Functional analysis in single-lung transplant recipients -: A comparative study of high-resolution CT, 3He-MRI, and pulmonary function tests

被引:43
作者
Zaporozhan, J
Ley, S
Gast, KK
Schmiedeskamp, J
Biedermann, A
Eberle, B
Kauczor, HU
机构
[1] Univ Mainz, Dept Radiol, Mainz, Germany
[2] Univ Mainz, Dept Anesthesiol, Mainz, Germany
[3] Univ Mainz, Dept Pulmonol, Mainz, Germany
[4] Univ Mainz, Inst Phys, Mainz, Germany
关键词
CT; hyperpolarized He-3; MRI; single-lung transplantation; split-lung function;
D O I
10.1378/chest.125.1.173
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To develop and evaluate a postprocessing tool to quantify ventilated split-lung volumes on the basis of He-3-MRI and to apply it in patients after single-lung transplantation (SLTX). High-resolution CT (HRCT) was employed as a reference modality providing split air-filled lung volumes. Lung volumes derived from pulmonary function test results served as clinical parameters and were used as the "gold standard." Material and methods: Eight patients (mean age, 54 years) with emphysema and six patients (mean age, 58 years) with idiopathic pulmonary fibrosis. All patients were evaluated following SLTX. HRCT was performed during inspiration (slice thickness, I mm; increment, 10 mm). For correlation with He-3-MRI, HRCT images were reconstructed In coronal orientation to match the same anatomic levels. Aerated lung was determined by threshold-based segmentation of CT. He-3-MRI was performed on a 1.5-T scanner using a two-dimensional, fast low-angle shot sequence in coronal orientation covering the whole lung after inhalation of a 300-mL bolus of hyperpolarized He-3 gas followed by normal room air for the rest of the tidal volume. Lung segmentation on He-3-MRI was done using different thresholds; Results: In emphysematous patients, He-3-MRI showed excellent correlation (r = 0.9),with vital capacity, while CT correlated (r = 0.8) with total lung capacity. He-3-MRI correlated well with CT (r > 0.8) for grafts and native fibrotic lungs. In emphysematous lungs, MRI showed a good correlation (r = 0.7) with the nonemphysematous lung volume from CT. Increasing thresholds in He-3-MRI reveal differences between aerated and ventilated lung areas with a different distribution in emphysema and fibrosis. Conclusions: He-3-MRI is superior to CT in emphysema to demonstrate ventilated lung areas that participate in gas exchange. In fibrosis, He-3-MRI and CT have a similar impact. The decrease pattern and the intraindividual ratio between ventilation of native and transplanted lungs will have to be investigated as a new surrogate for the ventilatory follow-up in patients undergoing SLTX.
引用
收藏
页码:173 / 181
页数:9
相关论文
共 32 条
  • [1] LIMITATIONS OF SPIROMETRY IN DETECTING REJECTION AFTER SINGLE-LUNG TRANSPLANTATION
    BECKER, FS
    MARTINEZ, FJ
    BRUNSTING, LA
    DEEB, GM
    FLINT, A
    LYNCH, JP
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1994, 150 (01) : 159 - 166
  • [2] Automated measurement of single and total lung volume from CT
    Brown, MS
    McNitt-Gray, MF
    Goldin, JG
    Greaser, LE
    Hayward, UM
    Sayre, JW
    Arid, MK
    Aberle, DR
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (04) : 632 - 640
  • [3] Knowledge-based segmentation of thoracic computed tomography images for assessment of split lung function
    Brown, MS
    Goldin, JG
    McNitt-Gray, MF
    Greaser, LE
    Sapra, A
    Li, KT
    Sayre, JW
    Martin, K
    Aberle, DR
    [J]. MEDICAL PHYSICS, 2000, 27 (03) : 592 - 598
  • [4] Imaging of the chest after lung transplantation
    Collins, J
    [J]. JOURNAL OF THORACIC IMAGING, 2002, 17 (02) : 102 - 112
  • [5] Lung transplantation at the turn of the century
    DeMeo, DL
    Ginns, LC
    [J]. ANNUAL REVIEW OF MEDICINE, 2001, 52 : 185 - 201
  • [6] A DENSE POLARIZED HE-3 TARGET BASED ON COMPRESSION OF OPTICALLY PUMPED GAS
    ECKERT, G
    HEIL, W
    MEYERHOFF, M
    OTTEN, EW
    SURKAU, R
    WERNER, M
    LEDUC, M
    NACHER, PJ
    SCHEARER, LD
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 320 (1-2) : 53 - 65
  • [7] Volume of graft and native lung after single-lung transplantation for emphysema
    Estenne, M
    Cassart, M
    Poncelet, P
    Gevenois, PA
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (02) : 641 - 645
  • [8] MRI in lung transplant recipients using hyperpolarized 3He:: Comparison with CT
    Gast, KK
    Viallon, M
    Eberle, B
    Lill, J
    Puderbach, MU
    Hanke, AT
    Schmiedeskamp, J
    Kauczor, HU
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (03) : 268 - 274
  • [9] Comparison of computed density and microscopic morphometry in pulmonary emphysema
    Gevenois, PA
    DeVuyst, P
    deMaertelaer, V
    Zanen, J
    Jacobvitz, D
    Cosio, MG
    Yernault, JC
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1996, 154 (01) : 187 - 192
  • [10] COMPARISON OF COMPUTED DENSITY AND MACROSCOPIC MORPHOMETRY IN PULMONARY-EMPHYSEMA
    GEVENOIS, PA
    DEMAERTELAER, V
    DEVUYST, P
    ZANEN, J
    YERNAULT, JC
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1995, 152 (02) : 653 - 657