Participant-generated Cochlear Implant Programs: Speech Recognition, Sound Quality, and Satisfaction

被引:7
作者
Dwyer, Robert T. [1 ]
Spahr, Tony [2 ]
Agrawal, Smita [2 ]
Hetlinger, Chris [2 ]
Holder, Jourdan T. [1 ]
Gifford, Rene H. [1 ]
机构
[1] Vanderbilt Univ, Dept Hearing & Speech Sci, 221 Kirkland Hall, Nashville, TN 37235 USA
[2] Adv Bion LLC, Valencia, CA USA
关键词
Cochlear implants; Outcomes; Self-fitting; Self-programming; UNILATERAL DEAFNESS; HEARING; CANDIDACY; EXPANSION; LISTENERS; TINNITUS; LISTS;
D O I
10.1097/MAO.0000000000001076
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To determine whether patient-derived programming of one's cochlear implant (CI) stimulation levels may affect performance outcomes. Background: Increases in patient population, device complexity, outcome expectations, and clinician responsibility have demonstrated the necessity for improved clinical efficiency. Methods: Eighteen postlingually deafened adult CI recipients (mean = 53 years; range, 24-83 years) participated in a repeated-measures, within-participant study designed to compare their baseline listening program to an experimental program they created. Results: No significant group differences in aided sound-field thresholds, monosyllabic word recognition, speech understanding in quiet, speech understanding in noise, nor spectral modulation detection (SMD) were observed (p>0.05). Four ears (17%) improved with the experimental program for speech presented at 45 dB SPL and two ears (9%) performed worse. Six ears (27.3%) improved significantly with the self-fit program at +10 dB signal-to-noise ratio (SNR) and four ears (26.6%) improved in speech understanding at +5 dB SNR. No individual scored significantly worse when speech was presented in quiet at 60 dB SPL or in any of the noise conditions tested. All but one participant opted to keep at least one of the self-fitting programs at the completion of this study. Participants viewed the process of creating their program more favorably (t = 2.11, p = 0.012) and thought creating the program was easier than the traditional fitting methodology (t = 2.12, p = 0.003). Average time to create the self-fit program was 10 minutes, 10 seconds (mean = 9: 22; range, 4: 46-24: 40). Conclusions: Allowing experienced adult CI recipients to set their own stimulation levels without clinical guidance is not detrimental to success.
引用
收藏
页码:E209 / E216
页数:8
相关论文
共 29 条
  • [1] Results With Cochlear Implantation in Adults With Speech Recognition Scores Exceeding Current Criteria
    Amoodi, Hosam A.
    Mick, Paul T.
    Shipp, David B.
    Friesen, Lendra M.
    Nedzelski, Julian M.
    Chen, Joseph M.
    Lin, Vincent Y. W.
    [J]. OTOLOGY & NEUROTOLOGY, 2012, 33 (01) : 6 - 12
  • [2] Comparison of Pseudobinaural Hearing to Real Binaural Hearing Rehabilitation After Cochlear Implantation in Patients With Unilateral Deafness and Tinnitus
    Arndt, Susan
    Aschendorff, Antje
    Laszig, Roland
    Beck, Rainer
    Schild, Christian
    Kroeger, Stefanie
    Ihorst, Gabriele
    Wesarg, Thomas
    [J]. OTOLOGY & NEUROTOLOGY, 2011, 32 (01) : 39 - 47
  • [3] Review: cochlear implants as a treatment of tinnitus in single-sided deafness
    Arts, Remo A. G. J.
    George, Erwin L. J.
    Stokroos, Robert J.
    Vermeire, Katrien
    [J]. CURRENT OPINION IN OTOLARYNGOLOGY & HEAD AND NECK SURGERY, 2012, 20 (05) : 398 - 403
  • [4] Battmer Rolf-Dieter, 2015, Cochlear Implants Int, V16, P100, DOI 10.1179/1754762814Y.0000000093
  • [5] Cochlear Implantation in Nontraditional Candidates: Preliminary Results in Adolescents With Asymmetric Hearing Loss
    Cadieux, Jamie H.
    Firszt, Jill B.
    Reeder, Ruth M.
    [J]. OTOLOGY & NEUROTOLOGY, 2013, 34 (03) : 408 - 415
  • [6] Carlson ML, 2015, OTOL NEUROTOL, V36, P43, DOI 10.1097/MAO.0000000000000607
  • [7] THE ABBREVIATED PROFILE OF HEARING-AID BENEFIT
    COX, RM
    ALEXANDER, GC
    [J]. EAR AND HEARING, 1995, 16 (02) : 176 - 186
  • [8] MINI-MENTAL STATE - PRACTICAL METHOD FOR GRADING COGNITIVE STATE OF PATIENTS FOR CLINICIAN
    FOLSTEIN, MF
    FOLSTEIN, SE
    MCHUGH, PR
    [J]. JOURNAL OF PSYCHIATRIC RESEARCH, 1975, 12 (03) : 189 - 198
  • [9] THE EFFECTS OF DIFFERENT FREQUENCY RESPONSES ON SOUND QUALITY JUDGMENTS AND SPEECH-INTELLIGIBILITY
    GABRIELSSON, A
    SCHENKMAN, BN
    HAGERMAN, B
    [J]. JOURNAL OF SPEECH AND HEARING RESEARCH, 1988, 31 (02): : 166 - 177
  • [10] GABRIELSSON A, 1979, Scandinavian Audiology, V8, P159, DOI 10.3109/01050397909076317