME ;
Dorsher, PJ ;
Moore, JP ;
Fennerty, MB ;
Ryan, ME ;
Shaw, MJ ;
Lande, JD ;
Pheley, AM .
NEW ENGLAND JOURNAL OF MEDICINE, 1996, 335 (13) :909-918
[7]  
Johlin FC, 2002, AM J GASTROENTEROL, V97, P893
[8]   Radiation doses to patients during ERCP [J].
Larkin, CJ ;
Workman, A ;
Wright, RER ;
Tham, TCK .
GASTROINTESTINAL ENDOSCOPY, 2001, 53 (02) :161-164
[9]   A review of factors affecting patient doses for barium enemas and meals [J].
Martin, CJ .
BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (922) :864-868
[10]   A study of patient radiation doses in interventional radiological procedures [J].
McParland, BJ .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (842) :175-185