SPECMAR: fast heart rate estimation from PPG signal using a modified spectral subtraction scheme with composite motion artifacts reference generation

被引:23
作者
Islam, Mohammad Tariqul [1 ]
Ahmed, Sk. Tanvir [1 ]
Shahnaz, Celia [1 ]
Fattah, Shaikh Anowarul [1 ]
机构
[1] Bangladesh Univ Engn & Technol, Dept Elect & Elect Engn, Dhaka 1205, Bangladesh
关键词
Photoplethysmograph; Spectral subtraction; Motion artifacts removal; Heart rate estimation; PHOTOPLETHYSMOGRAPHIC SIGNALS; REDUCTION;
D O I
10.1007/s11517-018-1909-x
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The task of heart rate estimation using photoplethysmographic (PPG) signal is challenging due to the presence of various motion artifacts in the recorded signals. In this paper, a fast algorithm for heart rate estimation based on modified SPEctral subtraction scheme utilizing Composite Motion Artifacts Reference generation (SPECMAR) is proposed using two-channel PPG and three-axis accelerometer signals. First, the preliminary noise reduction is obtained by filtering unwanted frequency components from the recorded signals. Next, a composite motion artifacts reference generation method is developed to be employed in the proposed SPECMAR algorithm for motion artifacts reduction. The heart rate is then computed from the noise and motion artifacts reduced PPG signal. Finally, a heart rate tracking algorithm is proposed considering neighboring estimates. The performance of the SPECMAR algorithm has been tested on publicly available PPG database. The average heart rate estimation error is found to be 2.09 BPM on 23 recordings. The Pearson correlation is 0.9907. Due to low computational complexity, the method is faster than the comparing methods. The low estimation error, smooth and fast heart rate tracking makes SPECMAR an ideal choice to be implemented in wearable devices.
引用
收藏
页码:689 / 702
页数:14
相关论文
共 20 条
[1]   Photoplethysmography and its application in clinical physiological measurement [J].
Allen, John .
PHYSIOLOGICAL MEASUREMENT, 2007, 28 (03) :R1-R39
[2]   COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1995, 346 (8982) :1085-1087
[3]  
Fu TH, 2008, J MED BIOL ENG, V28, P229
[4]   A review of methods for the signal quality assessment to improve reliability of heart rate and blood pressures derived parameters [J].
Gambarotta, Nicolo ;
Aletti, Federico ;
Baselli, Giuseppe ;
Ferrario, Manuela .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2016, 54 (07) :1025-1035
[5]  
Golyandina N., 2001, ANAL TIME SERIES STR, DOI DOI 10.1201/9780367801687
[6]   Cascade and parallel combination (CPC) of adaptive filters for estimating heart rate during intensive physical exercise from photoplethysmographic signal [J].
Islam, Mohammad Tariqul ;
Ahmed, Sk Tanvir ;
Zabir, Ishmam ;
Shahnaz, Celia ;
Fattah, Shaikh Anowarul .
HEALTHCARE TECHNOLOGY LETTERS, 2018, 5 (01) :18-24
[7]   A time-frequency domain approach of heart rate estimation from photoplethysmographic (PPG) signal [J].
Islam, Mohammad Tariqul ;
Zabir, Ishmam ;
Ahamed, Sk. Tanvir ;
Yasar, Md. Tahmid ;
Shahnaz, Celia ;
Fattah, Shaikh Anowarul .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2017, 36 :146-154
[8]   Heart monitoring systems-A review [J].
Jain, Puneet Kumar ;
Tiwari, Anil Kumar .
COMPUTERS IN BIOLOGY AND MEDICINE, 2014, 54 :1-13
[9]   Motion artifact reduction in photoplethysmography using independent component analysis [J].
Kim, BS ;
Yoo, SK .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (03) :566-568
[10]   Investigation of oesophageal photoplethysmographic signals and blood oxygen saturation measurements in cardiothoracic surgery patients [J].
Kyriacou, PA ;
Powell, S ;
Langford, RM ;
Jones, DP .
PHYSIOLOGICAL MEASUREMENT, 2002, 23 (03) :533-545