Determination of carcinoembryonic antigen in human sera by integrated bead bed immunoasay in a microchip for cancer diagnosis

被引:303
作者
Sato, K
Tokeshi, M
Kimura, H
Kitamori, T
机构
[1] Univ Tokyo, Sch Engn, Dept Appl Chem, Tokyo 1138656, Japan
[2] Kanagawa Acad Sci & Technol, Integrated Chem Project, Kawasaki, Kanagawa 2130021, Japan
[3] Juntendo Univ, Sch Med, Dept Forens Med, Tokyo 1138421, Japan
关键词
D O I
10.1021/ac000991z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A bead-bed immunoassay system was structured on a microchip and applied to determine carcinoembryonic antigen (CEA), which is a commonly used marker of colon cancer. Polystyrene beads precoated with anti-CEA antibody were introduced into a microchannel, and then a serum sample containing CEA, the first antibody, and the second antibody conjugated with colloidal gold were reacted successively, The resulting antigen-antibodies complex, fixed on the bead surface, was detected using a thermal lens microscope (TLM). A highly elective and sensitive determination of an ultratrace amount of CEA in human sera was made possible by a sandwich immunoassay system that needs three antibodies for an assay. A detection limit dozens of times lower than the conventional ELISA was achieved. Moreover, when serum samples for 13 patients were assayed with this system, there was a high correlation (r = 0.917) with the conventional ELISA. The integration reduced the time necessary for the antigen-antibody reaction to similar to1%, thus shortening the overall analysis time from 45 h to 35 min. Moreover, troublesome operations required for conventional heterogeneous immunoassays could be much simplified. This microchip-based diagnosis system is the first microchip-based system that is practically useful for clinical diagnoses with short analysis time, high sensitivity, and easy procedures.
引用
收藏
页码:1213 / 1218
页数:6
相关论文
共 20 条
[1]   Protein microchips: Use for immunoassay and enzymatic reactions [J].
Arenkov, P ;
Kukhtin, A ;
Gemmell, A ;
Voloshchuk, S ;
Chupeeva, V ;
Mirzabekov, A .
ANALYTICAL BIOCHEMISTRY, 2000, 278 (02) :123-131
[2]  
CHAKRABORTY UR, 1990, ANN BIOL CLIN-PARIS, V48, P403
[3]   Microchip-based capillary electrophoresis for immunoassays: Analysis of monoclonal antibodies and theophylline [J].
Chiem, N ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1997, 69 (03) :373-378
[4]  
Chiem NH, 1998, CLIN CHEM, V44, P591
[5]   Monoclonal antibody binding affinity determined by microchip-based capillary electrophoresis [J].
Chiem, NH ;
Harrison, DJ .
ELECTROPHORESIS, 1998, 19 (16-17) :3040-3044
[6]   Clinical potential of microchip capillary electrophoresis systems [J].
Colyer, CL ;
Tang, T ;
Chiem, N ;
Harrison, DJ .
ELECTROPHORESIS, 1997, 18 (10) :1733-1741
[7]   CONTROLLED NUCLEATION FOR REGULATION OF PARTICLE-SIZE IN MONODISPERSE GOLD SUSPENSIONS [J].
FRENS, G .
NATURE-PHYSICAL SCIENCE, 1973, 241 (105) :20-22
[8]   Quantitation of drug concentration by photo-thermal microscopy in a renal tubule of fixed kidney [J].
Kimura, H ;
Mukaida, M ;
Kitamori, T ;
Sawada, T .
ANALYTICAL SCIENCES, 1997, 13 (05) :729-734
[9]   Ultrasensitive heterogeneous immunoassay using photothermal deflection spectroscopy .2. Quantitation of ultratrace carcinoembryonic antigen in human sera [J].
Kimura, H ;
Matsuzawa, S ;
Tu, CY ;
Kitamori, T ;
Sawada, T .
ANALYTICAL CHEMISTRY, 1996, 68 (17) :3063-3067
[10]   Microchip electrophoretic immunoassay for serum cortisol [J].
Koutny, LB ;
Schmalzing, D ;
Taylor, TA ;
Fuchs, M .
ANALYTICAL CHEMISTRY, 1996, 68 (01) :18-22